meets
local
and
national
fire
codes,
and
if
you’re
uncertain
about
how
to
safely
install
the
stove,
we
strongly
recommend
contacting
a
local
NFI
certified
installer
to
perform
the
installation.
Venting
Guidelines:
ALWAYS
install
vent
pipe
in
strict
adherence
to
the
instructions
and
clearances
included
with
your
venting
system.
•
DO
NOT
CONNECT
THIS
UNIT
TO
A
CHIMNEY
FLUE
SERVING
ANOTHER
APPLIANCE.
•
DO
NOT
install
a
flue
pipe
damper
or
any
other
restrictive
device
in
the
exhaust
venting
system
of
this
unit.
•
USE
an
approved
wall
thimble
when
passing
through
a
wall
and
a
ceiling
support/fire
stop
when
passing
through
a
ceiling.
•
INSTALL
three
sheet
metal
screws
at
every
chimney
connector
joint.
•
AVOID
excessive
horizontal
runs
and
elbows,
as
both
will
reduce
the
draft
of
the
venting
system
and
will
result
in
poor
stove
performance.
•
INSPECT
your
venting
system
often,
to
be
certain
it
is
clear
of
creosote,
fly
‐
ash
and
other
restrictions.
•
CLEAN
the
venting
system
as
detailed
in
the
maintenance
section
of
this
manual.
•
ADHERE
to
the
10
‐
3
‐
2
rule
regarding
chimney
terminations.
•
INSTALL
single
wall
chimney
connector
with
the
male
end
down
to
prevent
creosote
leakage.
Follow
double
wall
chimney
connector
manufacturer’s
instructions
regarding
proper
pipe
installation.
WARNING
:
Venting
system
surfaces
get
HOT,
and
can
cause
burns
if
touched.
Noncombustible
shielding
or
guards
may
be
required
The
10
‐
3
‐
2
Rule:
The
chimney
system
must
terminate
3.0
ft
above
the
point
where
it’s
centerline
passes
through
the
roof
AND
the
chimney
must
terminate
2.0
ft.
above
part
of
the
dwelling
within
a
10
ft.
radius
of
the
chimney.