Page 1: ...INSTALLATION OPERATION MANUAL Manufactured By England s Stove Works Inc PO Box 206 Monroe VA 24574 Rev 12 2016 Wood Stove MODELS 13 NC 50 SNC13 50 TNC13 SAVE THESE INSTRUCTIONS ...

Page 2: ... 19 Fiber Board 19 Burner Tubes 20 Creosote 21 Ash Disposal 21 Questions Hints and Tips 22 Parts and Options Parts Options List 24 Exploded View 25 Legs Pedestal Installation 25 Warranty Sample Tag 26 Warranty Details 27 Warranty Registration Form 28 Important Information EPA and Safety Info 30 IMPORTANT NOTES CLEARANCES MAY ONLY BE REDUCED BY MEANS APPROVED BY THE REGULATORY AUTHORITY HAVING JURI...

Page 3: ... materials This stove must be installed in accordance with the Manufactured Home and Safety Standard HUD CFR 3280 Part 24 and must comply with local building and fire codes Failure to follow these instructions could result in property damage bodily injury or even death Keep children furniture fixtures and combustibles away from any heating appliance NOTE THIS STOVE IS MOBILE HOME AND DOUBLE WIDE A...

Page 4: ...information obtained on our web site and through our 800 number is always free of charge there will be a service charge incurred with any on site repairs or maintenance that we may arrange Wishing you years of efficient quality and comfy heating England s Stove Works Technical Support Department www HeatRedefined com 800 245 6489 This manual is available for free download on the manufacturer s web...

Page 5: ...ble liquids or other combustible materials too close to the unit 12 Contact your local fire authority for information on how to handle a chimney fire Have a clearly understood plan to handle a chimney fire In the event of a chimney fire turn air control to a closed position and CALL THE FIRE DEPARTMENT 13 DO NOT tamper with the combustion air control beyond normal adjustment 14 Once the required d...

Page 6: ...can result in permanent damage to the heater The recommended wood load is level with the top of the firebricks Overloading may prevent sufficient air entering the heater to properly fuel the fire Do not tamper with the combustion air control beyond the normal adjustment capacity Operate this heater only with the door closed ALWAYS PROVIDE A SOURCE OF FRESH AIR INTO THE ROOM WHERE THE UNIT IS INSTA...

Page 7: ...f eighteen inches 18 0 from a combustible wall and eighteen inches 18 0 from ceiling 3 Installation of a New Flue System Note Flue systems and flue pipe are not furnished with the unit Masonry Flue In the event that you plan to install or have a system installed there are several approaches that you can take In the middle and late seventies masonry flue systems became very popular and today this t...

Page 8: ...8 13 0 Min 13 0 Min 13 0 Min Single wall chimney connector 18 Min USA Follow all venting system manufacturer s installation requirements AND their required clearances ...

Page 9: ... 5 in Single Wall Chimney Connector 18 Min Min Alcove Width 64 0 in Min Alcove Height 84 0 in Max Alcove Depth 48 0 in CANADA Follow all venting system manufacturer s installation requirements AND their required clearances ...

Page 10: ...10 INSTALLATION APPLICATIONS Cont d Illustration 1b In Canada the installation must conform to CAN CSA B365 when passing through combustible construction ...

Page 11: ...be able to recommend a qualified contractor for this installation It is the customer s responsibility to ensure that his system is installed properly and is in good operating condition The manufacturer will not be responsible for an accident caused by a unit connected to a faulty flue system FLOOR AND WALL PROTECTION 1 Floor Protection You will not need any floor protection if your floor is constr...

Page 12: ...ternate is 4 brick with a C factor of 1 25 over 1 8 mineral board with a k factor of 0 29 Step a Use formula above to convert specification to R value R 1 k x T 1 0 84 x 75 0 893 Step b Calculate R of proposed system 4 brick of C 1 25 therefore R brick 1 C 1 1 25 0 80 1 8 mineral board of k 0 29 therefore Rmin bd 1 0 29 x 0 125 0 431 Total R Rbrick Rmineral board 0 8 0 431 1 231 Step c Compare pro...

Page 13: ...ear Heat Shield and fasten with the screws provided See Illustration 1 for clearances with and without side heat shields Rear Heat Shield Side Heat Shield Side Heat Shield Illustration 3 Side Heat Shield and Blower Installation Install AC 16 Optional Blower on these 4 mounting holes See Optional Blower Instructions on page 4 for instructions Illustration 4 BRICK LAYOUT 1 9 x 4 x 1 25 brick Qty 11 ...

Page 14: ...t has the factory packaging remove the body of the stove from the shroud that it is attached to referring to Illustration 7 later in this manual Those instructions detail how to exchange legs and pedestal but removal of the shroud is accomplished in the same manner 2 Select the proper location for the stove These appliances must not be installed any closer than the minimum clearance to combustible...

Page 15: ...nstall in accordance with 24 CFR Part 3280 HUD Outside Air Connection When installing this model in a mobile home or double wide it is necessary to supply the combustion air into the unit from outside the dwelling NOTE THIS STOVE IS MOBILE HOME AND DOUBLE WIDE APPROVED WITH OUTSIDE AIR HOOK UP FOR THE PEDESTAL MODEL ONLY NOT FOR LEG MODELS This can be done by running a thin gauge three inch 3 pipe...

Page 16: ...O CHIMNEY AND CHIMNEY CONNECTOR MANUFACTURER S INSTRUCTIONS WARNING INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER CONTACT YOUR LOCAL BUILDING AUTHORITY FOR APPROVED METHODS OF INSTALLATION 1 This appliance requires a masonry or pre manufactured chimney listed to UL103HT ULC S629 if Canada sized correctly 2 If a masonry chimney is used it is advisable to have your chimney inspected ...

Page 17: ...t effectively when air is allowed to circulate to all areas of the firebox A good way of achieving this is to rake a small 1 to 2 wide trough in the center of the coal bed from front to back prior to loading the fuel 7 Once fuel has been loaded close the door and fully open the air inlet control until the fire is well established approximately 20 minutes being careful not to over fire 8 Readjust t...

Page 18: ...ce deposits on the glass GASKET REPLACEMENT After extensive use the sealing material which provides glass and door seal may need to be replaced if it does not sustain its resilience Inspect the glass and door seal periodically to ensure proper seal If the gaskets become frayed or worn replace immediately Contact your dealer or Customer Service at 800 245 6489 for approved replacement parts The fol...

Page 19: ... SURE IT IS LYING FLAT ON TOP OF THE THREE STAINLESS STEEL TUBES AND PUSHED ALL THE WAY TO THE BACK OF THE UNIT WITH NO GAPS BETWEEN IT AND THE BACK WALL Call 800 245 6489 if questions MAINTENACE This unit is equipped with a ceramic Fiber Board ceiling baffle After extensive use the board should be removed and cleaned The following steps should be followed for cleaning or replacement 1 Ensure the ...

Page 20: ...20 Placement of Stainless Steel Burner Tubes for all 13 NCMH 50 SNC13MH and 50 TNC13MH stove models ...

Page 21: ...A small hot fire is preferable to a large smoldering one that can deposit creosote within the system 5 Establish a routine for fuel wood burner and firing technique Check daily for creosote build up until experience shows you how often you need to clean to be safe Keep in mind that the hotter the fire the less creosote is deposited and weekly cleanings may be necessary in milder weather although m...

Page 22: ...on of smoke is a good indication that the draft in the chimney has begun and good combustion is now possible Larger pieces of seasoned dry firewood can now be added when there is sufficient space in the firebox Adjust the air control setting to your desired setting NOTE The lower the air control setting the longer the burn time of the firewood 2 What type of wood is best to use as firewood Dry sea...

Page 23: ...s and door seals can all keep heat in but may also make a home too airtight If you are in doubt as to whether or not there is sufficient air in your home for your stove refrain from using those appliances known to consume air when possible or open a door or a window to allow some air to enter the home C Environmental Conditions High trees a low lying house location such as in a valley tall buildin...

