TROUBLE SHOOTING
Fault
Possible cause
Action
Compressor not
working
No power supplied
Battery in poor condition.
Faulty electronic unit.
Electronic unit failure
Check if power is supplied to
electronic unit.
Check fuse.
Check polarity of connectors and
cables.
Interior not cold
Ambient temperature too high.
Insufficient ventilation Frost on
evaporator
Condenser clogged
Keep refrigerator sufficiently
ventilated.
Defrost evaporator.
Clean condenser.
Error message will be displayed if the voltage of the battery is low or in the event of
any malfunctions- (see next table).
When error message is displayed, the unit will be on “standby mode”. Operations
will stop.
ERROR CODE
DESCRIPTION
SOLUTIONS
DOT INDICATION
Push “MODE” button
⇒
E-01 and current
voltage display
Abnormal Input Voltage
Check whether the power
voltage is too low.
E-04
Ambient Temperature is too low
Check whether the ambient
temperature is too low.
E-05
Temperature sensor cord is shorted
Contact service agent.
E-06
Temperature sensor cord is open
Contact service agent.
E-07
Abnormal Input Voltage(too high)
Check whether the power
voltage is too high.
Table
If the problem still persists after going through the chart above, consult an ENGEL
service agent or dealer near you.
Never disassemble the refrigerator by yourself. Inadequate repairs can lead to