6 Maintenance
6.3.2. Extension plates PP3200
The PP3200 can be equipped with levelling
blades and extension plates. These are
installed as illustrated.
986404
Figure 7.
6.4. Oil change
Change the generator oil annually with 10w/30 mineral oil. Oil quantity: 0.05 gal.
6.5. Tightening torque
Top bracket
Type
Dimension
Quality
Quantity
Torque
PP3200
M16
8.8
12
145 lb-ft
PP350
M16
8.8
8
145 lb-ft
PP600
M16
8.8
8
145 lb-ft
PP950
M16
8.8
8
145 lb-ft
Table 1.
EC-Oil hydraulic connectors
Type
Fastener
Quantity
Torque
ECO45/50/60/70
Hydraulic connector
ECO
2
44 lb-ft
Table 2.