1.

 

Enter Programming Mode by entering the Master Code twice. The LED will turn yellow.  
(Default Master Code is 1234). 

2.

 

Enter              . The LED will flash yellow. 

3.

 

Enter the new Master Code twice. The keypad will sound 2 short beeps. The Master Code may not be 
the same as a user code. 

Example: If the desired new Master Code is 4321, enter:                                                    . 
4.

 

Exit Programming Mode by pressing       . 
     

1.

 

Enter Programming Mode by entering the Master Code twice. The LED will turn yellow. 
(Default Master Code is 1234). 

2.

 

Enter                          . The keypad will sound 2 short beeps and the LED will flash yellow. 

3.

 

Enter the desired code length. This must be a number from 2~6. The keypad will sound 2 short beeps 
followed by 6 short beeps and 1 long beep. 

4.

 

Exit Programming Mode by pressing       . 

 

 

Program a new Master Code immediately. 

 

Take note of the keypad status LED— 

o

 

Solid Blue: Standby Mode 

o

 

Solid Yellow: Programming Mode 

o

 

Flashing Green: Awaiting code/card entry 

 

If you are unsure of which mode the keypad is in, press       until the LED is blue. The keypad is now in the 
Standby Mode. Enter the master code twice to return to Programming Mode. 

Enter: 

1.

 

Codes are programmed to be 2~6 digits in length. All codes must be the same length. 

2.

 

Before inputting any of the following, enter Programming Mode by entering the  
Master Code twice. 
The default Master Code is 1234.  
To enter Programming Mode, enter                                                          . 

3.

 

To exit Programming Mode, press      . 

4.

 

The keypad will exit Programming Mode if no keys are pressed for 30 seconds. 

Programming Instructions: 

Programming Tips: 

First Time Keypad Use: 

Take these steps the first time the keypad is programmed. 

C.

 

Program the Master Code 

A.

 

Enter Programming Mode 

 

(Default Master Code is 1234). 

B.

 

Program Code Length 

 

WARNING: After a new code length is programmed, all user codes will be deleted and master code will 
be reset. 
     

NOTE: The Master Code will reset depending on the programmed code length. These will be the new  

Master Codes after the code length is reset: 

 

Code Length 

New Master Code 

2 digits 

12 

3 digits 

123 

4 digits 

1234 

 

Code Length 

New Master Code 

5 digits 

12345 

6 digits 

123456 

 

2  3 

1  2 

3  4 

2  3 

1  2 

3  4 

 

9  0  4 

4  3  2  1  4  3  2  1 

NOTE: To keep the default 4-digit code length, skip to step C, Program the Master Code

 

Summary of Contents for SK-2323-SDAQ

Page 1: ...DAQ SK 2323 SPAQ SK 2323 SPAQ shown 12 24 VAC VDC operation 2 Form C relays 1A 30VDC Piezoelectric keys with no moving parts for heavy duty use Optical tamper for added security Backlit keys for easy...

Page 2: ...oz 150g Proximity reader frequency SK 2323 SPAQ only 125kHz Proximity reader distance SK 2323 SPAQ only 2 5cm Sample Wiring and Applications 6 7 User Control Chart 8 9 Programming Instructions 10 13...

Page 3: ...r on standby mode Yellow Programming mode Green Waiting to program code card code card access mode Red Code card already present Green Relay 1 activated Red Relay 2 activated Green Both relays activat...

Page 4: ...Basic keypad functions are located on pg 16 of this manual Be sure to store this manual in a safe place for future reference 5 If using VAC use the Green Common Ground wire for all sensor input Wirin...

Page 5: ...ace If mounting to brick or drywall it may be necessary to use the included screw anchors 6 If the installation is using surface wiring mount the keypad to a single gang box using the 2 single gang bo...

Page 6: ...lectromagnetic locks 2 Output 2 can control the arm disarm of the alarm control panel Consult the alarm control panel manual for more information Connecting to a Doorbell Purple Output 2 COM Blue Outp...

Page 7: ...nnect diode or MOV when using electromagnetic locks Door Sensing Brown Door Sensing Input N C Green Common ground For N O Locking Devices Purple Output 2 COM Pink Output 1 COM Blue Output 2 N O White...

Page 8: ...ENFORCER Piezoelectric Mullion Style Outdoor Stand Alone Keypads 8 SECO LARM U S A Inc...

Page 9: ...ENFORCER Piezoelectric Mullion Style Outdoor Stand Alone Keypads SECO LARM U S A Inc 9 SEC...

Page 10: ...s in press until the LED is blue The keypad is now in the Standby Mode Enter the master code twice to return to Programming Mode Enter 1 Codes are programmed to be 2 6 digits in length All codes must...

Page 11: ...EFAULT User card AND user code The keypad will sound 2 short beeps and the LED will turn yellow NOTE Deleting all users is recommended before changing the access mode to user card AND user code See pg...

Page 12: ...repeat from step 2 in section A or B 5 Return to Programming Mode by pressing 6 Exit Programming Mode by pressing again 1 Enter a user ID number to The LED will turn green 2 If the LED is red previous...

Page 13: ...o activate doorbell Doorbell output lasts 1 second DEFAULT User codes 0 1 0 2 Step 1 Step 2 or Enter For user codes enter For doorbell enter Output 2 can be activated via or through user codes Use the...

Page 14: ...Code Length 4 digits Master Code 1234 Output 1 Access Mode User codes OR user cards Output 1 User Codes None Output 2 User Codes None Output 1 Timer 1 second Output 2 Timer 1 second Output 2 Function...

Page 15: ...If it is red previous user data exists Press to delete The keypad will not program a new Master Card Before inputting new code or card check the LED If it is solid green a Master Card is already prog...

Page 16: ...de Deleting an Output 1 user Enter a 3 digit user ID from 000 999 Enter Deleting an Output 2 user Enter 4 Enter a 2 digit user ID from 00 09 Enter Set Output 1 timer Enter 1 Enter number of seconds fr...