6 Maintenance
REMARKS
Install the tapered
face seal with
a narrow edge
outward.
Figure 24.
6.4. Lubrication every 8 operating hours
Your product is fitted with single-point lubrication of progressive type.
The lubricant distribution block with grease nipple is mounted on the tilt cylinder side of the
tiltrotator.
The integrated grab and quick hitch beneath the tiltrotator have their own grease points
and are not connected to the lubrication system. See the relevant images for lubrication
points for the quick hitch and integrated grab beneath the tiltrotator. During refilling, a
certain amount of spillage may occur between the body and the hitch's ring.
Blockage in one grease channel will entail blockage of the entire lubrication system. For
troubleshooting, contact your service partner or engcon Nordic AB.
Grease recommendation:
On delivery, we fill your product with our recommended universal mineral oil-based grease
with an EP additive, a lithium soap thickener and a hardness of (NLGI) 2. In severe cold
we recommend hardness (NLGI) 1.
IMPORTANT
Do not use greases containing solid particles such as
molybdenum, graphite or copper. Such particles can lead to
failure of the lubrication block.
IMPORTANT
Ensure the highest possible cleanliness when greasing or
connecting the lubrication system. The lubrication system is
sensitive to dirt.