IMPORTANT!
READ AND FOLLOW
ALL
INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING
CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR
DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY QUESTIONS.
22
Adjusting Hopper Lid Latches
The seals around the top of the pellet hopper are important to safe and efficient operation of the
unit. The latches installed on these units are designed to pull the hopper lid tight against this seal.
Over the course of operation as these seals “wear in” and compress, the tension of the latches
should be tested periodically, and adjusted if necessary.
To adjust the lid latches, the following tools will be needed; two ½ inch wrenches, or a ½ inch
wrench and a ½ inch socket.
In order to adjust the latch, first (with the unit unplugged and cooled down) open the hopper lid
and then lock the latch in its closed position. Then take the ½ inch wrench and loosen the nut closest
to the latch. This nut is then adjusted closer to the lid itself to tighten the latch. After adjusting this nut
to the desired location, hold this nut in place with the ½ inch wrench, the tighten down the holding nut
on the end of the latch shaft with the ½ inch socket or second wrench to hold the latching assembly
in place
After tightening the latches, test the latches for proper tension by locking the lid down and lifting
each front corner of the lid. The lid should be firmly held down by the latches. Repeat the same
procedure if the latch is still not tight enough.
Important: Hopper Lid Latches must be checked periodically and kept
tight so the top is sealed to prevent back-burn.
Illu
stration 5
Hopper Lid Latch
Summary of Contents for 25-PDVC
Page 30: ......