background image

USER MANUAL V1.12 

EnOcean GmbH 
Kolpingring 18a 
82041 Oberhaching 
Germany 

Phone +49.89.67 34 689-0 
Fax +49.89.67 

34 

689-50 

info@enocean.com 
www.enocean.com 

Subject to modifications 
PTM 230 User Manual V1.12 
June 4, 2008 2:02 PM 
Page 10/12 

 

PTM 230 

3.2

 

Transmission Range 

 

The main factors that influence the system transmission range are type and location of the 

antennas of the receiver and the transmitter, type of terrain and degree of obstruction of 

the link path, sources of interference affecting the receiver, and “dead” spots caused by 

signal reflections from nearby conductive objects. Since the expected transmission range 

strongly depends on these system conditions, range tests should categorically be per-

formed before notification of a particular range that will be attainable by a particular appli-

cation. 

 

The following figures for expected transmission range are considered by using the PTM 100 

radio transmitter module and the RCM 110 or RCM 120 radio receiver module with the pre-

installed whip antennas and may be used as a rough guide only: 

 

 

10 m

 in industrial applications with metal in the vicinity 

 

30 m

 for obstructed environment (e.g., through two brick walls inside a building) 

 

300 m

 for unobstructed environment (“free field”) 

 

Further notes to determine the transmission range within buildings are available as down-

load from 

www.enocean.com

 

 

3.3

 

Approval Requirements 

 
The modules bear the EC conformity marking CE and conform to the R&TTE EU-directive on 
radio equipment. The assembly conforms to the European and national requirements of 

electromagnetic compatibility. The conformity has been proven and the corresponding do-
cumentation has been deposited at EnOcean. The modules can be operated without notifi-

cation and free of charge in the area of the European Union, in Switzerland, in Cyprus, in 
Czech, in Estonia, in Hungary, in Latvia, in Lithuania, in Malta, in Poland, in Romania and in 

Slovenia. The following provisos apply: 
 

ƒ

 

EnOcean RF modules must not be modified or used outside their specification 
limits. 

ƒ

 

EnOcean RF modules may only be used to transfer digital or digitized data. 

Analog speech and/or music are not permitted. 

ƒ

 

The final product incorporating EnOcean RF modules must itself meet the es-

sential requirement of the R&TTE Directive and a CE marking must be affixed 
on the final product and on the sales packaging each. Operating instructions 

containing a Declaration of Conformity has to be attached.

 

ƒ

 

If transmitters are used according to the regulations of the 868.3 MHz band, a 

so-called “Duty Cycle” of 1% per hour for each transmitter must not be ex-
ceeded (also see chapter 2.3.1). 

Summary of Contents for PTM 230

Page 1: ...pingring 18a 82041 Oberhaching Germany Phone 49 89 6734 689 0 Fax 49 89 6734 689 50 info enocean com www enocean com Subject to modifications PTM 230 User Manual V1 12 June 4 2008 2 02 PM Page 1 12 Transmitter Module PTM 230 June 4 2008 ...

Page 2: ...nOcean GmbH All Rights Reserved Important This information describes the type of component and shall not be considered as assured characteristics No responsibility is assumed for possible omissions or inaccuracies Circuitry and specifications are subject to change without notice For the latest product specifica tions refer to the EnOcean website http www enocean com As far as patents or other righ...

Page 3: ...mental Conditions 5 1 5 Ordering Information 5 2 FUNCTIONAL DESCRIPTION 6 2 1 Block Diagram 6 2 2 Pin Description and operational characteristics 6 2 3 PTM 230 Radio Telegram 7 2 3 1 Frequency range and transmission cycle allowed 7 2 3 2 Modulation process 7 2 3 3 Transmission timing 7 3 APPLICATION INFORMATION 9 3 1 Antenna Mounting 9 3 2 Transmission Range 10 3 3 Approval Requirements 10 4 APPLI...

Page 4: ...rinciple When a short energy pulse is supplied to the PTM 230 module an RF telegram is transmit ted including a 32 bit module ID and the polarity of the supply voltage In addition the in formation of 2 inputs is transmitted With the 2 inputs one rocker of a PTM 200 can be simulated 1 2 Features Overview Power supply external electro dynamic power generator or energy pulse Frequency Transmission po...

Page 5: ...difications PTM 230 User Manual V1 12 June 4 2008 2 02 PM Page 5 12 PTM 230 1 3 Mechanical Interface Figure PCB Dimensions in mm view on pads 1 4 Environmental Conditions Operating temperature 25 C up to 65 C Storage temperature 25 C up to 65 C Humidity 0 to 93 r h non condensing no IP class 1 5 Ordering Information Type Ordering Code PTM 230 S3011 A230 PWR1 PWR2 ...

Page 6: ...lse 11ms voltage measured with module connected required pulse width depends on voltage pulse shape and source impedance SW1 SW2 Digital inputs for simulation of O button and I button signal of a PTM 200 Connect SW1 to Vcc for simu lation of I button Connect SW2 to Vcc for simu lation of O button Maximum wire length to Vcc 3cm each The signal at SW1 and SW2 must be available 100µs before and 10ms ...

Page 7: ...considered including three subtelegrams 2 3 2 Modulation process As modulation process EnOcean uses incoherent amplitude modulation ASK Digital am plitude modulation enables the implementation of very efficient energy saving transmitters because only the 1 bits are transferred At the same interference signal level the trans mission security of the alternative FSK method is identical to that of the...

Page 8: ...230 transmits an EnOcean radio telegram which is provided at the serial output of a RCM 120 or TCM 120 module with the following parameters Unique factory programmed 32bit ID Data2 Data1 Data0 0 Data3 and Status as follows P polarity X reserved R repeater counter The polarity P is defined as follows SW1 SW2 ORG Data3 Status open open 0x05 000PXXXX XX10RRRR Vcc open 0x05 000P0000 XX11RRRR open Vcc ...

Page 9: ...nna enables very compact unit with good radio characteristics For mounting the antenna the following notes should be considered to optimize the system performance Mounting a 1 4 wave whip antenna For good transmit performance great care must be taken about the space immediately around the antenna since this has a strong influence on screening and detuning the an tenna The antenna should be drawn o...

Page 10: ...obstructed environment free field Further notes to determine the transmission range within buildings are available as down load from www enocean com 3 3 Approval Requirements The modules bear the EC conformity marking CE and conform to the R TTE EU directive on radio equipment The assembly conforms to the European and national requirements of electromagnetic compatibility The conformity has been p...

Page 11: ...yand Ordering Information Type EnOcean Ordering Code Scope of supply EVA 100 H3004 G100 Evaluation Board EVA PCB EnOcean radio modules PTM 100 incl Rock er Model STM 100 RCM 110 and RCM 120 CD with PC link Monitor Software and de tailed kit documentation Wall power supply for EVA PCB Convenient equipment case Symbol Function Adaptor Female jack for power supply RCM 100 Female header for plug in RC...

Page 12: ...lpingring 18a 82041 Oberhaching Germany Phone 49 89 6734 689 0 Fax 49 89 6734 689 50 info enocean com www enocean com Subject to modifications PTM 230 User Manual V1 12 June 4 2008 2 02 PM Page 12 12 PTM 230 5 DECLARATION OF CONFORMITY ...

Reviews: