43
EN
Problem
Possible cause
Solution
Too much ice on the panel
at the bottom of the refri-
gerated compartment
The door is not hermetically closed
Close the door and check that nothing is preventing it
from closing tightly
Check the condition of the door seal. If it is worn, con-
tact an authorised dealer to have it replaced
The door is being kept open for too long
Reduce unnecessary door openings
An excessively low temperature has been set
Change the temperature as instructed in "
Changing
the temperature SETPOINT
" on page 14
Time between defrosts is too long
Perform a manual defrost as instructed in "
Defrostin-
g
"on page 14
Water at the bottom of the
refrigerated compartment The condensate drain slot is blocked
Clean the condensate drain as instructed in "
Cleaning
the interior of the cabinet
" on page 20
Noise or vibration
Feet badly adjusted
Adjust the feet correctly
Odours inside the refrige-
rated compartment
The refrigerated compartment is dirty
Clean the refrigerated compartment as instructed in "
Cleaning the interior of the cabinet
"on page 20
m
IMPORTANT!
–
After installation of the appliance, at least 12 hours are needed to achieve normal functioning.
During this period the compressor may run for a long time or may switch on and off frequently.
–
Gurgles from the refrigeration system are to be considered normal.
4.7
Technical assistance and spare parts
If necessary, contact the manufacturer or an authorised dealer to have any servicing, repair or replacement work completed rapi-
dly and correctly by specialist personnel using purpose-made equipment.
l
IMPORTANT!
In all dealings with the technical assistance service always quote the details given on the applian-
ce's nameplate and:
–
the nature of the problem
–
the model of the appliance
–
the serial number of the appliance
–
your address and telephone number.
4.8
Disposal
Dispose of all packaging material in conformity to applicable law.
At the end of its useful life, the appliance must be disposed of according to legislation governing the
disposal of industrial and special waste. Unplug the appliance and cut off the power cable to render it
unusable. Also make it impossible to close the door.
When disposing of the appliance, avoid damaging the refrigerant pump and take particular care to avoid
loss of refrigerant into the environment. Dispose of the appliance through a collection centre authorised
to dispose of refrigerants.