background image

 

 
 
 
 

Website: www.enlitelighting.com      

Document version – EN-FLXXPIR_V1_17_ENG.DOC

 

UK 
Tel: +44 (0) 1727 83 66 11 
Email: uk@enlitelighting.co

 

France 
Tel: +33 (0) 1 30 11 11 88 
Email: france@enlitelighting.co

 

UAE 
Tel: +971 (0) 4 328 5489 
Email: uae@enlitelighting.com 

 
 

Australia 
Tel: +61 (0) 2 9882 6000 
Email: australia@enlitelighting.com 

 

South Africa 
Tel: +27 (0) 11 234 4878  
Email: SouthAfrica@enlitelighting.co

 

MAINS VOLTAGE HIGH POWER LED FLOODLIGHTS 

PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION 

LEAVE A COPY FOR THE USER / MAINTENANCE ENGINEER FOR FUTURE REFERENCE 

IMPORTANT INSTALLATION INFORMATION 

 

Installation should be carried out in accordance with the latest edition of the National Wiring Regulations. If in doubt, consult a 
qualified electrician.  

 

Input voltage - 240V 50Hz AC. 

 

These luminaires are not dimmable. 

 

These luminaires are IP65 and are protected against low pressure water jets. 

 

Powder coated luminaires are corrosion resistant but the finish may degrade in the long term if installed in coastal areas. 

 

Do not install in chlorinated areas, i.e. swimming pools. Do not install in saunas or steam rooms. 

 

There are no serviceable parts in these luminaires. 

 

Caution:  Do not stare directly into the LEDs in operation. These are high power LED floodlights and may be harmful to eyes. 

 

These luminaires are Class 1 and must be earthed 

INSTALLATION INSTRUCTIONS 

LUMINAIRES WITHOUT PASSIVE INFA-RED MOVEMENT DETECTOR

 

Always switch off the electricity supply at the distribution board before installation and maintenance 

1.

 

Select the required position for the luminaire. When installing ground mounted floodlights or spotlights do not install in areas 
that are subject to flooding and standing water. 

2.

 

Place the bracket in a suitable position and mark out the two holes before drilling. The guide below indicates what the distance 
should be between fixing holes. 

 

EN-FL10PIRA = 60MM 

 

EN-FL30PIRA = 105MM 

 

EN-FL50PIRA = 105MM 

3.

 

Use a suitable IP rated junction box to connect to the mains supply.  

Mains supply LIVE (Red or Brown) - to Luminaire Terminal marked ‘L’ (Brown) 
Mains supply NEUTRAL (Black or Blue) - to Luminaire Terminal marked ‘N’ (Blue) 
Mains supply EARTH (Green/Yellow) - to Luminaire terminal marked ‘E’ (Green/Yellow) 

4.

 

Switch on the power supply. 

 

LUMINAIRES WITH PASSIVE INFA-RED MOVEMENT DETECTOR

 

PRINCIPLE OF OPERATION 

 

The lamp switches on when the detector senses "warmth movement" in the surrounding area if it is dark enough.  

 

The PIR detector is equipped with three adjustment knobs. See Fig. 1.  

  

Time Adjustment 

For 10W,30W & 50W Versions

 

 

The period that the lamp stays on after no more movement is detected can be adjusted between 10 ±3secs to 7±2mins. 

 

Turn clockwise to increase the on period and vice versa.  

 
Daylight Adjustment 

For 10W,30W & 50W Versions 

 

The level of illuminance at which the PIR detector can be activated so that it can detect movement can be adjusted between 3 

and

2000 Lux. When adjusting to “Sun” mode the movement sensor works all day. When adjusted to “Moon” mode, the movement 

sensor does not work during the day time and will automatically work at night. 

 

Turn clockwise to increase the lighting value and vice versa.  

 

Sensitivity Adjustment 

For 30W & 50W Versions 

 

The sensitivity of the detector can be adjusted according to the use of the location. Detection range can be adjusted from low 

sensitivity (3m) to high sensitivity (6m). Turn clockwise to increase the sensitivity and vice versa. 

 

FIELD OF DETECTION 

The field of detection of the PIR sensor can be adjusted 180°

 

in the horizontal and vertical directions. By means of horizontal adjustment 

the permanent 180°

 

field of detection range can be reduced or expanded. See Fig. 2. By means of vertical adjustment the detection range 

e

 

Reviews: