7.9 XForce thruster cable, fuse and battery requirements
XForce
Thruster
Motor
V/kW
Thrust
(KG)
Maximum cable length
1)
Minimum cable dimension
Required min.
battery capacity
Rec.
fuse
amp.
Spare fuse
P/N
Length m/ft
Dim.
2)
mm
2
-AWG
Ah/V
CCA
(SAE)
XF20
12/1.1 20
1-5/1-16
50-1/0
50 Ah/12 V
550
200
12-00200
XF40
12/2
40
1-4/1-13
4-8/13-26
50-1/0
70-2/0
100 Ah/12 V
800
300
12-00300
XF60
12/4
60
1-10/1-33
10-20/33-67
95-3/0
120-4/0
100 Ah/12 V
800
350
12-00350
XF60
24/4
60
1-10/1-33
10-20/33-67
95-3/0
95-3/0
100 Ah/24 V
800
300
12-00300
XF75
12/4
75
1-10/1-33
10-20/33-67
95-3/0
120-4/0
100 Ah/12 V
800
400
12-00400
XF75
24/4
75
1-10/1-33
10-20/33-67
95-3/0
95-3/0
150 Ah/24 V
1050
350
12-00350
XF90
12/4
90
1-10/1-33
10-20/33-67
95-3/0
120-4/0
100 Ah/12 V
800
400
12-00400
XF90
24/4
90
1-10/1-33
10-20/33-67
95-3/0
95-3/0
150 Ah/24 V
1050
350
12-00350
XF130
24/7
130
1-10/1-33
120-4/0
175 Ah/24 V
1150
400
12-00400
1
) The distance from the thruster unit to the battery, one way, each cable.
Use of even larger cable dimensions and battery capacity will give the thrusters better performance.
2) Wiring insulation rating is 105°C (221°F) minimum.
Summary of Contents for XForce Series
Page 24: ...XF Rev 5 2008 10 06 Side 24 6 11 Elektriske kobling skjemaer 6 11 1 XForce 20 ...
Page 25: ...XF Rev 5 2008 10 06 Side 25 6 11 2 XForce 40 60 75 90 130 ...
Page 32: ......
Page 56: ...XF Rev 7 2008 10 14 Page 24 7 10 Wiring diagrams 7 10 1 XForce 20 ...
Page 57: ...XF Rev 7 2008 10 14 Page 25 7 10 2 XForce 40 60 75 90 130 ...
Page 64: ......