IMPORTANT!
READ AND FOLLOW
ALL
INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING
CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR DUE
TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH QUESTIONS.
13
OPERATING INSTRUCTIONS
CAUTION: DO NOT OPERATE WITH THE DOOR OPEN.
Do not burn trash (paper bags, etc.) in this unit.
This stove has an induced draft system and is designed to operate continuously, as frequent
shutdown is not required. The setting of the
“Heat Range”
touch pad will control the heat output
and the amount of fuel the unit will burn (see “Control Board” section).
NOTE
: This stove is using solid fuel and will not restart automatically unless a thermostat is
installed. See page 26 – Thermostat instructions.
*
NOTE: Blower Speed will automatically be adjusted to the desired Heat Range that you select.
START- UP PROCEDURES
SETTING THE STIRRER
Warning: Do not open the door on this unit if the Stirrer is still moving!
Bodily Injury can occur!
The stirrer must be “set” before each burn so that the 4-prong side of the stirrer is pointing
straight up (see diagram below). To rotate the Stirrer, press and hold the “AIR ON TEMP” (i.e. “Air
On”) button (on the bottom of the Control Panel); it will stop rotating when you release the button.
To turn Stirrer Off and On: The Stirrer may be turned Off by pushing the “Air On” button on the
bottom of the Control Panel, and then pressing both Down arrows on the “Blower Speed” and “Heat
Range” until you see a “0” in the Blower Speed window. The Stirrer may be turned back On by
pressing the “Air On” button on the bottom of the Control Panel, and then pressing both Up arrows
on the “Blower Speed” and “Heat Range” until you see a “1” in the Blower Speed window.
CAUTION: Never use gasoline, lantern fuel, kerosene, charcoal lighter fluid, diesel fuel or
any other flammable liquid to start the fire. Keep all combustible materials at a
safe distance from stove.
The Heat Range and Blower Speed will automatically be set to setting “5” (default setting during
start up) to ensure that proof of fire is detected. During the 20 minute start-up period the user can set
the controls to a desired heat setting and
after
the 20 minute start-up the unit will operate at that user
setting. When burning corn, start-up period is 30 minutes.
Stirrer – Illustration 2
This prong must be in the upright
position when restarting the stove
(the 4-prong side is in 12:00 position)