REPLACING
COMPONENTS
Igniter
Before
beginning
any
component
replacement,
be
certain
the
unit
is
unplugged
and
thoroughly
cooled
down.
Remove
the
rear
panel
of
the
unit,
using
a
5
/
16
”
wrench.
Locate
the
igniter
as
shown
in
the
diagram
below.
Disconnect
the
igniter
wiring
from
the
control
board
and
use
a
5
/
16
”
wrench
to
remove
the
two
igniter
retaining
screws
that
fasten
the
assembly
to
the
stove.
Remove
the
assembly
from
the
stove.
Loosen
the
Allen
set
screw
(
1
/
8
”
Allen
wrench)
from
the
igniter
tube
and
remove
the
old
igniter
cartridge.
Install
the
new
igniter
in
the
igniter
tube,
retighten
the
set
screw
and
reinstall
the
assembly
into
the
stove
(remember
to
reconnect
the
wiring).
Reinstall
the
rear
panel.
Summary of Contents for 25-CBPAH
Page 52: ......