ENFORCER
Piezoelectric Mullion-Style Outdoor Stand-Alone Keypads
14
SECO-LARM U.S.A., Inc.
*SK-2323-SPAQ only.
Resetting the Keypad:
NOTE: Resetting the keypad will cause some or all programmed data to be lost. Do not
perform either of these steps unless it is absolutely necessary.
Deleting All Users:
Enter:
8 8 8
IMPORTANT: Once key entry is made, all user codes and user cards will be deleted and the keypad will return to
Programming Mode. The Master Code and all other programming settings will remain the same. To restore factory settings,
see Restore Factory Settings below.
Restore Factory Settings:
Enter:
8 9 9
IMPORTANT: Once key entry is made, keypad will return to factory default settings. No user information will be retained
and the Master Code will be 1234. For SK-2323-SPAQ, Output #1 Access Mode will be set to user codes or user cards.
Factory Defaults:
Code Length
4 digits
Master Code
1234
Output #1 Access Mode*
User codes OR user cards
Output #1 User Codes
None
Output #2 User Codes
None
Output #1 Timer
1 second
Output #2 Timer
1 second
Output #2 Function
User codes
Tamper Alarm
OFF
Manually Resetting the Master Code:
If the Master Code has been forgotten or does not work, the following steps can be taken to reset the Master
Code:
1.
Disconnect power from the keypad.
2.
Reconnect power. The LED will flash green 8 times.
3.
While the LED is flashing green, press .
4.
At this time, the Master Code has successfully been reset.
#
NOTE: Manually resetting the Master Code will only reset the Master Code. It will not affect the Master Card,
User Codes/Cards*, or any other saved data. To delete the Master Card, see pg. 12, Deleting or
Changing the Master Card.
NOTE: The Master Code will reset depending on the programmed code length. These will be the new Master
Codes after the code length is reset:
Code Length
New Master Code
2 digits
12
3 digits
123
4 digits
1234
Code Length
New Master Code
5 digits
12345
6 digits
123456