3.
Fix the generator (W1) and the yaw
(W6) using M10x55 screws and DIN
9021 wide plain washers.
•
Tight them with a torque of 50 Nm.
4.
Put yaw cover (W12) in the yaw
(W6) - generator (W1) union and fix it
with two M4x16 countersunk allen
screws and four M6x20 allen screws.
5.7.4.
Rotor
1.
Put the generator facing up:
•
Lift up, just a bit, the tower in order
to rotate the generator to the
correct position.
•
Rotate generator to put it facing up
as shown in the figure.
•
Keep holding the generator and lift
down the tower until it rests
properly in a base.
2.
Fit the bushing (W10) to the hub
(W9) with a nº 50 spanner.
Check that the bushing is
fully tightened and the flat
surfaces are in contact.
3.
Place the hub on the generator
shaft.
W12
W9
W10
Grower washer