background image

USER MANUAL V1.12 

EnOcean GmbH 
Kolpingring 18a 
82041 Oberhaching 
Germany 

Phone +49.89.67 34 689-0 
Fax +49.89.67 

34 

689-50 

info@enocean.com 
www.enocean.com 

Subject to modifications 
PTM 230 User Manual V1.12 
June 4, 2008 2:02 PM 
Page 2/12 

 

PTM 230 

REVISION HISTORY 

The following major modifications and improvements have been made to the first version of 
this document: 

 

 

No 

Major Changes 

0.91 

Requirements for energy converter added in 2.1 

0.92 

Section 3.1 Antenna Mounting added 

0.93 

Drawing for contact pads added 

0.95 

Specification for energy generator modified, tolerance in PCB dimensions modified 

0.96 

Minimal switching interval defined in 1.2 and 1.1; change in 2.3.2 maximum 3 

sub-telegrams are transmitted; hole diameter changed to 2mm in 1.3; antenna 
end should be insulated in 3.1 

1.0 

Mechanical drawing updated; additional pads for rocker information described; 

telegram content specified; minimal switching time changed to 50ms. 

1.01 

Humidity range reduced to 93% max. 

1.02 

Minor changes 

1.03 

Editorial changes 

1.1 

Energy pulse shape modified 

1.11 

Declaration of conformity added 

1.12 

Requirements for energy pulse modified 

 

Published by EnOcean GmbH, Kolpingring 18a, 82041 Oberhaching, Germany 

www.enocean.com, info@enocean.com, phone ++49 (89) 6734 6890 

 

© EnOcean GmbH 

All Rights Reserved 

 

 

Important! 

 

This information describes the type of component and shall not be considered as assured 

characteristics. No responsibility is assumed for possible omissions or inaccuracies. Circuitry 
and specifications are subject to change without notice. For the latest product specifica-
tions, refer to the EnOcean website: http://www.enocean.com. 

As far as patents or other rights of third parties are concerned, liability is only assumed for 
modules, not for the described applications, processes and circuits. 

EnOcean does not assume responsibility for use of modules described and limits its liability 
to the replacement of modules determined to be defective due to workmanship. Devices or 

systems containing RF components must meet the essential requirements of the local legal 
authorities. 

The modules must not be used in any relation with equipment that supports, directly or 
indirectly, human health or life or with applications that can result in danger for people, 
animals or real value. 

Components of the modules are considered and should be disposed of as hazardous waste. 
Local government regulations are to be observed. 

Packing: Please use the recycling operators known to you. By agreement we will take pack-
ing material back if it is sorted. You must bear the costs of transport. For packing material 

that is returned to us unsorted or that we are not obliged to accept, we shall have to in-
voice you for any costs incurred. 

Summary of Contents for PTM 230

Page 1: ...pingring 18a 82041 Oberhaching Germany Phone 49 89 6734 689 0 Fax 49 89 6734 689 50 info enocean com www enocean com Subject to modifications PTM 230 User Manual V1 12 June 4 2008 2 02 PM Page 1 12 Transmitter Module PTM 230 June 4 2008 ...

Page 2: ...nOcean GmbH All Rights Reserved Important This information describes the type of component and shall not be considered as assured characteristics No responsibility is assumed for possible omissions or inaccuracies Circuitry and specifications are subject to change without notice For the latest product specifica tions refer to the EnOcean website http www enocean com As far as patents or other righ...

Page 3: ...mental Conditions 5 1 5 Ordering Information 5 2 FUNCTIONAL DESCRIPTION 6 2 1 Block Diagram 6 2 2 Pin Description and operational characteristics 6 2 3 PTM 230 Radio Telegram 7 2 3 1 Frequency range and transmission cycle allowed 7 2 3 2 Modulation process 7 2 3 3 Transmission timing 7 3 APPLICATION INFORMATION 9 3 1 Antenna Mounting 9 3 2 Transmission Range 10 3 3 Approval Requirements 10 4 APPLI...

Page 4: ...rinciple When a short energy pulse is supplied to the PTM 230 module an RF telegram is transmit ted including a 32 bit module ID and the polarity of the supply voltage In addition the in formation of 2 inputs is transmitted With the 2 inputs one rocker of a PTM 200 can be simulated 1 2 Features Overview Power supply external electro dynamic power generator or energy pulse Frequency Transmission po...

Page 5: ...difications PTM 230 User Manual V1 12 June 4 2008 2 02 PM Page 5 12 PTM 230 1 3 Mechanical Interface Figure PCB Dimensions in mm view on pads 1 4 Environmental Conditions Operating temperature 25 C up to 65 C Storage temperature 25 C up to 65 C Humidity 0 to 93 r h non condensing no IP class 1 5 Ordering Information Type Ordering Code PTM 230 S3011 A230 PWR1 PWR2 ...

Page 6: ...lse 11ms voltage measured with module connected required pulse width depends on voltage pulse shape and source impedance SW1 SW2 Digital inputs for simulation of O button and I button signal of a PTM 200 Connect SW1 to Vcc for simu lation of I button Connect SW2 to Vcc for simu lation of O button Maximum wire length to Vcc 3cm each The signal at SW1 and SW2 must be available 100µs before and 10ms ...

Page 7: ...considered including three subtelegrams 2 3 2 Modulation process As modulation process EnOcean uses incoherent amplitude modulation ASK Digital am plitude modulation enables the implementation of very efficient energy saving transmitters because only the 1 bits are transferred At the same interference signal level the trans mission security of the alternative FSK method is identical to that of the...

Page 8: ...230 transmits an EnOcean radio telegram which is provided at the serial output of a RCM 120 or TCM 120 module with the following parameters Unique factory programmed 32bit ID Data2 Data1 Data0 0 Data3 and Status as follows P polarity X reserved R repeater counter The polarity P is defined as follows SW1 SW2 ORG Data3 Status open open 0x05 000PXXXX XX10RRRR Vcc open 0x05 000P0000 XX11RRRR open Vcc ...

Page 9: ...nna enables very compact unit with good radio characteristics For mounting the antenna the following notes should be considered to optimize the system performance Mounting a 1 4 wave whip antenna For good transmit performance great care must be taken about the space immediately around the antenna since this has a strong influence on screening and detuning the an tenna The antenna should be drawn o...

Page 10: ...obstructed environment free field Further notes to determine the transmission range within buildings are available as down load from www enocean com 3 3 Approval Requirements The modules bear the EC conformity marking CE and conform to the R TTE EU directive on radio equipment The assembly conforms to the European and national requirements of electromagnetic compatibility The conformity has been p...

Page 11: ...yand Ordering Information Type EnOcean Ordering Code Scope of supply EVA 100 H3004 G100 Evaluation Board EVA PCB EnOcean radio modules PTM 100 incl Rock er Model STM 100 RCM 110 and RCM 120 CD with PC link Monitor Software and de tailed kit documentation Wall power supply for EVA PCB Convenient equipment case Symbol Function Adaptor Female jack for power supply RCM 100 Female header for plug in RC...

Page 12: ...lpingring 18a 82041 Oberhaching Germany Phone 49 89 6734 689 0 Fax 49 89 6734 689 50 info enocean com www enocean com Subject to modifications PTM 230 User Manual V1 12 June 4 2008 2 02 PM Page 12 12 PTM 230 5 DECLARATION OF CONFORMITY ...

Reviews: