background image

 

 

 

 

 

Repair Return Form 

 

Mailing Address: 
 

ENMET  

 

PO Box 979 

 

Ann Arbor, Michigan 48106 

 

Phone Number: 

734.761.1270 

FAX Number:  

734.761.3220 

 

Shipping Address: 
 

ENMET  

 

Attn:  Repair Department 

 

680 Fairfield Court 

 

Ann Arbor, Michigan 48108 

Your Mailing Address: 
 
 
 
 
 
 
 
 
 
 

 

Your Shipping Address: 
 
 
 
 
 
 
 
 
 
 

 

Contact Name: __________________________  Your Phone:  _______________________ 

Your PO/Reference Number: _______________  Your FAX: 

_______________________ 

Payment Terms: 

K

 COD 

(Check one) 

K

 VISA / MasterCard______________________ 

________ 

________ 

 

 

Card number 

Expiration 

Card Code 

 

K

 American Express______________________ 

________ 

________ 

 

 

Card number 

Expiration 

Card Code 

 

Name as it appears on the credit card___________________________________ 

Return Shipping Method: 

 

K

 UPS: 

K

 Ground 

K

 3 Day Select 

K

 Next Day Air 

K

 ND Air Saver 

K

 2-Day Air 

 

K

 UPS Account number: ________________________ 

 

K

 Federal Express: 

K

 Ground 

K

 Express Saver 

K

 P-1 

K

 Standard 

K

 2-Day Air 

 

K

 FedEx Account number: ________________________ 

Would you like ENMET to insure the return shipment? 
 

K

 No 

K

 Yes 

Insurance Amount: $_________________ 

Summary of Contents for EX-5100

Page 1: ...ENMET PO Box 979 Ann Arbor MI 48106 0979 www enmet com Manual part number 80003 096 MCN 416 04 03 09 EX 5100 COMBUSTIBLE Manual...

Page 2: ...gs 13 5 4 Sensor Replacement 13 6 0 REPLACEMENT PART NUMBERS 14 7 0 WARRANTY 14 List of Figures and Tables FIGURE 1 EX 5100 FEATURES 2 FIGURE 2 EX 5100 MOUNTING DIMENSIONS 3 FIGURE 3 TERMINAL POSITION...

Page 3: ...spection and after you have received written acknowledgment of the damage from the carrier contact ENMET Customer Service for return authorization and further instructions Have your Purchase Order and...

Page 4: ...instrument maintenance functions The switch locations are indicated by MENU and SELECT A magnetic field pulse is applied by momentarily putting the end of the magnet in proximity to the switch and the...

Page 5: ...tters Take into consideration environmental factors when deciding on S T location Avoid locations where the S T may be damaged by liquid immersion excessive heat or other know hazards Also take precau...

Page 6: ...e supplied J8 plug then attach to the J8 terminal See Figure 3 for locations J4 PLUG TERMINAL TO CONTROLLER WIRING Position Function 1 24 VDC power 2 GND 3 4 20 mA out 4 RS 485 D 5 RS 485 D Contact EN...

Page 7: ...l Display Mode If intended function Tap the magnet over SELECT switch Tap the magnet over the MENU switch to advance to the Zero procedure For adjusting Zero If intended function Tap the magnet over S...

Page 8: ...NOTE Software revision may cause variations of display output Example of Display Function The instrument Model EX 5100 The instrument Serial Number The instrument Software Revision IF the right most c...

Page 9: ...lay indicates Alarm 1 Set point Tap the magnet over the MENU button Display indicates Alarm 2 Set point Tap the magnet over the MENU button No Function for the SELECT button in this mode Display indic...

Page 10: ...asurement of target gas Hold the magnet over MENU switch for 2 5 seconds to enter the Maintenance Menu The Power Fault LED will flash Green Red to indicate the EX 5100 is in Maintenance Mode To exit t...

Page 11: ...nd Span functions are two separate procedures They operate independently of each other It is recommended that the Zero procedure be done prior to the Span procedure ENMET recommends at least quarterly...

Page 12: ...ne Calibration coefficients relative to Methane have been generated for over 30 different combustible hydrocarbons and solvents A partial list of these gases and vapors are listed in Table 3 Non Stand...

Page 13: ...ociated calibration gas cylinder to the regulator and calibration cover See to Figure 3 4 Open the valve to apply the calibration gas to the sensor 5 Watch for the signal level to stabilize Refer to T...

Page 14: ...the magnet over the SELECT switch The MENU switch changes digit indicated by underscore cursor The SELECT switch locks underscored digit and moves to next digit See Section 5 2 2 SELECT mA Span MENU S...

Page 15: ...see Figure 5 for a detailed maintenance menu flow chart Example of Display Function Normal Display Mode Measurement of target gas Hold the magnet over the MENU switch for 2 4 seconds to enter the Mai...

Page 16: ...means of transportation is requested during the warranty period the customer is responsible for the difference between the most economical means and the expedient mode ENMET shall not be liable for an...

Page 17: ...ult in processing delays ENMET charges a one hour minimum billing for all approved repairs with additional time billed to the closest tenth of an hour All instruments sent to ENMET are subject to a mi...

Page 18: ...OD Check one K VISA MasterCard______________________ ________ ________ Card number Expiration Card Code K American Express______________________ ________ ________ Card number Expiration Card Code Name...

Reviews: