3.3.4.5

 

Energy budget 

Here you can see the energy code in % for the current settings. 

Calculation: adjusted annual consumption / maximum permissible annual consumption * 100 

The display is updated every time the "Read" button is pushed.  

Furthermore every time “Read” or “Write” button of the previous timing settings are pushed the displayed 
value is updated. 

Values  <   100% are set in the Gateway 

Values    >=   100% are not accepted by the Gateway 

 

Energy budget > 100% are only possible with mains power supply. 

 

 

 

Summary of Contents for Gateway

Page 1: ...sor GmbH Rudolf Diesel Straße 24 28 D 69168 Wiesloch Baiertal Germany Page 1 of 23 Manual Gateway Device Monitor Version V 1 2 2018_07_10 Subject to technical change Manual Gateway Configuration with Device Monitor ...

Page 2: ...BASIC STRUCTURE OF THE USER INTERFACE IN THE DEVICE MONITOR 10 3 3 SETUP 11 3 3 1 Main config 11 3 3 1 1 GSM settings 11 3 3 1 2 GSM status 11 3 3 1 3 Time settings 11 3 3 2 Data transfer 12 3 3 2 1 FTP settings 12 3 3 2 2 Email settings 12 3 3 2 3 SMTP settings 12 3 3 2 4 Upload file format setting 13 3 3 2 5 Estate settings file name 13 3 3 3 Device handling 14 3 3 3 1 Wireless M Bus settings 14...

Page 3: ... D 69168 Wiesloch Baiertal Germany Page 3 of 23 Manual Gateway Device Monitor Version V 1 2 2018_07_10 Subject to technical change 3 5 INFORMATION 22 3 5 1 Gateway Information 22 3 5 1 1 Energy state 22 3 5 1 2 Energy budget 22 3 5 1 3 Error flags 23 ...

Page 4: ...mory of the Gateway 2 Decode AES and format file format the data from non volatile FLASH memory and upload the output to an FTP Server 3 Decode AES and format file format the data from non volatile FLASH memory and send the output via an SMTP server to an E mail box 4 Wait a certain time for configuration massages SMS progress them and send out an answer 1 3 Configuration of the Gateway The Gatewa...

Page 5: ... APN Access Point Name NTP Network Time Protocol SMTP Simple Mail Transfer Protocol CSV Character Separated Values XML Extensible Markup Language AES Advanced Encryption Standard a symmetrical crypt system cryptographic technique RSSI Received Signal Strength Indicator RSSI Is an indicator of the reception field intensity of wireless communication applications RAW Raw data format IP Internet Proto...

Page 6: ...ription 1 Internal wireless M Bus antenna 10 GSM GPRS antenna connector 2 External wireless M Bus antenna connector 11 Power supply connector 3 Wireless M Bus module 12 Battery connectors 4 Status LED 13 Batteries 5 Non volatile memory 14 Micro USB configuration 6 Processor 15 Antenna adapter GSM GPRS optional 7 SIM card holder 16 Antenna adapter wM Bus optional 8 GSM GPRS modem IMEI number 17 Ser...

Page 7: ...ond 4 Collect Short flash every 15 seconds 5 SMS receiving Flash every second 6 FTP Upload Short flash every 15 seconds 7 SMTP Upload Short flash every 5 seconds 8 Error Flash with 16 Hz 2 1 2 Information LEDs 1 GSM Module active without data connection LED red static on 2 GSM Module active with internet connection LED red syncron to Status LED 3 GSM Module active with data connection LED red flas...

Page 8: ...of problems download and install the latest driver for VCP and D2XX from the FTDI homepage http www ftdichip com Drivers VCP htm Tip Open the device manager before connecting the Gateway USB cable After connecting the Gateway USB cable a new COM port appear Before connection After connection Gateway is on COM 15 Caution Once the Gateway is connected to a USB port it is in the configuration mode In...

Page 9: ...The Gateway will set the new values only by using the write button 3 1 1 2 Device identifier wildcards It is possible to put wildcards instead of the device identifier in some settings Identification no Manufacturer code Version code Device type Wildcard FFFFFFFF FF FF Example FFFFFFF EFE FF FF only Engelmann devices 12345678 FF 08 only heat cost allocator with serial number 12345678 3 1 1 3 Displ...

Page 10: ... configured can be selected here In our case the gateway must be selected omit Automatic device detection COM port selection After the gateway has been connected to the USB port the correct COM port can be selected in the Device Monitor First the COM port list should be updated and then the gateway COM port selected Settings menu The individual settings of the gateway can be selected here Settings...

Page 11: ...status and RSSI receive intensity indicate the current values from Gateway can t be set 3 3 1 2 GSM status Under GSM status you can check which provider GSM network the gateway is current using In addition it is possible to send a test file via the GSM network For this it is necessary that a FTP server was entered See Data Transfer and FTP Settings 3 3 1 3 Time settings A correct time setting is e...

Page 12: ...mail settings If E Mail functionality should be used the E Mail and SMTP settings must be entered In the E Mail settings field 4 reception email addresses can be entered The Gateway will send the collected device data to the mentioned addresses Please note that for every address a separate E Mail will be send note the energy budget Factory setting not set 3 3 2 3 SMTP settings If E Mail functional...

Page 13: ...l gmx net 587 on EHLO web de smtp web de 587 on EHLO Outlook Mail smtp mail outlook com 587 on EHLO It is necessary to set the ability to use external E Mail programs in web portal The list shows the actual E Mail service settings when the document was build In the meantime the settings could change and not correct anymore 3 3 2 4 Upload file format setting It is possible to choose between a CSV X...

Page 14: ...ES master keys can be stored An AES key is a hexadecimal number with 32 characters Read state Output of a meter identifier list with masked AES keys Delete The stored list is completely deleted Write Save the settings 3 3 3 3 AES individual key settings Individual AES Keys can be stored for individual meters For this it is necessary to fill all fields without wildcards Read state Output of a meter...

Page 15: ...P upload 60 minutes time gap to the next action E Mail dispatch 60 minutes time gap to the next action Time settings There are several ways to set the time intervals in the Device Monitor Shown in red Point in time This is the possibility to set the time at the beginning of the month or middle of the month or the end of the month You can also select all 3 Month start times at the same time Energy ...

Page 16: ...ee picture 3 3 4 2 FTP upload timings Possibility to set the time timeframe and interval when the gateway uploads the meter data to FTP server Factory setting see picture 3 3 4 3 Email dispatching timings Possibility to set the time timeframe and interval when the gateway sends the meter data to the SMTP server Factory setting disabled see picture 3 3 4 4 SMS reception timings Possibility to set t...

Page 17: ... code in for the current settings Calculation adjusted annual consumption maximum permissible annual consumption 100 The display is updated every time the Read button is pushed Furthermore every time Read or Write button of the previous timing settings are pushed the displayed value is updated Values 100 are set in the Gateway Values 100 are not accepted by the Gateway Energy budget 100 are only p...

Page 18: ...d Blacklist BL are used to restrict the found meters required by the customer Here the Blacklist limits the Whitelist Whitelist Only meter data are collected that corresponds to the Whitelist Blacklist All meter data that does not correspond to the black list are recorded 3 4 1 Devicelist Result list Shows the found or imported device identifier Filter list Shows the not wanted device identifier F...

Page 19: ...ader with the mouse Remark The device search function works only with the APN set scan whitelist Devices search based on Whitelist scan all Devices search without restriction refresh black whitelist The filter lists are loaded into the Device Monitor from the Gateway Filter list and sum display will be updated accordingly Filter Add selected The selected devices in result list will be added to the...

Page 20: ...tifiers detections with their affiliations are displayed here import devices from CSV Import a file with device identifiers into result list Existing entries are deleted export devices from CSV Export a file with all device identifiers from result list export whitelist to CSV Export all WL marked device identifier into a CSV file export blacklist to CSV Export all BL marked device identifier into ...

Page 21: ... the Engelmann support 3 4 3 Operations 3 4 3 1 Features The following control elements are available for the Features setting Reset Device restart Factory settings Reset factory setting Set time via NTP Time setting is set automatically with the GSM time Activate GSM module Activates the GSM module Deactivate GSM module Deactivates the GSM module Start FTP upload The collected meter data are uplo...

Page 22: ...oad a new configuration from a FTP server The uploaded downloaded configuration files are different and can t be vice versa No file name is required to upload the configuration because the file name is created by the Gateway With the Read all button all settings are read out at once 3 5 Information 3 5 1 Gateway Information 3 5 1 1 Energy state All information regarding the past use of the Gateway...

Page 23: ... FTP open failed FTP server connection Error TLT FTP type failed FTP type Binary Error TLT FTP CWD failed FTP Index Error TLT FTP put failed FTP file creation Error TLT server connection lost FTP Email connection lost Error TLT server data stream timeout FTP Email Upload interrupt Error TLT server log timeout FTP Email Server Timeout Error TLT FTP upload failed FTP Fehler all FTP Errors Error TLT ...

Reviews: