background image

Page | 8 

 

 

 

Venting

 

Introduction

 

INSTALLATION

 

Venting

 

Guidelines

 

 

This

 

wood

 

stove

 

operates

 

on

 

a

 

natural

 

draft

 

system,

 

in

 

which

 

the

 

chimney

 

system

 

pulls

 

air

 

through

 

the

 

stove.

 

This

 

unit

 

must

 

be

 

installed

 

in

 

accordance

 

with

 

the

 

following

 

detailed

 

descriptions

 

of

 

venting

 

techniques;

 

not

 

installing

 

the

 

stove

 

in

 

accordance

 

with

 

the

 

details

 

listed

 

here

 

can

 

result

 

in

 

poor

 

stove

 

performance,

 

property

 

damage,

 

bodily

 

injury

 

or

 

death.

 

Avoid

 

make

shift

 

compromises

 

when

 

installing

 

the

 

venting

 

system.

 

England’s

 

Stove

 

Works

 

is

 

not

 

responsible

 

for

 

any

 

damage

 

incurred

 

due

 

to

 

a

 

poor

 

or

 

unsafe

 

installation.

 

Be

 

certain

 

that

 

all

 

aspects

 

of

 

the

 

venting

 

system

 

are

 

installed

 

to

 

the

 

venting

 

manufacturer’s

 

instructions,

 

particularly

 

the

 

required

 

clearances

 

to

 

combustibles.

 

Also,

 

be

 

certain

 

to

 

use

 

an

 

attic

 

radiation

 

shield

 

to

 

prevent

 

insulation

 

from

 

contacting

 

a

 

chimney

 

which

 

passes

 

through

 

an

 

attic.

 

The

 

chimney

 

system

 

is

 

the

 

“engine”

 

which

 

drives

 

a

 

wood

 

stove,

 

so

 

it

 

is

 

imperative

 

for

 

proper

 

unit

 

function

 

that

 

the

 

venting

 

system

 

be

 

installed

 

exactly

 

as

 

described

 

in

 

the

 

following

 

section.

 

If

 

questions

 

arise

 

pertaining

 

to

 

the

 

safe

 

installation

 

of

 

the

 

stove,

 

our

 

Technical

 

Support

 

line

 

(800

245

6489)

 

is

 

available.

 

Contact

 

your

 

local

 

code

 

official

 

to

 

be

 

certain

 

your

 

installation

 

meets

 

local

 

and

 

national

 

fire

 

codes,

 

and

 

if

 

you’re

 

uncertain

 

about

 

how

 

to

 

safely

 

install

 

the

 

stove,

 

we

 

strongly

 

recommend

 

contacting

 

a

 

local

 

NFI

 

certified

 

installer

 

to

 

perform

 

the

 

installation.

 

 

• 

ALWAYS

 

install

 

vent

 

pipe

 

in

 

strict

 

adherence

 

to

 

the

 

instructions

 

and

 

clearances

 

included

 

with

 

your

 

venting

 

system.

 

• 

DO

 

NOT

 

connect

 

this

 

wood

 

stove

 

to

 

a

 

chimney

 

flue

 

which

 

also

 

serves

 

another

 

appliance.

 

• 

DO

 

NOT

 

install

 

a

 

flue

 

pipe

 

damper

 

or

 

any

 

other

 

restrictive

 

device

 

in

 

the

 

exhaust

 

venting

 

system

 

of

 

this

 

unit.

 

• 

USE

 

an

 

approved

 

wall

 

thimble

 

when

 

passing

 

through

 

a

 

wall

 

and

 

a

 

ceiling

 

support/fire

 

stop

 

when

 

passing

 

through

 

a

 

ceiling.

 

• 

INSTALL

 

three

 

sheet

 

metal

 

screws

 

at

 

every

 

chimney

 

connector

 

joint.

 

• 

AVOID

 

excessive

 

horizontal

 

runs

 

and

 

elbows,

 

as

 

both

 

will

 

reduce

 

the

 

draft

 

of

 

the

 

venting

 

system

 

and

 

will

 

result

 

in

 

poor

 

stove

 

performance.

 

• 

INSPECT

 

your

 

venting

 

system

 

often,

 

to

 

be

 

certain

 

it

 

is

 

clear

 

of

 

creosote,

 

fly

ash

 

and

 

other

 

restrictions.

 

• 

CLEAN

 

the

 

venting

 

system

 

as

 

detailed

 

in

 

the

 

maintenance

 

section

 

of

 

this

 

manual.

 

• 

ADHERE

 

to

 

the

 

10

3

2

 

rule

 

regarding

 

chimney

 

terminations.

 

• 

INSTALL

 

single

 

wall

 

chimney

 

connector

 

with

 

the

 

male

 

end

 

down

 

to

 

prevent

 

creosote

 

leakage.

 

Follow

 

double

 

wall

 

chimney

 

connector

 

manufacturer’s

 

instructions

 

regarding

 

proper

 

pipe

 

installation.

 

 

 

 

 

 

 

WARNING

:

 

Venting

 

system

 

surfaces

 

get

 

HOT,

 

and

 

can

 

cause

 

burns

 

if

 

touched.

 

Noncombustible

 

shielding

 

or

 

guards

 

may

 

be

 

required.

 

Summary of Contents for THE MADISON 15-SSW01

Page 1: ...ance Keep children furniture fixtures and all combustibles away from any heating appliance SAVE THESE INSTRUCTIONS SAFETY NOTICE Failure to follow these instructions can result in property damage bodily injury or even death For your safety and protection follow the installation instructions outlined in this manual Contact your local building or fire officials about restrictions and installation in...

Page 2: ...Purchase Date of Manufacture Serial Number This information can be found on the safety tag attached to the rear of the unit Have this information on hand if you phone the factory or your dealer regarding this product Keep children away CAUTION Supervise children in the same room as this appliance Alert children and adults to the hazards of high temperatures Do NOT operate with protective barriers ...

Page 3: ...tenance Stove Maintenance 20 Inspecting Gaskets 21 Finish 21 Replacing Components Glass 22 Burner Tubes 23 Ceramic Fiberboards 23 Door Hinges 23 Heat Shield Back Panel 23 Other Components 24 Optional Accessories AC 16 AC 30 Blower 24 Side Heat Shield 24 Troubleshooting Guide Troubleshooting 25 Illustrated Parts Detail Parts List 26 Exploded Parts Diagram 27 Brick Layout 28 Warranty Sample Tag 29 W...

Page 4: ...er while remaining simple our stoves are designed to perform extremely efficiently helping deliver more heat from less fuel Please look at our vast Help section on our website and call our Technical Support Department at 800 245 6489 if you need any help with your unit We are nearly always able to walk you through any installation issues repairs problems or other questions that you may have Wishin...

Page 5: ...tified Particulate Emissions 2 49 grams hr Efficiency 72 HHV 78 LHV Tested To UL 1482 ULC S627 00 Maximum burn times are heavily dependent on the type of wood burned in the stove as such these numbers may vary The maximum heating capacity of this unit can vary greatly based on climate construction style insulation and a myriad of other factors Use this information in conjunction with a BTU loss ca...

Page 6: ...eeping the entire chimney system inside the heated envelope of the home will ensure a strong easy to initiate draft in the chimney Although exterior chimney systems often function properly they are more likely to suffer from cold down drafts at start up or provide weak draft to the unit Also consider the cross sectional area of the chimney although existing masonry chimneys can often be used a lar...

Page 7: ... C D E F in mm in mm in mm in mm in mm in mm Single Wall Chimney Connector Unprotected Surface 21 5 546 1 29 736 6 12 304 8 7 5 190 5 9 5 241 3 19 482 6 Double Wall Chimney Connector Unprotected Surface N A N A N A N A N A N A Single Wall Chimney Connector Unprotected Surface with side shields 17 5 445 5 25 635 12 304 8 7 5 190 5 5 5 139 7 15 381 Double Wall Chimney Connector Unprotected Surface w...

Page 8: ...ial to be certain your installation meets local and national fire codes and if you re uncertain about how to safely install the stove we strongly recommend contacting a local NFI certified installer to perform the installation ALWAYS install vent pipe in strict adherence to the instructions and clearances included with your venting system DO NOT connect this wood stove to a chimney flue which also...

Page 9: ...tric or stovepipe damper with this unit Never use single wall or double chimney connector as a chimney system never pass either type of chimney connector through a combustible wall without carefully following the manufacturer s instructions and those listed in the following page on Wall Pass Throughs NEVER pass chimney connector through an attic floor closet or roof Only use 24 gauge MSG black sin...

Page 10: ...INSTALLATION Wall Pass Throughs In Canada the installation must conform to CAN CSA 8365 when passing through combustible construction Page 10 ...

Page 11: ...wall chimney connector joint check manufacturer s recommendations when double wall chimney connector is used Drill three holes in the flue collar of the unit and attach the chimney connector to the unit using sheet metal screws holes should be pre drilled in flue collar from factory Properly attach the prefabricated chimney system to the home in strict accordance with the prefabricated chimney sys...

Page 12: ...at each single wall chimney connector joint check manufacturer s recommendations when double wall chimney connector is used Drill three holes in the flue collar of the unit and attach the chimney connector to the unit using sheet metal screws holes should be pre drilled in flue collar from factory Properly attach the prefabricated chimney system to the home in strict accordance with the prefabrica...

Page 13: ...himney connector is used Drill three holes in the flue collar of the unit and attach the chimney connector to the unit using sheet metal screws holes should be pre drilled in flue collar from factory Avoid numerous elbows and excessive horizontal runs as both will lead to poor draft and increased creosote accumulation Horizontal runs of chimney connector must never exceed 4 0 ft and the overall le...

Page 14: ...t in a zero 0 clearance fireplace The manufacturer will not be held responsible for an accident resulting from this stove being installed on a hearth constructed of a combustible material Inspect your fireplace to ensure it is in proper working order and free of any obstructions Prior to installation remove the existing damper or wire it to fasten it open Venting Your Stove Direct Connect When thi...

Page 15: ...rk Arrestor Class A Chimney System Roof Flashing and Storm Collar Joist Shield Firestop Mobile Home Approved Double Wall Chimney Connector Use silicone to create a vapor barrier where the chimney passes through to exterior HUD CFR 3280 Part 24 as well as any applicable local codes Outside Combustion Air The use of outside combustion air is mandatory when installing this wood stove in a mobile or m...

Page 16: ...r protector only serves to keep ashes and sparks from landing on combustible flooring near the unit A hearth rug is NOT an approved substitute for a proper hearth pad No R Value is necessary For the US The floor protector must extend at least 16 in from the front of the fuel opening 8 in from the sides of the door opening and 8 in from the rear of the unit For Canada The floor protector must exten...

Page 17: ... is ready for continuous operation When burning the stove continuously do not allow ash and coals to accumulate higher than the air hole in the dog box Excessive coaling is often a result of burning wood at too high a burn rate and the coal bed should be allowed to burn down before reloading the stove with fresh wood Combustion air is delivered to the stove at two locations The majority of the pri...

Page 18: ...eration temperatures and that the secondary combustion system is functioning properly Additionally follow the guidelines below for acceptable blower speeds When using the optional room air convection blower Part No AC 16 or you can upgrade to the AC 30 the blower should be operated as follows depending on heat output level Burn Rate High Medium High Medium Medium Low Low Blower Speed AC 16 High Hi...

Page 19: ...ng this unit with the loading door latched loosely or open will allow excessive combustion air to reach the fire and will result in dangerously high unit temperatures High unit temperatures can damage the unit void the warranty or ignite creosote deposited in the chimney system by previous slow burning fires The natural draft that pulls air through this unit and allows the fire to burn uses the in...

Page 20: ...ns Thoroughly clean the chimney system and the chimney connector system Since the chimney connector is generally exposed to high exhaust temperatures inspect it carefully for leaks and weak spots replace any questionable pieces In the case of straight through the roof chimney system be certain to remove the ceramic fiber baffles before pushing the chimney sweeping brush down into the firebox Force...

Page 21: ...skets should only be replaced with equivalent fiberglass gaskets purchased from England s Stove Works specifically for this unit Gaskets 1 Door This unit comes with a rope gasket around the door that should be replaced at least every year To replace the door gasket Part AC DGKHD the old gasket must first be removed entirely prior to adding the new adhesive you may have to scrape the old cement fro...

Page 22: ...y be light and water is normally sufficient to remove the deposits If stubborn soot persists use a cleaner made specifically for this purpose Do not scrape the glass or use abrasive cleaners 3 Rinse the glass with clean water and dry the glass before resuming normal operation Glass Replacement 1 Remove the door from the stove and rest it face down on a firm work surface 2 Using a 5 16 wrench remov...

Page 23: ...e hinges on this unit were designed to be adjustable The plates are secured using a bolt and nut To adjust the hinge plates in or out first remove the door then use a socket and open ended wrench one on the nut and one on the bolt head and loosen the bolt nut Slide the plate in out as desired and then use the socket and wrench to tighten the bolt nut Use care when adjusting hinges If enough room i...

Page 24: ...ttest regions of the stove and transfer it into the home The mounting screws for the blower are installed into the rear convection channel at the factory mounting the blower only requires a 5 16 open end or socket wrench to remove these screws and install the blower When routing the power cord take care to keep away from hot areas of the unit and remember that this blower is for use only with the ...

Page 25: ...rating Stove at Low Burn Rate 8 Wood Loaded Too Close to Glass Coals build up in firebox 9 Operating Stove at High Burn Rates 7 1 Operate the stove at higher burn rates to allow the air wash system to keep the glass clean 8 1 Never load wood so that it is touching the ceramic glass viewing window 9 1 Reduce combustion air control and allow coals to burn down before reloading Fire burns out of cont...

Page 26: ...S 2 Not shown Large Upgrade Blower optional AC 30 1 Not shown Small standard blower AC 16 1 12 Glass gasket kit 3 4 flat AC GGK 1 16 Door gasket kit 3 4 high density AC DGKHD 1 3 Front burner tube AC W01FBT 1 17 Middle burner tube AC W01MBT 1 4 Rear burner tube AC W01RBT 1 13 Glass size 12 75 X 16 75 AC G50 1 2 Ceramic fiberboard AC W01CFB 2 Not shown Small spring handle Nickel Brass AC SH4N AC SH...

Page 27: ...Page 27 ILLUSTRATED PARTS DIAGRAM 16 ...

Page 28: ...the sides and rear will need to be installed after delivery DIAGRAM NUMBER BRICK SIZE PART NUMBER QUANTITY PER STOVE 1 9 X 4 X 1 25 AC SB 24 2 4 5 X 4 X 1 25 AC SB4 5 1 3 9 X 1 25 X 1 25 AC SB9X1 25 2 4 7 75 X 4 X 1 25 AC SB7 75 2 5 ASH DUMP PLUG CA 30ADP 1 ...

Page 29: ...cture Date and Serial Number in the blank spaces on this sample tag for future reference This sample tag also shows the safety info such as UL ULC testing standard etc for your local officials or anyone else who may need reference information ...

Page 30: ...ith the product including any cost or expense providing substitute equipment or service during periods of malfunction or non use 4 All liability for any consequential damage for breach of any written or implied warranty is disclaimed and excluded 5 This warranty does not cover internal wear parts of the combustion system including the vermiculite firebox lining and gaskets Some states do not allow...

Page 31: ...urchase Use any of these three easy ways to send your warranty information in Mailing Address England s Stove Works Inc Technical Support Department P O Box 206 Monroe Virginia 24574 Fax Number 434 929 4810 Twenty four hours a day Online Registration Visit our warranty registration website at http www englanderstoves com warranty warranty html WARRANTY CARD LOCATED ON NEXT PAGE ...

Page 32: ......

Page 33: ...City State Zip Code Unit Information Refer to the sticker on the back of the manual or box to complete this section IX Model Number Purchase Date X Purchase Price XI Serial Number Mfg Date Purchase Questions How did you first hear about our product Please check one Word of Mouth Burn Trailer Demonstration Internet Other Where did you receive information about our product Via Telephone Dealer Name ...

Page 34: ......

Page 35: ...s matières combustibles CONSERVEZ CES INSTRUCTIONS AVIS DE SÉCURITÉ Le non respect de ces instructions peut causer des dommages matériels des blessures ou même la mort Pour votre sécurité et votre protection suivez les instructions pour l installation décrites dans ce guide Communiquez avec les autorités locales en matière de construction ou le service d incendie afin de connaître les restrictions...

Page 36: ...enseignements sont inscrits sur l étiquette de sécurité fixée à l arrière de l appareil Ayez ces renseignements à portée de la main si vous appelez le fabricant ou votre détaillant au sujet de ce produit Gardez les enfants à l écart Surveillez les enfants qui se trouvent dans la même pièce que cet appareil Prévenez les enfants et les adultes des risques que représentent les températures élevées N ...

Page 37: ...des joints d étanchéité 22 Fini 22 Remplacement des composants Vitre 23 Tubes de brûleur 24 Panneaux en fibres de céramique 24 Charnières de porte 24 Écran thermique et panneau arrière 24 Autres composants 25 Accessoires en option Ventilateur AC 16 ou AC 30 25 Écran thermique latéral 25 Guide de dépannage Dépannage 26 Illustration détaillée des pièces Liste des pièces 27 Vue éclatée des pièces 28 ...

Page 38: ...nt de conception simple nos poêles ont un rendement extrêmement efficace qui permet de produire plus de chaleur avec moins de combustible Si vous avez besoin d aide au sujet de votre appareil veuillez consulter la vaste section d aide de notre site Web ou appeler notre service de soutien technique au 1 800 245 6489 Nous sommes presque toujours en mesure de vous guider que ce soit pour l installati...

Page 39: ...rticules 2 49 g h Efficacité 72 PCS PCI de 78 Testé selon les normes UL 1482 ULC S627 00 La durée maximale de combustion dépend fortement du type de bois brûlé dans le poêle ces valeurs peuvent donc varier La capacité maximale de chauffage de cet appareil peut varier considérablement selon le climat le type de construction l isolation et de nombreux autres facteurs Combinez les renseignements expo...

Page 40: ...era un tirage fort et facile à amorcer dans la cheminée Bien que les systèmes de cheminée extérieurs fonctionnent souvent de façon adéquate ils subissent plus souvent le contre tirage d air froid à l allumage ou sont fréquemment la cause d un tirage faible de l appareil Tenez compte également de la section transversale de la cheminée Même si les cheminées en maçonnerie existantes peuvent souvent ê...

Page 41: ...in A B C D E F mm po mm po mm po mm po mm po mm po Raccord de cheminée à paroi simple sur une surface non protégée 546 1 21 5 736 6 29 304 8 12 190 5 7 5 241 3 9 5 482 6 19 Raccord de cheminée à paroi double sur une surface non protégée S O S O S O S O S O S O Raccord de cheminée à paroi simple sur une surface non protégée avec écrans latéraux 445 5 17 5 635 25 304 8 12 190 5 7 5 139 7 5 5 381 15 ...

Page 42: ...s n êtes pas certain de pouvoir installer le poêle de façon sécuritaire nous vous suggérons fortement de faire appel à un installateur local certifié par le NFI National Fireplace Institute des États Unis Installez TOUJOURS le tuyau de ventilation en respectant rigoureusement les instructions et les indications sur les dégagements qui accompagnent le système de ventilation Ne raccordez PAS le poêl...

Page 43: ... de registre de tirage sur cet appareil N utilisez jamais de raccord de cheminée à paroi simple ou double comme système de cheminée Ne faites jamais passer un raccord de cheminée dans un mur combustible sans respecter à la lettre les instructions du fabricant et celles indiquées à la page suivante concernant les traversées de mur Ne faites JAMAIS passer un raccord de cheminée à travers un grenier ...

Page 44: ...INSTALLATION Traversées de mur Au Canada l installation doit respecter la norme CAN CSA 8365 en cas de traversée de matériaux de construction combustibles Page 10 ...

Page 45: ...n raccord de cheminée à paroi double Percez trois trous dans la buse de l appareil et fixez le raccord de cheminée à l appareil au moyen de vis à tôle les trous devraient généralement être prépercés dans la buse à l usine Fixez correctement le système de cheminée préfabriqué à la maison en respectant précisément les instructions du fabricant du système de cheminée préfabriqué Évitez de trop nombre...

Page 46: ...e raccord de cheminée à paroi simple vérifiez les recommandations du fabricant lors de l utilisation d un raccord de cheminée à paroi double Percez trois trous dans la buse de l appareil et fixez le raccord de cheminée à l appareil au moyen de vis à tôle les trous devraient généralement être prépercés dans la buse à l usine Fixez correctement le système de cheminée préfabriqué à la maison en respe...

Page 47: ...reil et rendre l installation sécuritaire Utilisez un adaptateur de conception adéquate pour relier le raccord de cheminée à paroi simple ou double au manchon d emboîtement en maçonnerie Avant d utiliser l appareil faites inspecter la cheminée en maçonnerie existante afin de vous assurer que son utilisation est sécuritaire et que les distances minimales avec les matériaux combustibles sont respect...

Page 48: ...ns un foyer dont le dégagement est nul 0 Le fabricant ne sera pas tenu responsable d un accident causé par l installation de ce poêle sur un âtre fabriqué avec un matériau combustible Inspectez votre foyer pour vous assurer qu il est en bon état de fonctionnement et qu il est exempt d obstructions Avant l installation retirez le registre existant ou fixez le à l aide d un câble pour le maintenir o...

Page 49: ...le Le poêle à bois doit être raccordé au système de cheminée à l aide d un raccord de cheminée à paroi double homologué UL pour l utilisation dans une maison mobile ou préfabriquée Observez attentivement toutes les indications relatives au dégagement mentionnées à la section appropriée du présent guide ET respectez les exigences du fabricant du système de ventilation concernant les distances minim...

Page 50: ...ation de votre poêle vous pouvez utiliser d autres matériaux à condition d observer les règles suivantes o Le tuyau utilisé pour le raccordement d air extérieur doit être en métal et avoir une épaisseur minimale de 0 53 mm acier doux de calibre 25 et un diamètre intérieur d environ 7 cm o Conservez la longueur de tuyau courte et utilisez une fixation sur chaque joint de tuyau o Un écran ou un autr...

Page 51: ... les étincelles de tomber sur le plancher combustible près de l appareil Un tapis pour âtre n est PAS approuvé pour remplacer un protecteur d âtre approprié Aucune valeur d isolation thermique R n est nécessaire Pour les États Unis Le protecteur de plancher doit dépasser d au moins 40 64 cm à l avant de l ouverture pour le combustible de 20 32 cm sur les côtés de l ouverture de porte et de 20 32 c...

Page 52: ...ises s accumuler plus haut que le trou d air dans le boîtier de crampon Une quantité excessive de braises signifie souvent qu une trop grande quantité de bois brûle à un taux de combustion trop élevé et vous devriez laisser le lit de braises brûler avant d ajouter une nouvelle charge de bois au poêle L air comburant entre dans le poêle par deux endroits La majorité de l air comburant primaire entr...

Page 53: ...vez également les directives ci dessous pour connaître les vitesses appropriées du ventilateur Lorsque vous utilisez le ventilateur de convection de l air en option n de pièce AC 16 ou la nouvelle version AC 30 celui ci doit fonctionner comme suit selon le degré de chaleur Taux de combustion Élevé Moyennement élevé Moyen Moyennement bas Bas Vitesse du ventilateur AC 16 Élevée Élevée Basse Basse Ba...

Page 54: ...ment est fermée et bien verrouillée Le fonctionnement de cet appareil pendant que la porte de chargement est ouverte ou mal verrouillée causera l acheminement vers le feu d une quantité excessive d air comburant ce qui fera augmenter dangereusement la température de l appareil Une température élevée peut endommager l appareil ou enflammer la créosote accumulée dans le système de cheminée par les f...

Page 55: ...instructions Nettoyez à fond le système de cheminée et le système de raccord de cheminée Étant donné que le raccord de cheminée est généralement soumis à des températures d évacuation élevées vérifiez la présence de fuites et de points faibles puis remplacez les pièces dont l état est douteux Dans le cas d un système de cheminée complètement droit jusqu au toit assurez vous de retirer les déflecte...

Page 56: ...ialement conçus pour cet appareil par England s Stove Works Joints d étanchéité 1 Porte Cet appareil est muni d un joint d étanchéité cordé de 19 05 mm autour de la porte qui doit être remplacé au moins tous les ans Pour remplacer le joint d étanchéité de la porte n de pièce AC DGKNC retirez d abord le vieux joint en entier Avant d ajouter le nouvel adhésif vous devrez peut être gratter la vieille...

Page 57: ...ôts sur la vitre et ils peuvent habituellement être nettoyés avec de l eau Si de la suie tenace persiste utilisez un nettoyant spécialement conçu pour l enlever Vous ne devez pas gratter la vitre ni la nettoyer avec un produit abrasif 3 Rincez la vitre avec de l eau propre et séchez la avant de faire fonctionner le poêle à nouveau Remplacement de la vitre 1 Retirez la porte du poêle et placez la s...

Page 58: ...vers l intérieur ou vers l extérieur retirez d abord la porte puis desserrez le boulon et l écrou à l aide d une douille de 1 2 po et d une clé à fourches de 1 2 po une sur l écrou et une sur la tête de boulon Faites coulisser la plaque vers l intérieur ou vers l extérieur puis serrez le boulon et l écrou à l aide de la douille et de la clé Soyez vigilant lors du réglage des charnières Si vous ne ...

Page 59: ...sférer dans la maison Les vis de montage du ventilateur sont installées dans le profilé de convection arrière à l usine Le montage du ventilateur n exige qu une douille ou une clé à fourches de 5 16 po pour retirer ces vis et installer le ventilateur Lors de l acheminement du cordon d alimentation prenez soin de le garder à l écart des zones chaudes de l appareil et n oubliez pas que ce ventilateu...

Page 60: ... de la vitre Accumulation de braises dans 9 Utilisation du poêle la chambre de combustion à un taux de combustion élevé 7 1 Faites fonctionner le poêle à un taux de combustion plus élevé afin de permettre au système autonettoyant de conserver la vitre propre 8 1 Ne chargez jamais le bois de sorte qu il touche à la fenêtre en verre vitrocéramique 9 1 Réduisez l admission d air comburant et permette...

Page 61: ... option AC 30 1 Non illustré Petit ventilateur de série AC 16 1 12 Trousse de joint d étanchéité de vitre plat de 19 05 mm AC GGK 1 16 Trousse de joint d étanchéité de porte haute densité de 19 05 mm AC DGKHD 1 3 Tube de brûleur avant AC W01FBT 1 17 Tube de brûleur central AC W01MBT 1 4 Tube de brûleur arrière AC W01RBT 1 13 Dimensions de la vitre de AC G50 1 2 Panneau en fibres de céramique AC W0...

Page 62: ...Page 28 SCHÉMA DES PIÈCES 16 ...

Page 63: ...e installés après l accouchement NUMÉRO DE SCHÉMA DIMENSIONS DES BRIQUES NUMÉRO DE PIÈCE QUANTITÉ PAR POÊLE 1 22 86 cm x 10 16 cm x 3 18 cm AC SB 24 2 11 43 cm x 10 16 cm x 3 18 cm AC SB4 5 1 3 22 86 cm x 3 18 cm x 3 18 cm AC SB9X1 25 2 3 19 69 cm x 10 16 cm x 3 18 cm AC SB7 75 2 5 Trappe a cendres CA 30ADP 1 ...

Page 64: ...areil dans les espaces prévus à cet effet sur cette étiquette pour référence ultérieure Cette étiquette comprend également des renseignements de sécurité comme la norme d essai UL ULC au Canada à l intention de vos représentants locaux ou de toute autre personne qui peut en avoir besoin ...

Page 65: ...aration pendant les périodes de mauvais fonctionnement ou de non utilisation du produit 4 Le fabricant déclinera toute responsabilité pour les dommages consécutifs en cas de violation de toute garantie écrite ou implicite 5 Cette garantie ne couvre pas l usure des pièces internes du système de combustion y compris le revêtement en vermiculite de la chambre à combustion et les joints d étanchéité C...

Page 66: ... achat originale Il y a trois moyens faciles de nous faire parvenir cette information Adresse postale England s Stove Works Inc Technical Support Department P O Box 206 Monroe Virginia 24574 États Unis Télécopieur 1 434 929 4810 24 heures par jour Enregistrement en ligne Consultez notre page d enregistrement de la garantie sur notre site Web à http www englanderstoves com warranty warranty html LA...

Page 67: ...eignements sur l appareil Veuillez consulter l étiquette à l arrière du guide ou de la boîte pour remplir cette section IX Numéro de modèle Date d achat X Prix d achat XI Numéro de série Date de fabrication Questions relatives à l achat Comment avez vous entendu parler de notre produit Veuillez cocher l une des réponses suivantes De bouche à oreille Démonstration Sur Internet Autre À quel endroit ...

Reviews: