background image

SECTION lll:  FREESTANDING PLACEMENT AND INSTALLATION 

 

Once you have your flue system complete and have installed the floor and wall 

protection, you are ready to place your unit. The first problem you may encounter is 
getting the stove into your home; all of our products are well constructed, which makes 
them rather heavy. To lighten the stove you can remove the door and firebrick. Be sure 
to make a note of your unit’s brick placement before you remove your bricks. 

  

After the unit is in place the firebrick and door can be replaced. We recommend you 

use a handcart and never try handling one of our units without some help. As a rule, 
three or four adults can handle most of our products. 
 

A.  Chimney Connector 

 

The chimney connector must be 24 gauge steel pipe and six inches (6”) in 

diameter. Do not use aluminum or galvanized pipe for installation of this unit, as this 
type pipe will not be able to withstand the extreme temperatures a wood stove will 
generate. Do not use chimney connector pipe (single wall) as a chimney. You must 
connect your stove to a chimney comparable to those listed previously in this manual 
(See Section l). 

 
A chimney connector must be attached to the stove (and to each other) with the 

crimped end toward the stove. This allows any creosote to run back inside the pipe 
and not down the outside of the pipe. As a safety precaution, all joints should be 
sealed with high temperature silicone (AC-RTV3) and secured with three sheet metal 
screws, since the pipe could vibrate apart in the event of a creosote fire. 

 
For proper operation, the chimney connector should be as short as possible. 

Horizontal runs of chimney connector pipe should have an upward slope from the 
stove of one-quarter inch (1/4") per foot. Maintain eighteen inches (18”) of clearance 
between the chimney connector and the wall and ceiling unless a wall protection 
system is installed. When installing this stove in a mobile home or double wide you 
must use double wall or shielded pipe that will allow six inches (6”) clearance from a 
combustible. 

 

B.  Outside Air Connection 
 

When installing this model in a mobile home or double wide it is necessary to 

supply the combustion air into the unit from outside the dwelling. This can be done 
by running a thin gauge three inch (3”) pipe (flex or rigid) from the air inlet pipe 
located on the rear of the stove through the floor or wall. The outside end of this pipe 
should be covered in some manner to keep it clear of foreign matter. If you are 
installing this stove in a regular dwelling this connection is not necessary, but is 
recommended in air-tight homes. 

 

Summary of Contents for 18-MH

Page 1: ...s and all combustibles away from any heating appliance NOTE THIS STOVE IS MOBILE HOME AND DOUBLE WIDE APPROVED WITH OUTSIDE AIR HOOK UP DO NOT INSTALL IN A SLEEPING ROOM THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR WALL AND CEILING ROOF MUST BE MAINTAINED England s Stove Works highly recommends the use of smoke detectors and Carbon Monoxide detectors with any hearth product including this uni...

Page 2: ...g guide on our web site we have always tried to help our customers stay heat ready especially when oil and electricity prices continue to skyrocket Please look at our vast Help section on our web site and call our Customer Service department at 800 245 6489 if you need any help with your unit We are nearly always able to help walk you through any repairs problems or questions you may have PLEASE N...

Page 3: ... and inspect your flue system The sweep in most cases will be able to make any necessary repairs or at least recommend qualified people to do so It is not permissible to connect your new unit to a flue system that services another heating appliance B Flue Size Needed The proper flue size is determined by measuring the inside diameter of the flue collar on the unit This unit is equipped with a six ...

Page 4: ... involves connecting a metal pipe usually three inches 3 in diameter check your stove and the pipe can be flex or rigid from the air inlet pipe located on the bottom rear of the stove through your floor or wall The outside end of this pipe should be covered in some manner i e with a screen to keep it clear of foreign matter It is necessary to use this hookup if installing in a mobile home or doubl...

Page 5: ...oose has a recognized label such as U L B O C A or I C B O Any of these labels will ensure the flue system is constructed of the proper materials and meets the required safety standards Your Englander dealer will usually handle a top grade and approved flue system There are two very popular methods for installation of a pre manufactured flue system The most popular and least expensive is through t...

Page 6: ...r drywall In some areas local code may call for thirty six inches 36 clearance from a combustible therefore you should check to see which applies to your area If you need to place your unit closer it will require wall protection There are many wall board manufacturers and most require a one inch 1 air space between the wall and the board You can place your unit within twelve inches 12 of some boar...

Page 7: ...ch other with the crimped end toward the stove This allows any creosote to run back inside the pipe and not down the outside of the pipe As a safety precaution all joints should be sealed with high temperature silicone AC RTV3 and secured with three sheet metal screws since the pipe could vibrate apart in the event of a creosote fire For proper operation the chimney connector should be as short as...

Page 8: ... a wooden block or a rubber hammer If the J Channel is too loose and will not stay in place lay the piece on a flat surface and bend the short side in on each end and slightly in the middle Follow this procedure with each piece AC 106 P SH 106 P Brass Window Trim With the door closed take the spring clip that has a tee on one end and twist it into the groove on the rear side of the window trim You...

Page 9: ...etely 7 Close the door and allow the fire to burn thirty 30 minutes to one hour 8 Once you have established a hot bed of coals open the by pass damper add more wood fill the unit close the door and allow the wood to burn another thirty 30 minutes The final step is to close the by pass damper and place the slide damper at your desired setting Note Pulling the slide damper out or towards you increas...

Page 10: ...laced A chimney sweep can perform this inspection D Everyday Fueling Always open or pull out the by pass damper before opening the door of the stove The door should be cracked for five to ten minutes to allow the excess smoke to clear through your flue system Never open the door with the by pass damper closed This stove is designed to burn six to eight hours on one load of seasoned firewood Once y...

Page 11: ... CA 1710 is also held in place by four 4 3 8 brass nuts they take a 9 16 wrench The flame impingement plate must be removed before the combustor collar Once the second set of nuts is removed the collar will come out with the catalytic combustor seated in it Reverse this procedure to replace the collar and flame impingement plate 6 The catalytic combustor Part AC 6C3 is guaranteed by the manufactur...

Page 12: ...the high surface temperatures This spray paint can be ordered from your local dealer or from the factory SECTION VII CHIMNEY AND FLUE PIPE MAINTENANCE A Chimney System Many stove owners prefer to clean their own chimneys however we highly recommend a chimney sweep be contacted to do this job A professional sweep can clean and inspect your system and in some cases spot problems that you may overloo...

Page 13: ...too quickly as they pass up the chimney system When the flue gas cools too quickly it becomes heavy and will back up in the system this will often result in back puffing poor combustion and smoke odors in the house Burning the stove hotter will in some cases help this situation If you have any problem with back puffing or a poor drawing chimney system contact your local dealer or call the factory ...

Page 14: ... CA 1710 COMBUSTOR HOUSING CA 20 6 FLUE COLLAR IP 18PC FLAME IMPINGEMENT PLATE NOTE Accessory items and trim found in Section IV of this manual may also be ordered NOTE ALL PARTS CAN BE ORDERED FROM YOUR LOCAL DEALER FROM OUR FACTORY OR FROM OUR WEB SITE www englanderstoves com If you have any questions or problems contact our Customer Service Department at 1 800 245 6489 CUSTOMER SERVICE DEPARTME...

Page 15: ...t apply if damage occurs because of an accident improper handling improper operation improper installation abuse or unauthorized repair made or attempted to be made The manufacturer is not liable for indirect incidental or consequential damages in connection with the product including any cost or expense providing substitute equipment or service during periods of malfunction or nonuse All liabilit...

Page 16: ......

Page 17: ...e Date _________________ Purchase Price ____________________ Serial Number _____________________ Mfg Date ______________________ How did you first hear about our product please check one ___ Word of Mouth ___ Burn Trailer Demonstration ___ Internet Other ____________________________________________________ Where did you receive information about our product please check one ___ Rec d info via phon...

Reviews: