SPECIFICATIONS

 

 

Heating

 

Specifications

 

 

• 

Maximum

 

Burn

 

Time**

 

.............................................................................

            

Up

 

to

 

14

  

hours

 

• 

Approximate

 

Square

 

Footage

 

Heated***

 

...............................................

            

2,400

 

sq.

 

ft.

 

• 

Flue

 

Collar

 

.................................................................................................

                           

6.0

 

in.

 

round

 

 

 

Dimensions

 

(Inches)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions

 

are

 

approximate.

 

Be

 

sure

 

to

 

locate

 

your

 

stove

 

in

 

the

 

installation

 

area

 

before

 

installing

 

pipe,

 

etc.

 

 

EPA

 

and

 

Safety

 

Compliance

 

Specifications

 

 

  

EPA

 

Compliance

 

Status

  

…….................

 

Certified

 

to

 

comply

 

with

 

2020

 

particulate

 

emission

 

standards

 

using

 

cord

 

wood.

 

 

  

EPA

 

Test

 

Standard

 

………………………………….

 

ASTM

 

E3053

17,

 

EPA

 

Alt

 

125,

 

CSA

 

B415.1

10

 

 

Particulate

 

Emissions

 

............................................................................

       

1.8

  

grams/hr

 

 

      

CO

 

Emissions

  

……………………………………………………………………..………….

         

1.9

 

grams/min

 

 

      

Heat

 

Output

 

Range

 

…………………………………………….……………………..

  

17500

 

 

65900

 

Btu/hr

 

 

Efficiency*

 

...................................................................................................

         

72%

 

HHV

 

 

 

Certified

 

To

 

…………………………………………

  

UL

 

1482

2011(R2015)

 

and

 

ULC

S627

00(R2016)

 

 

**

 ‐ 

Maximum

 

burn

 

times

 

are

 

heavily

 

dependent

 

on

 

the

 

type

 

of

 

wood

 

burned

 

in

 

the

 

stove;

 

as

 

such,

 

these

 

numbers

 

may

 

vary.

 

***

 ‐ 

The

 

maximum

  

heating

 

capacity

 

of

 

this

 

unit

 

can

 

vary

 

greatly

 

based

 

on

 

climate,

 

construction

 

style,

 

insulation

 

and

 

a

 

myriad

 

of

 

other

 

factors.

  

Use

 

this

 

information

 

in

 

conjunction

 

with

 

a

 

BTU

 

loss

 

calculation

 

for

 

your

 

home

 

to

 

determine

 

if

 

this

 

unit

 

will

 

be

 

sufficient

 

for

 

your

 

needs.

 

 

TAMPER

 

WARNING:

 

“This

 

wood

 

heater

 

has

 

a

 

manufacturer

set

 

minimum

 

low

 

burn

 

rate

 

that

 

must

 

not

 

be

 

altered.

 

It

 

is

 

against

 

federal

 

regulations

 

to

 

alter

 

this

 

setting

 

or

 

otherwise

 

operate

 

this

 

wood

 

heater

 

in

 

a

 

manner

 

inconsistent

 

with

 

operating

 

instructions

 

in

 

this

 

manual.”

 

 

“This

 

wood

 

heater

 

needs

 

periodic

 

inspection

 

and

 

repair

 

for

 

proper

 

operation.

 

It

 

is

 

against

 

federal

 

regulations

 

to

 

operate

 

this

 

wood

 

heater

 

in

 

a

 

manner

 

inconsistent

 

with

 

operating

 

instructions

 

in

 

this

 

manual.”

34

 

1

/

4

 

35

 

3

/

4

 

27

 

3

/

8

 

23

 

3

/

4

 

36

in.

 

High

 

26

in.

 

Deep

 

27

in.

 

Wide

 

 

Summary of Contents for 15-W06

Page 1: ... the installation instructions outlined in this manual Contact your local building or fire officials about restrictions and installation inspection requirements including permits in your area PFS File Number 20 607 Rev 6 2020 THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER OPERATION CONSULT THE OWNER S MANUAL FOR FURTHER INFORMATION IT IS AGAINST FEDERAL REGULATIONS TO OPERATE THI...

Page 2: ...of Manufacture Serial Number This information can be found on the safety tag attached to the rear of the unit Have this information on hand if you phone the factory or your dealer regarding this product Keep children away CAUTION Supervise children in the same room as this appliance Alert children and adults to the hazards of high temperatures Do NOT operate with protective barriers open or remove...

Page 3: ...g 31 Illustrated Parts Detail Parts List 32 Brick Layout 33 Warranty Sample Tag 34 Warranty Details 35 Important Notice 36 Warranty registration Form 37 This manual is available for free download on the manufacturer s web site It is a copyrighted document and resale is strictly prohibited The manufacturer may update this manual occasionally and cannot be responsible for problems including injuries...

Page 4: ... our web site and call our Technical Support department at 800 245 6489 if you need any help with your unit We are nearly always able to help walk you through any repairs problems or questions you may have PLEASE NOTE While information obtained on our web site and through our 800 number is always free of charge there will be a service charge incurred with any on site repairs or maintenance that we...

Page 5: ...dent on the type of wood burned in the stove as such these numbers may vary The maximum heating capacity of this unit can vary greatly based on climate construction style insulation and a myriad of other factors Use this information in conjunction with a BTU loss calculation for your home to determine if this unit will be sufficient for your needs TAMPER WARNING This wood heater has a manufacturer...

Page 6: ... line Keeping the entire chimney system inside the heated envelope of the home will ensure a strong easy to initiate draft in the chimney Although exterior chimney systems often function properly they are more likely to suffer from cold down drafts at start up or provide weak draft to the unit Also consider the cross sectional area of the chimney although existing masonry chimneys can often be use...

Page 7: ...m in cm in cm in cm in cm Single Wall Chimney Connector Unprotected Surface with side shields 19 48 3 30 76 2 12 30 5 6 15 2 5 12 7 17 43 2 Double Wall Chimney Connector Unprotected Surface with side shields 19 48 3 30 76 2 12 30 5 6 15 2 5 12 7 17 43 2 Notes for this unit The product may differ slightly from the diagrams The clearances are the minimum for this unit and may need to be increased fo...

Page 8: ...nd national fire codes and if you re uncertain about how to safely install the stove we strongly recommend contacting a local NFI certified installer to perform the installation ALWAYS install vent pipe in strict adherence to the instructions and clearances included with your venting system DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE DO NOT install a flue pipe damper or an...

Page 9: ...tric or stovepipe damper with this unit Never use single wall or double chimney connector as a chimney system never pass either type of chimney connector through a combustible wall without carefully following the manufacturer s instructions and those listed in the following page on Wall Pass Throughs NEVER pass chimney connector through an attic floor closet or roof Only use 24 gauge MSG black sin...

Page 10: ...INSTALLATION Wall Pass Throughs In Canada the installation must conform to CAN CSA 8365 when passing through combustible construction Page 10 ...

Page 11: ...wall chimney connector joint check manufacturer s recommendations when double wall chimney connector is used Drill three holes in the flue collar of the unit and attach the chimney connector to the unit using sheet metal screws holes should be pre drilled in flue collar from factory Properly attach the prefabricated chimney system to the home in strict accordance with the prefabricated chimney sys...

Page 12: ...at each single wall chimney connector joint check manufacturer s recommendations when double wall chimney connector is used Drill three holes in the flue collar of the unit and attach the chimney connector to the unit using sheet metal screws holes should be pre drilled in flue collar from factory Properly attach the prefabricated chimney system to the home in strict accordance with the prefabrica...

Page 13: ...himney connector is used Drill three holes in the flue collar of the unit and attach the chimney connector to the unit using sheet metal screws holes should be pre drilled in flue collar from factory Avoid numerous elbows and excessive horizontal runs as both will lead to poor draft and increased creosote accumulation Horizontal runs of chimney connector must never exceed 4 0 ft and the overall le...

Page 14: ...al Inspect your fireplace to ensure it is in proper working order and free of any obstructions Prior to installation remove the existing damper or wire it to fasten it open Venting Your Stove Direct Connect When this unit is direct connected it will require six inch 6 diameter 24 gauge pipe from the stove through the damper opening NOTE The chimney connector must be attached to the appliance with ...

Page 15: ...Safety Standard Chimney Cap Spark Arrestor Class A Chimney System Roof Flashing and Storm Collar Joist Shield Firestop Mobile Home Approved Double Wall Chimney Connector Use silicone to create a vapor barrier where the chimney passes through to exterior HUD CFR 3280 Part 24 as well as any applicable local codes Outside Combustion Air The use of outside combustion air is mandatory when installing t...

Page 16: ...hearth rug is NOT an approved substitute for a proper hearth pad For the US The floor protector must extend at least 16 in from the front of the fuel opening 8 in from the sides of the door opening and 8 in from the rear of the unit For Canada The floor protector must extend at least 450 mm from the front of the fuel opening 200 mm from the sides of the door opening and 200 mm from the rear of the...

Page 17: ... left side of the stove above the door Once this temperature has been reached allow the fire to die out with the air control open The second and third break in fires should be a bit larger with some small dry splits added to the kindling load The temperature goal during these fires is about 350 F 450 F don t let the fire get hotter than that Continuous Operation Daily Operation after your Break In...

Page 18: ...eratures and that the secondary combustion system is functioning properly Additionally follow the guidelines below for acceptable blower speeds When using the optional room air convection blower Part No AC 16 or you can upgrade to the AC 30 the blower should be operated as follows depending on heat output level Burn Rate High Medium High Medium Medium Low Low Blower Speed AC 16 High High Low Low L...

Page 19: ...se of toxic fumes or render the heater ineffective and cause smoke Burning fuels other than cordwood particularly coal and charcoal can result in hazardous concentrations of carbon monoxide being emitted into the dwelling For these reasons NEVER burn coal or charcoal in this cordwood stove Installing a carbon monoxide detector and being aware of the symptoms of carbon monoxide poisoning can help r...

Page 20: ... a fire with gasoline kerosene or charcoal starter Do not burn wet or green unseasoned logs Do not use logs made from wax and sawdust in your wood stove they are made for open hearth fireplaces If you use manufactured logs choose from those made from 100 percent compressed saw dust Build hot fires For most appliances a smoldering fire is not a safe or efficient fire Keep the doors to your wood bur...

Page 21: ...ing page for instructions Thoroughly clean the chimney system and the chimney connector system Since the chimney connector is generally exposed to high exhaust temperatures inspect it carefully for leaks and weak spots replace any questionable pieces In the case of straight through the roof chimney system be certain to remove the ceramic fiber baffles before pushing the chimney sweeping brush down...

Page 22: ...skets should only be replaced with equivalent fiberglass gaskets purchased from England s Stove Works specifically for this unit Gaskets 1 Door This unit comes with a rope gasket around the door that should be replaced at least every year To replace the door gasket Part AC DGKHD the old gasket must first be removed entirely prior to adding the new adhesive you may have to scrape the old cement fro...

Page 23: ...be light and water is normally sufficient to remove the deposits If stubborn soot persists use a cleaner made specifically for this purpose Do not scrape the glass or use abrasive cleaners 3 Rinse the glass with clean water and dry the glass before resuming normal operation Glass Replacement 1 Remove the door from the stove and rest it face down on a firm work surface 2 Using a 5 16 wrench remove ...

Page 24: ...the top layer is oriented East West To replace a cracked or broken board first remove the front burner tube Then remove the board you need to replace Install the new board the boards should sit flush together side by side Replace the tube previously removed Dog box replacement See Brick Layout page 33 for dog box location in the firebox To replace the dog box first remove the ash pan Then remove t...

Page 25: ...iagram below for clarification on the room air blower installation See pages 17 and 18 for operation instructions This unit can use the AC 16 which comes standard with the unit or the AC 30 upgrade blower Both are installed using the four factory installed 5 16 screws The optional heat circulation blower on this stove requires periodic lubrication this lubrication should be performed no less than ...

Page 26: ...tem in which the chimney system pulls air through the stove This unit must be installed in accordance with the following detailed descriptions of venting techniques not installing the stove in accordance with the details listed here can result in poor stove performance property damage bodily injury or death Avoid make shift compromises when installing the venting system England s Stove Works is no...

Page 27: ...g system surfaces get HOT and can cause burns if touched Noncombustible shielding or guards may be required The 10 3 2 Rule The chimney system must terminate 3 0 ft above the point where it s centerline passes through the roof AND the chimney must terminate 2 0 ft above part of the dwelling within a 10 ft radius of the chimney Operation and Maintenance Please refer to the Operation Operating Instr...

Page 28: ...nformation Firewood is ready at 10 25 moisture content Newly cut logs can have a moisture content MC of 80 or more depending on species Since wood shrinks and can also split twist or otherwise change shape as it dries most wood is dried before being used Air drying or seasoning is the most common method used for cord wood In most parts of the United States the minimum moisture content that can be ...

Page 29: ...HEATER BURNING THESE MATERIALS MAY RESULT IN RELEASE OF TOXIC FUMES OR RENDER THE HEATER INEFFECTIVE AND CAUSE SMOKE Safe Wood burning Practices Once your wood burning appliance is properly installed follow these guidelines for safe operation Keep all flammable household items drapes furniture newspapers and books far away from the appliance Start fires only with newspaper dry kindling and all nat...

Page 30: ... the tubes in the correct order Front to Back Smoke Detectors England s Stove Works Inc highly recommends the use of smoke detectors in every room of the house However locating a smoke detector directly above this unit can result in nuisance alarms CAUTION This unit is meant to operate only with door closed Smoke spillage and an inefficient lazy burn will result from attempting to operate the stov...

Page 31: ...rating Stove at Low Burn Rate 8 Wood Loaded Too Close to Glass Coals build up in firebox 9 Operating Stove at High Burn Rates 7 1 Operate the stove at higher burn rates to allow the air wash system to keep the glass clean 8 1 Never load wood so that it is touching the ceramic glass viewing window 9 1 Reduce combustion air control and allow coals to burn down before reloading Fire burns out of cont...

Page 32: ...sket kit 3 4 flat AC GGK 1 Door gasket kit 3 4 high density AC DGKHD 1 Front burner tube AC W06FBT 1 Middle burner tube AC W02MBT 1 Rear burner tube AC W02RBT 1 Glass size 20 75 X 12 625 AC G51 1 Ceramic fiberboard AC W02CFB 4 Small spring handle Nickel AC SH4N 1 Large spring handle Nickel AC SHN 1 Blower back cover AC BBC30 1 Glass tabs AC W01GT 4 Hinge pins AC HP 2 Outside Air Kit AC OAK3 1 Air ...

Page 33: ...d after delivery DIAGRAM NUMBER BRICK SIZE PART NUMBER QUANTITY PER STOVE 1 9 X 4 X 1 25 AC SB 26 2 4 25 X 4 X 1 25 AC SB4 25 1 3 8 X 4 X 1 25 with Notch AC SB8x4 2 4 6 5 X 4 X 1 25 AC SB6 5 1 ASH DUMP PLUG CA 30ADP 1 1 2 3 4 3 Dog Box Steel 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Ash Plug ...

Page 34: ...cture Date and Serial Number in the blank spaces on this sample tag for future reference This sample tag also shows the safety info such as UL ULC testing standard etc for your local officials or anyone else who may need reference information ...

Page 35: ...st or expense or service during periods of malfunction or non use Do NOT use substitute materials or components to replace original equipment 4 All liability for any consequential damage for breach of any written or implied warranty is disclaimed and excluded 5 This warranty does not cover internal wear parts of the combustion system including the firebrick lining and gaskets 6 Warranty is void if...

Page 36: ...of these three easy ways to send your warranty information in Mailing Address England s Stove Works Inc Technical Support Department P O Box 206 Monroe Virginia 24574 Fax Number 434 929 4810 Twenty four hours a day Online Registration Visit our warranty registration website at www heatredefined com WARRANTY CARD LOCATED ON NEXT PAGE For parts warranty replacement procedures may be found at our par...

Page 37: ... State Zip Code Unit Information Refer to the sticker on the back of the manual or box to complete this section IX Model Number Purchase Date X Purchase Price XI Serial Number Mfg Date Purchase Questions How did you first hear about our product Please check one Word of Mouth Burn Trailer Demonstration Internet Other Where did you receive information about our product Via Telephone Dealer Name of d...

Reviews: