38. CLEANING THE DISPENSER
Before starting to clean the Dispenser carefully read the warnings
section (para.1) and the scheduled maintenance frequencies table
(para. 48). The use of gloves is recommended for performing all the
cleaning operations.
39. CLEANING OF THE EXTERNAL PARTS
During this cleaning operation always disconnect the power cord.
Gently use a
soft, non-abrasive cloth, slightly dampened with warm water and wipe all the sur-
faces - front/side/rear/top. Avoid cleaning the command keyboard and the display
(
A
) before having read the relevant paragraph (para.40). Finally, dry thoroughly with
a dry cloth.
40. CLEANING THE COMMAND KEYBOARD AND DISPLAY
During this cleaning operation always disconnect the power cord.
Use a soft, dry and non-abrasive cloth as
the keyboard is sensitive to moisture.
While cleaning exert light pressure
to avoid the keyboard being irreparably damaged.
MAINTENANCE
41. CLEANING THE DRIP GRILL WITH
TRAY AND REAR VENTILATION GRILL
A few drops of wine always fall from the dispensing nozzle into the relevant
drip
grill with tray
(
C
). To remove the tray, open the door (
B
) and lift the drip grill keep-
ing it in a horizontal position. Close the door again. Then drain off the liquid from
the tray and clean it using a non-abrasive sponge with water at a maximum tem-
perature of 40°C/104°F and possibly a mild detergent. Finally, rinse thoroughly with
water, dry completely and replace in position.
Do not wash the tray in a dishwasher.
Do not use the Dispenser without the tray. Always check that there is no liquid
or condensate inside the Dispenser under the drip tray. In this case, discon-
nect the Dispenser from the power supply network
, gently clean with a soft,
non-abrasive, cloth slightly dampened with warm water and possibly a mild deter-
gent. Finally, dry thoroughly with a dry cloth.
Also pay special attention to the removal of dust and any other residue from the
rear aeration grills (D)
to allow correct air circulation, which is essential for good
operation and therefore to ensure improved longevity of the thermoelectric refriger-
ation system
(O).
Never use paper or material that could scratch.
Where cleaning the grills described above (C, D) is not sufficient to restore
proper functioning of the refrigeration system, it is advisable to contact an au-
thorised Technician or the Retailer to perform complete and precise cleaning
of the refrigeration system (O).