22
IMPORTANT!
READ
AND
FOLLOW
ALL
INSTALLATION
AND
MAINTENANCE
INSTRUCTIONS,
INCLUDING
CLEANING
THE
UNIT
AS
SPECIFIED,
AND
REPLACING
GASKETS
ANNUALLY,
AND
PARTS
AS
NEEDED.
ENGLAND’S
STOVE
WORKS
IS
NOT
RESPONSIBLE
FOR
ANY
DAMAGE
OR
INJURY
INCURRED
DUE
TO
NEGLECT,
OR
DUE
TO
UNSAFE
INSTALLATION
OR
USAGE
OF
THIS
PRODUCT.
CALL
TECHNICAL
SUPPORT
WITH
ANY
QUESTIONS.
ERROR
CODES
Error
messages
will
appear
and
scroll
across
the
display
of
the
control
board
if
the
unit
experiences
an
abnormal
condition.
When
these
errors
occur,
the
unit
will
proceed
to
a
shutdown
cycle,
during
which
time
the
control
board
will
not
permit
the
unit
to
be
restarted.
At
the
end
of
the
shutdown
cycle,
the
control
board
will
allow
the
code
to
be
cleared
and/or
the
unit
to
be
restarted.
In
the
event
an
error
message
appears,
however,
it
is
recommended
to
refer
to
the
troubleshooting
section
of
the
manual
(or
call
Tech.
Support
if
needed),
to
determine
and
correct
the
underlying
cause
of
the
message’s
appearance.
NOTE:
See
next
section
for
information
on
Troubleshooting
the
Error
Codes
Failed
to
start
If
the
unit
does
not
reach
its
minimum
operating
(or
“Proof
of
Fire”)
temperature
by
the
end
of
the
allotted
startup
time,
the
control
board
display
will
scroll
“FAILED
TO
START
SHUTTING
DOWN”,
at
which
time
the
unit
will
initiate
a
shutdown
cycle.
The
message
will
continue
to
scroll
during
this
time
until
the
unit
shuts
completely
off.
During
this
time,
the
stove
cannot
be
restarted;
if
the
“ON”
button
is
pressed
during
this
shutdown,
the
unit
will
scroll
“STOVE
MUST
SHUT
DOWN
TO
CLEAR
ERROR”
once,
before
reverting
to
the
previous
message.
Once
the
unit
has
shut
down
completely,
the
display
will
continue
to
scroll
“FAILED
TO
START”.
At
this
point
the
stove
can
be
restarted
in
its
normal
sequence
by
pressing
the
“ON”
button,
or
the
code
can
be
cleared
by
pressing
the
“OFF”
button.
Failed
on
Over
Temp
If,
at
any
time
while
the
unit
is
in
operation
and
the
firebox
sensor
reads
too
high
of
a
temperature,
the
unit
will
display
the
following
message:
“FAILED
ON
OVER
TEMP
SHUTTING
DOWN”.
The
unit
will
then
initiate
a
shutdown
cycle,
and
the
message
will
continue
to
scroll
during
this
time
until
the
unit
shuts
completely
off.
During
this
shutdown,
the
stove
cannot
be
restarted;
if
the
“ON”
button
is
pressed
during
shutdown
the
unit
will
scroll
“STOVE
MUST
SHUT
DOWN
TO
CLEAR
ERROR”
once,
before
reverting
to
the
previous
message.
Once
the
unit
has
shut
down
completely,
the
display
will
scroll
“FAILED
ON
OVER
TEMP”.
At
this
point
the
stove
can
be
restarted
in
its
normal
sequence
by
pressing
the
“ON”
button,
or
the
code
can
be
cleared
by
pressing
the
“OFF”
button.
Vacuum
Loss
This
unit
is
equipped
with
a
vacuum
actuated
“Door
Ajar”
safety
switch.
If
this
switch
is
sensed
as
being
open
for
a
period
of
30
continuous
seconds,
the
control
board
will
scroll