CCS3100
25
User Manual R0.2
P009: Screw Pressure Warning Value (Screw Press
Warning):
= P014 + 0.6 BAR
2.2.2 Timing Parameters
All timing parameters that can be adjusted with the device are under this heading.
P021: Start Delay Time (Start Delay):
When the device receives a run command, it waits for the time entered to this parameter. The time remaining is
displayed on the right side of the screen.
P022: Stopping Time (Stopping Time):
When the device receives a stop command, it waits for the time entered to this parameter. The time remaining is
displayed on the right side of the screen.
P023: Air Discharge Time Duration (Air Discharge):
The expected time for the air pressure of the screw to drop after the compressor stops. During this time, the
compressor cannot be started.
P024: Idle Working Time Duration (Idle Working):
Specifies the idle run time before switching to the load when the device receives a run command.
P025: Reload Time Delay (PassAgain Onload):
During the idle run process that starts after the compressor running on load switches to idle, when the supply
pressure drops below the value entered to the "P003 Onload Pressure" parameter, the time specified with this
parameter is counted and then the device switches back to load.
P026: "Auto Waiting Delay(Auto Waiting):
The time to wait for the compressor to stop after reaching the switch to idle pressure is set with this parameter.
During this time, the compressor runs in idle mode. This parameter works on the condition that the value entered to
the "P160 Working Mode" parameter is selected as "Automatic".
P027: Power Fail Restart Delay Time (Power Cut):
In case of power faults that occur while the compressor is running, after the power is on again, the device switches
to run mode at the end of the time set with this parameter. By entering "0" value to the relevant parameter, the
automatic run function at power fault is cancelled.
P028: Star Feed Operation Time (Star Duration):
In the motor starting stage, running duration of star contactor of motor is adjusted with this parameter.
P029: Main Contactor Trigger Delay (Main Contactor):
After the star contactor is triggered, the main output is activated at the end of the time value entered to this
parameter.
P030: Start-Delta Transfer Time (Delta Transfer):
After the star contactor is deactivated, the delta contactor output is activated at the end of the time value entered to
this parameter.
P031: Pre-Heat On-Load Time (Preheat Onload):
Indicates the time to stay on load in the preheat running mode.
P032: Pre-Heat Off-Load Time (Preheat Idle):
Indicates the time to stay on load in the preheat running mode.
P033 Discharge Pressure Fail Alarm Delay (Line Press Alarm):
The expected delay time for line pressure alarm and warning errors.