Page 24: ...MIC FIBER BOARD AC SH BRASS DOOR SPRING HANDLE AC SHN NICKEL DOOR SPRING HANDLE AC SH4 BRASS AIR CONTROL SPRING HANDLE AC SH4N NICKEL AIR CONTROL SPRING HANDLE AC 03 BRASS ASH PAN KNOB AC 03BN NICKEL ASH PAN KNOB AC MBSP HI TEMPERATURE BLACK PAINT OPTIONS AC 16 ROOM AIR BLOWER AC NCSHSB SIDE HEAT SHIELD SYSTEM BLACK AC 108 BRASS ACCENT TRIM RING FOR DOOR C P AND L MODELS ONLY AC 108BN NICKEL ACCEN...

Page 25: ...o a slot and match the hole on the leg with the hole in the slot Attach the legs one at a time using the supplied bolts and nuts Tighten securely To install pedestal 1 Place spacers provided between the slots on the unit and the pedestal base one spacer will fit on each side of the pedestal Match the four holes in the pedestal 2 on each side with the holes in the spacers and slots on the unit 2 Us...

Page 26: ...anufacture Date and Serial Number in the blank spaces on this sample tag for future reference This sample tag also shows the safety info such as UL testing standard etc for your local officials or anyone else who may need reference information ...

Page 27: ...urs because of an accident improper handling improper installation improper operation abuse or unauthorized repair made or attempted to be made The manufacturer is not liable for indirect incidental or consequential damages in connection with the product including any cost or expense providing substitute equipment or service during periods of malfunction or nonuse All liability for any consequenti...

Page 28: ...Purchase Date _________________ Purchase Price ____________________ Serial Number _____________________ Mfg Date ______________________ How did you first hear about our product please check one ___ Word of Mouth ___ Burn Trailer Demonstration ___ Internet Other ____________________________________________________ Where did you receive information about our product please check one ___ Rec d info v...

Page 29: ...29 ...

Page 30: ...lt in poor stove performance property damage bodily injury or death Avoid make shift compromises when installing the venting system England s Stove Works is not responsible for any damage incurred due to a poor or unsafe installation Be certain that all aspects of the venting system are installed to the venting manufacturer s instructions particularly the required clearances to combustibles Also b...

Page 31: ...or Building a Fire will ensure a proper fire as well as helping minimize visible emissions More Fuel loading and re loading Practical Tips for Building a Fire See your owner s manual for information on loading and re loading your fuel as well as for fire starting procedures i e Building a Fire Top Down Fires The US EPA recognizes the effectiveness of the top down approach for starting fires A good...

Page 32: ...about 12 to 15 percent Most air dried material is usually closer to 20 percent moisture content when used To test your firewood simply push the pins into the wood and wait for a reading Remember don t just stick the meter into the ends of your firewood To get the most accurate reading split the wood and test the center The center of the log will contain the most moisture How Far Should I Drive Non...

Page 33: ...w these guidelines for safe operation Keep all flammable household items drapes furniture newspapers and books far away from the appliance Start fires only with newspaper dry kindling and all natural or organic fire starters Never start a fire with gasoline kerosene or charcoal starter Do not burn wet or green unseasoned logs Do not use logs made from wax and sawdust in your wood stove they are ma...

Page 34: ...alarms CAUTION This unit is meant to operate only with door closed Smoke spillage and an inefficient lazy burn will result from attempting to operate the stove with the door open Additionally using prohibited fuels can create an unsafe situation and can also generate excess carbon monoxide Carbon monoxide is an odorless colorless gas which can be deadly The use of a carbon monoxide detector is str...

Page 35: ...té HUD CFR 3280 Part 24 et doit obligatoirement respecter les codes locaux du bâtiment et de prévention des incendies Le non respect de ces instructions risque d entraîner des dommages aux biens des blessures corporelles ou même la mort Tenez les enfants les meubles les appareils et tous les produits combustibles à l écart des appareils de chauffage REMARQUE CE POÊLE EST AGRÉÉ POUR LES MAISONS MOB...

Page 36: ...rester prêts à chauffer tout particulièrement quand les tarifs de l huile et de l électricité continuent d augmenter N hésitez pas à consulter l importante section d aide sur notre site Web et à appeler notre service clientèle au 800 245 6489 si vous avez besoin d aide avec votre poêle Nous pouvons presque toujours vous aider à effectuer n importe quelle réparation régler un problème ou répondre a...

Page 37: ...ux combustibles trop près de l appareil 12 Prenez contact avec le service d incendie local pour tous renseignements sur la manière de traiter un feu de cheminée Ayez un plan clairement compris pour traiter un feu de cheminée En cas de feu de cheminée fermez la commande de tirage et APPELEZ LES POMPIERS 13 NE MANIPULEZ PAS la commande de tirage au delà des réglages normaux 14 Une fois le tirage req...

Page 38: ...e risquent de causer des dommages permanents à celui ci La charge de bois recommandée est au niveau du haut des briques réfractaires Une surcharge risque d empêcher suffisamment d air d entrer dans le poêle pour alimenter le feu correctement Ne manipulez pas le régulateur d air de combustion au delà des réglages normaux Ne faites fonctionner cet appareil de chauffage qu avec la porte fermée FOURNI...

Page 39: ... noire doit être en acier calibre 24 à treize pouces 18 d un mur de combustion et à dix huit pouces 18 0 d un plafond 3 Installation d un conduit de fumée neuf Remarque Ni conduits de fumée ni tuyaux ne sont fournis avec l appareil Conduit de fumée maçonné Au cas où vous prévoiriez d installer un circuit ou d en faire installer un vous avez plusieurs solutions Au milieu et à la fin des années soix...

Page 40: ...le Espaces pour combustibles Largeur alcove min 64 pouces Hauteur alcove min 84 pouces Profondeur alcove max 48 pouces 23 5 13 5 24 5 1108 mm x 1042 mm Suivez toutes les exigencies d installation du fabricant du système de ventilation et de leurs autorisations nécessaires 18 ...

Page 41: ...male de 6 po L ouverture doit obligatoirement être couvert et le manchon d emboîtement soutenu par un support en tôle d acier d épaisseur n 24 au minimum D Longueur de cheminée préfabriquée à isolation pleine homologuée ayant un diamètre intérieur 2 po plus grand que le raccord et ayant au moins 1 po de revêtement isolant pour servir de gaine à un raccord à paroi simple en tôle d acier d épaisseur...

Page 42: ...nstallé correctement les dégagements corrects sont réalisés Si vous ne pouvez pas installer ce type de conduite votre concessionnaire local pourra vous recommander un entrepreneur qualifié pour cette installation C est la responsabilité du consommateur de s assurer que le conduit est sûr et en bon état de fonctionnement Le fabricant ne saura être tenu pour responsable d un éventuel accident causé ...

Page 43: ... de la brique de 4 po ayant un facteur C de 1 25 sur une planche de type minéral de 1 8 po ayant un coefficient K de 0 29 Étape a Servez vous de la formule ci dessus pour convertir les spécifications en valeur R R 1 k x T 1 0 84 x 0 75 0 89393 Étape b Calculez le R du système proposé Brique de 4 po avec C 1 25 par conséquent le R de la brique 1 C 1 1 25 0 80 Planche de type minéral de 1 8 po avec ...

Page 44: ...s trous pré percés de l écran latéral avec les trous existants dans l écran thermique arrière et fixez les à l aide des vis fournies Voir l illustration 1 pour les dégagement avec et sans écrans thermiques latéraux Illustration 4 IMPLANTATION DES BRIQUES 1 Brique 9 x 4 x 1 25 po Qté 11 3 Brique 4 x 2 5 x 1 25 po Qté 1 5 Brique 4 x 4 5 x 1 25 po Qté 1 7 Brique 9 x 2 5 x 1 25 po Qté 2 2 Brique 9 x 4...

Page 45: ...séparez le corps du poêle du socle auquel il est fixé en vous reportant à l illustration 7 ci dessous Ces instructions donnent des explications pour le remplacement des pieds et du piédestal mais la dépose du socle s accomplit de la même manière 2 Sélectionnez le meilleur emplacement pour le poêle Il est interdit d installer ces appareils à une distance inférieure au dégagement minimum par rapport...

Page 46: ...eur Lors de l installation de ce modèle dans une maison mobile simple ou double il est nécessaire de fournir à l appareil de l air pour la combustion provenant de l extérieur de la maison REMARQUE CE POÊLE EST AGRÉÉ POUR LES MAISONS MOBILES SIMPLES ET DOUBLES AGRÉÉES AVEC RACCORDEMENT À L AIR EXTÉRIEUR UNIQUEMENT POUR LE MODÈLE AVEC PIÉDESTAL PAS POUR LES MODÈLES À PIEDS Ceci s effectue à l aide d...

Page 47: ...CCORD DE CHEMINÉE Avertissement Installez VENT AU dégagements specifies PAR LA VENT DU FABRICANT PRENEZ CONTACT AVEC L AUTORITÉ DE CONSTRUCTION LOCALE POUR LES MÉTHODES D INSTALLATION AGRÉÉES 1 Cet appareil nécessite une cheminée maçonnée ou préfabriquée enregistrée en fonction de UL UL103HT ULC S629 Canada de dimensions correctes 2 Si une cheminée est utilisée il est recommandé de faire inspecter...

Page 48: ... zones du foyer Un bon moyen d y parvenir est de faire un petit sillon 1 à 2 po de large au milieu du lit de charbon d avant en arrière avant de mettre du combustible 7 Une fois le combustible chargé fermez la porte et ouvrez à fond la commande d arrivée d air jusqu à ce que le feu soit bien établi environ 20 minutes en veillant à ne pas le laisser s emballer 8 Ajustez le réglage de la commande d ...

Page 49: ...ilisation prolongée il pourra être nécessaire de remplacer le matériau qui assure l étanchéité de la vitre et de la porte s il perd sa souplesse Inspectez périodiquement les joints de la vitre et de la porte pour assurer qu ils assurent bien l étanchéité Si les joints s effilochent ou sont usés remplacez les immédiatement Prenez contact avec votre concessionnaire ou le service clientèle au 800 245...

Page 50: ...Z VOUS QU IL EST À PLAT SUR LES TROIS TUBES EN INOX ET QU IL EST POUSSÉ À FOND À L ARRIÈRE DU POÊLE SANS ESPACE ENTRE LE PANNEAU ET LA PAROI ARRIÈRE Appelez le 800 245 6489 si vous avez des questions ENTRETIEN Cet appareil est équipé d un déflecteur de plafond en panneau de fibre de céramiques Après une utilisation extensive il faut déposer et nettoyer le panneau Suivez les étapes ci dessous pour ...

Page 51: ...17 Positionnement des tubes de brûlage en inox pour tous les modèles de poêles 13 NCMH 50 SNC13MH et 50 TNC13MH ...

Page 52: ... dans le circuit 5 Établissez une routine pour la technique d allumage de chargement du bois et de brûlage Vérifiez tous les jours l absence de créosote jusqu à ce que l expérience vous indique à quelle fréquence le ramonage est nécessaire pour rester en sécurité N oubliez pas que plus un feu est chaud moins il se dépose de créosote et qu il peut y avoir besoin de faire un nettoyage par semaine en...

Page 53: ...poêle La réduction de la fumée est un bon indicateur que le tirage a commencé dans la cheminée et qu une bonne combustion est désormais possible Vous pouvez maintenant ajouter de gros morceaux de bois sec quand il y a suffisamment de place pour eux dans le foyer Régler le régulateur d air à l ouverture désirée REMARQUE Moins le régulateur d air est ouvert plus longtemps le bois brûlera 2 Quel est ...

Page 54: ...ité d air dans le domicile est suffisante ou pas évitez d utiliser ces appareils connus pour consommer de l air dans la mesure du possible ou ouvrez une porte ou une fenêtre pour permettre à l air d entrer dans le domicile FOURNISSEZ TOUJOURS UN APPORT EN AIR FRAIS DANS LA PIÈCE OÙ L UNITÉ EST INSTALLÉE LE NON RESPECT DE CETTE DIRECTIVE PEUT PRIVER LES AUTRES APPAREILS DE COMBUSTION D AIR ET CRÉER...

Page 55: ...13BTR TUBE DE BRÛLEUR ARRIÈRE AC 13CFB MH PANNEAU EN FIBRES DE CÉRAMIQUE AC SH POIGNÉE À RESSORT DE PORTE LAITON AC SHN POIGNÉE À RESSORT DE PORTE NICKEL AC SH4 POIGNÉE À RESSORT LAITON DU RÉGULATEUR D AIR AC SH4N POIGNÉE À RESSORT NICKEL DU RÉGULATEUR D AIR AC 03 POIGNÉE DE BAC À CENDRES LAITON AC 03BN POIGNÉE DE BAC À CENDRES NICKEL AC MBSP PEINTURE NOIRE HAUTE TEMPÉRATURE OPTIONS AC 16 SOUFFLAN...

Page 56: ... Mettez un pied dans une fente et alignez le trou du pied avec le trou de la fente Fixez les pieds un à la fois à l aide des boulons et écrous fournis Bloquez solidement Pour installer un piédestal 1 Mettez les entretoises fournies entre les fentes du poêle et l embase du piédestal une entretoise passe de chaque côté du piédestal Alignez les quatre trous du piédestal 2 de chaque côté avec les trou...

Page 57: ...23 ...

Page 58: ...tention de mauvaise installation de fonctionnement incorrect ou de réparations ou de tentatives de réparation non autorisées Le fabricant n est pas responsable des dommages intérêts immatériels indirects ou accessoires liés au produit y compris les éventuels coûts ou dépenses de fourniture d un équipement ou service de remplacement pendant les périodes de dysfonctionnement ou de non utilisation To...

Page 59: ...ix d achat ________________________ Numéro de série _____________________ Date de fabrication ______________________ Comment avez vous entendu parler de notre produit veuillez cocher une réponse ___ Bouche à oreille ___ Démonstration de la remorque ___ Internet Autre ____________________________________________________ Où avez vous reçu des renseignements au sujet de notre produit veuillez cocher ...

Page 60: ......

Page 61: ... détail ci après Le non respect des détails mentionnés pourrait réduire son rendement et causer des dommages matériels des blessures ou la mort Évitez d avoir recours à des expédients lors de l installation du système de ventilation England s Stove Works n est pas responsable des dommages causés par une installation incorrecte ou non sécuritaire Assurez vous de bien suivre toutes les instructions ...

Page 62: ... 91 m 3 pi au dessus du point où son axe central traverse le toit ET la cheminée doit se terminer à 0 61 m 2 pi au dessus de toute partie du logement dans un rayon de 3 05 m 10 pi de la cheminée Fonctionnement et entretien Consultez les sections sur le fonctionnement mode d emploi et l entretien y compris le retrait et l élimination des cendres de votre guide d utilisation et suivez les directives...

Page 63: ... fendre se tordre ou autrement changer de forme en séchant la plupart des bois doivent être séchés avant d être utilisés Le séchage à l air est la méthode la plus fréquemment utilisée pour le bois enstéré Dans la plupart des régions des États Unis la teneur en humidité minimale qu il est possible d obtenir par un séchage à l air est d environ 12 à 15 La plupart des matériaux séchés à l air ont une...

Page 64: ...sécuritaires Une fois que votre appareil de chauffage au bois est correctement installé suivez ces directives pour assurer un fonctionnement sécuritaire Conservez tous les articles de maison inflammables draps meubles journaux et livres loin de l appareil Pour allumer un feu utilisez uniquement du papier journal du bois d allumage et un allume feu entièrement naturel ou biologique N utilisez jamai...

Page 65: ... détecteur de fumée directement au dessus de l appareil pourrait causer des alarmes intempestives MISE EN GARDE Cet appareil est conçu pour fonctionner uniquement lorsque la porte est fermée L utilisation du poêle avec la porte ouverte provoquerait un refoulement de fumée et une combustion lente et inefficace De plus l utilisation de combustibles interdits peut être dangereuse et produire un excès...