background image

ENFORCER

 Piezoelectric Mullion-Style Outdoor Stand-Alone Keypads

 
 

SECO-LARM U.S.A., Inc                                                                                    11

 

SECO-LARM U.S.A., Inc.                                                                                                  

               33                                              11                                                                                         

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.

 

Enter a user ID number   (                   to                   ). The LED will turn green. 

2.

 

If the LED is red, previous user data exists. Clear it by entering             . The keypad will beep in 
confirmation and the LED will turn green. 

3.

 

Swipe a new user card. The keypad will sound 1 short and 1 long beep and the LED will remain green. 

4.

 

Return to Programming Mode by pressing       . 

NOTE: Must return to Programming Mode after learning a card, otherwise user will overwrite existing card. 
5.

 

To program the next user, repeat from step 1 in section A, B, or C. 

6.

 

Exit Programming Mode by pressing        again. 

 

1.

 

Enter a user ID number   (                   to                   ). The LED will turn green. 

2.

 

If the LED is red, previous user data exists. Clear it by entering             . The keypad will beep in 
confirmation and the LED will turn green. 

3.

 

Enter a new user code. The keypad will sound 2 short beeps and the LED will turn yellow. 

4.

 

To program the next user, repeat from step 1 in section A, B, or C. 

5.

 

Exit Programming Mode by pressing       . 

1.

 

Enter Programming Mode by entering the Master Code twice. The LED will turn yellow. 

2.

 

Enter              . The LED will flash yellow. 

3.

 

Enter one of the following: 

User card ONLY 
Either user card OR user code (DEFAULT) 
User card AND user code 

The keypad will sound 2 short beeps and the LED will turn yellow. 

NOTE: Deleting all users is recommended before changing the access mode to user card AND user code. 

See pg. 14, Deleting All Users.  

4.

 

Exit Programming Mode by pressing       .    

 

1.

 

Enter Programming Mode by entering the Master Code twice. The LED will turn yellow.  
(Default Master Code is 1234

2.

 

Enter             . The LED will flash green. 

3.

 

If the LED is solid green, a Master Card is already programmed. Clear it by entering             . 
The keypad will sound 2 short beeps in confirmation and the LED will start flashing green. 

4.

 

Swipe a proximity card (PR-K1S1A or similar). The keypad will sound 2 short beeps and the LED will 
turn yellow. This card is now the Master Card. 

5.

 

Exit Programming Mode by pressing       . 

Programming Output #1: 

E.

 

Setting the Output #1 Access Mode* 

DEFAULT: User card OR user code.  

0  0 
0  1 

0  2 

Each Output #1 user can be programmed to have a user code, a user card, or both a user code and card.* 

A.

 

Programming User Codes 

NOTE:  For all of the following programming functions, the keypad must be in Programming Mode. To enter 

Programming Mode, enter the Master Code twice or swipe the Master Card. 

*SK-2323-SPAQ only. 

D.

 

Program the Master Card (SK-2323-SPAQ only) 

In addition to a Master Code, a Master Card can also be programmed. Swiping a Master Card will give 
direct access to Programming Mode. 

B.

 

Programming User Cards* 

 

   

 

   

   

0  0  0 

9  9  9 

0  0  0 

9  9  9 

Summary of Contents for SK-2323-SDAQ

Page 1: ...DAQ SK 2323 SPAQ SK 2323 SPAQ shown 12 24 VAC VDC operation 2 Form C relays 1A 30VDC Piezoelectric keys with no moving parts for heavy duty use Optical tamper for added security Backlit keys for easy...

Page 2: ...oz 150g Proximity reader frequency SK 2323 SPAQ only 125kHz Proximity reader distance SK 2323 SPAQ only 2 5cm Sample Wiring and Applications 6 7 User Control Chart 8 9 Programming Instructions 10 13...

Page 3: ...r on standby mode Yellow Programming mode Green Waiting to program code card code card access mode Red Code card already present Green Relay 1 activated Red Relay 2 activated Green Both relays activat...

Page 4: ...Basic keypad functions are located on pg 16 of this manual Be sure to store this manual in a safe place for future reference 5 If using VAC use the Green Common Ground wire for all sensor input Wirin...

Page 5: ...ace If mounting to brick or drywall it may be necessary to use the included screw anchors 6 If the installation is using surface wiring mount the keypad to a single gang box using the 2 single gang bo...

Page 6: ...lectromagnetic locks 2 Output 2 can control the arm disarm of the alarm control panel Consult the alarm control panel manual for more information Connecting to a Doorbell Purple Output 2 COM Blue Outp...

Page 7: ...nnect diode or MOV when using electromagnetic locks Door Sensing Brown Door Sensing Input N C Green Common ground For N O Locking Devices Purple Output 2 COM Pink Output 1 COM Blue Output 2 N O White...

Page 8: ...ENFORCER Piezoelectric Mullion Style Outdoor Stand Alone Keypads 8 SECO LARM U S A Inc...

Page 9: ...ENFORCER Piezoelectric Mullion Style Outdoor Stand Alone Keypads SECO LARM U S A Inc 9 SEC...

Page 10: ...s in press until the LED is blue The keypad is now in the Standby Mode Enter the master code twice to return to Programming Mode Enter 1 Codes are programmed to be 2 6 digits in length All codes must...

Page 11: ...EFAULT User card AND user code The keypad will sound 2 short beeps and the LED will turn yellow NOTE Deleting all users is recommended before changing the access mode to user card AND user code See pg...

Page 12: ...repeat from step 2 in section A or B 5 Return to Programming Mode by pressing 6 Exit Programming Mode by pressing again 1 Enter a user ID number to The LED will turn green 2 If the LED is red previous...

Page 13: ...o activate doorbell Doorbell output lasts 1 second DEFAULT User codes 0 1 0 2 Step 1 Step 2 or Enter For user codes enter For doorbell enter Output 2 can be activated via or through user codes Use the...

Page 14: ...Code Length 4 digits Master Code 1234 Output 1 Access Mode User codes OR user cards Output 1 User Codes None Output 2 User Codes None Output 1 Timer 1 second Output 2 Timer 1 second Output 2 Function...

Page 15: ...If it is red previous user data exists Press to delete The keypad will not program a new Master Card Before inputting new code or card check the LED If it is solid green a Master Card is already prog...

Page 16: ...de Deleting an Output 1 user Enter a 3 digit user ID from 000 999 Enter Deleting an Output 2 user Enter 4 Enter a 2 digit user ID from 00 09 Enter Set Output 1 timer Enter 1 Enter number of seconds fr...

Reviews: