background image

ENFORCER

 Piezoelectric Mullion-Style Outdoor Stand-Alone Keypads

 

12

 

                                                        

SECO-LARM U.S.A., Inc.

 

 

 

 

 

 

 

 

 

 

 

1.

 

Enter             

        

. The LED will flash yellow. 

2.

 

Enter a user ID number. (             to             ). The LED will turn green. 

3.

 

If the LED is red, previous user data exists. Clear it by entering             . The keypad will beep in 
confirmation and the LED will turn green. 

4.

 

Swipe a new user card. The keypad will sound 2 short beeps and the LED will turn yellow. 

5.

 

To program the next user, repeat from step 2 in section A or B. 

6.

 

Return to Programming Mode by pressing       . 

7.

 

Exit Programming Mode by pressing       again. 

NOTE:  If a user card previously programmed for Output #1 is later programmed for Output #2, it will no 

longer operate for Output # 1. However, Output # 1 cannot receive another user card unless it is 
first cleared. 

1.

 

Enter             . The LED will flash yellow. 

2.

 

Enter a user ID number. (             to             ). The LED will turn green. 

3.

 

If the LED is red, previous user data exists. Clear it by entering             . The keypad will beep in 
confirmation and the LED will turn green. 

6.

 

Enter a new user code. The keypad will sound 2 short beeps and the LED will turn yellow. 

4.

 

To program the next user, repeat from step 2 in section A or B. 

5.

 

Return to Programming Mode by pressing      . 

6.

 

Exit Programming Mode by pressing       again. 

1.

 

Enter a user ID number (                   to                   ). The LED will turn green. 

2.

 

If the LED is red, previous user data exists. Clear it by entering              . The keypad will beep in 
confirmation and the LED will turn green. 

3.

 

Swipe a new user card. The keypad will sound 1 short and 1 long beep in confirmation and the LED will 
remain green. 

4.

 

Enter a new user code. The keypad will sound 2 short beeps in confirmation and the LED will turn yellow. 

5.

 

To program the next user, repeat from step 1 in section A, B, or C. 

6.

 

Exit Programming Mode by pressing       . 

 

Deleting or Changing the Master Card* 

Programming Output #2: 

Each Output #2 user may only have a user code OR a user card programmed. 

*SK-2323-SPAQ only. 

NOTE:  For all of the following programming functions, the keypad must be in Programming Mode. To enter 

Programming Mode, enter the Master Code twice or swipe the Master Card. 

Continued from pg. 11. 

B.

 

Programming an Output #2 User Card* 

A.

 

Programming an Output #2 User Code 

0  0 

0  9 

Deleting or Changing Users and Cards: 

Enter: 

Step 1 

Step 2 

Step 3 

Delete the existing Master Card by entering: 

Swipe a new Master Card. 

or 

Exit Programming Mode by entering        . 

0  0 

0  9 

 

 

 

 

   

 

   

   

C.

 

Programming Both User Codes and Cards* 

0  0  0 

9  9  9 

Summary of Contents for SK-2323-SDAQ

Page 1: ...DAQ SK 2323 SPAQ SK 2323 SPAQ shown 12 24 VAC VDC operation 2 Form C relays 1A 30VDC Piezoelectric keys with no moving parts for heavy duty use Optical tamper for added security Backlit keys for easy...

Page 2: ...oz 150g Proximity reader frequency SK 2323 SPAQ only 125kHz Proximity reader distance SK 2323 SPAQ only 2 5cm Sample Wiring and Applications 6 7 User Control Chart 8 9 Programming Instructions 10 13...

Page 3: ...r on standby mode Yellow Programming mode Green Waiting to program code card code card access mode Red Code card already present Green Relay 1 activated Red Relay 2 activated Green Both relays activat...

Page 4: ...Basic keypad functions are located on pg 16 of this manual Be sure to store this manual in a safe place for future reference 5 If using VAC use the Green Common Ground wire for all sensor input Wirin...

Page 5: ...ace If mounting to brick or drywall it may be necessary to use the included screw anchors 6 If the installation is using surface wiring mount the keypad to a single gang box using the 2 single gang bo...

Page 6: ...lectromagnetic locks 2 Output 2 can control the arm disarm of the alarm control panel Consult the alarm control panel manual for more information Connecting to a Doorbell Purple Output 2 COM Blue Outp...

Page 7: ...nnect diode or MOV when using electromagnetic locks Door Sensing Brown Door Sensing Input N C Green Common ground For N O Locking Devices Purple Output 2 COM Pink Output 1 COM Blue Output 2 N O White...

Page 8: ...ENFORCER Piezoelectric Mullion Style Outdoor Stand Alone Keypads 8 SECO LARM U S A Inc...

Page 9: ...ENFORCER Piezoelectric Mullion Style Outdoor Stand Alone Keypads SECO LARM U S A Inc 9 SEC...

Page 10: ...s in press until the LED is blue The keypad is now in the Standby Mode Enter the master code twice to return to Programming Mode Enter 1 Codes are programmed to be 2 6 digits in length All codes must...

Page 11: ...EFAULT User card AND user code The keypad will sound 2 short beeps and the LED will turn yellow NOTE Deleting all users is recommended before changing the access mode to user card AND user code See pg...

Page 12: ...repeat from step 2 in section A or B 5 Return to Programming Mode by pressing 6 Exit Programming Mode by pressing again 1 Enter a user ID number to The LED will turn green 2 If the LED is red previous...

Page 13: ...o activate doorbell Doorbell output lasts 1 second DEFAULT User codes 0 1 0 2 Step 1 Step 2 or Enter For user codes enter For doorbell enter Output 2 can be activated via or through user codes Use the...

Page 14: ...Code Length 4 digits Master Code 1234 Output 1 Access Mode User codes OR user cards Output 1 User Codes None Output 2 User Codes None Output 1 Timer 1 second Output 2 Timer 1 second Output 2 Function...

Page 15: ...If it is red previous user data exists Press to delete The keypad will not program a new Master Card Before inputting new code or card check the LED If it is solid green a Master Card is already prog...

Page 16: ...de Deleting an Output 1 user Enter a 3 digit user ID from 000 999 Enter Deleting an Output 2 user Enter 4 Enter a 2 digit user ID from 00 09 Enter Set Output 1 timer Enter 1 Enter number of seconds fr...