Issue 1
ENKI®
WWW.HOUSEOFENKI.COM
6
MAINTENANCE
Should the filters need to be cleaned (10) or the non-return valves (9) some disassembly is
required.
§
Turn off water supply.
§
Follow drain down procedure.
§
Remove the mixer body from the tails (13) by releasing the grub screws (2) in the body, by using
an allen key.
§
Pull out the non-return valves, taking care not to damage them, clean under warm water or
replace if faulty.
§
Remove the filters from the tails and clean under warm water.
§
Replace all components in the order shown in the parts drawing.
§
Refit the tails ensuring they are fully inserted and secure the grub screws
§
Reconnect mixer, turn on water supply and check for leaks.
To replace the thermostatic cartridge:
§
Turn off water supply.
§
Remove handle cap (19A) and handle screw (1A).
§
Remove the handle (21) from the mixer and the nylon stop ring (14).
§
Remove the cartridge from the mixer body.
§
Clean or replace the cartridge as necessary, then replace, ensuring components are located
correctly to give correct maximum set temperature.
§
If recalibration is required follow instructions in ‘operation & setting’.
§
Once water supply is turned on check for leaks.
To replace the flow control valve:
§
Turn off water supply.
§
Remove handle cap (19), then handle screw (1).
§
Pull handle from the valve.
§
Remove valve from mixer, taking care not to disturb the pipework.
§
Clean and replace valve as necessary.
§
Replace all components, turn on water supply and check for leaks.
DRAIN DOWN PROCEDURE
Turn off water supply to valve. To drain down:
§
Remove the shower hose from the mixer.
§
Turn flow control valve to fully open.
§
Turn the temperature control fully clockwise, to drain all cold water, until water ceases flowing
from the mixer.
§
Turn the temperature control fully anti-clockwise and press the red button to continue the turn,
to drain the hot water, until water ceases to flow.
If the shower is to be left for long periods in conditions where temperatures can reach freezing, the
shower mixer should be removes. To do this, loosen the grub screws in the body and remove the mixer
from the tails.