eno
one 2/r - user manual
REV.05
49
PROBLEM
POSSIBLE CAUSE
SOLUTION
The wine is not
being dispensed
or it is not being
dispensed in the
amount set
The bottle is not
correctly inserted.
Replace the mouth of the
bottle on the seal of the cap
tap (para.20)
The rubber straw is not prop-
erly inserted on plug tap or
is not inserted
Lower the bottle and insert
the straw on the plug tap
unit until it is fully inserted
(para. 20)
The rubber straw is exces-
sively long or short or it is
obstructed
Use a straw of the correct
length, ensuring correct in-
sertion (paras. 18 and 20)
The dispensing gas circuit
is finished or the supply
pressure
is insufficient
Replace the inert gas cylinder
(para.14)
The filter of the rubber straw
is clogged with wine sedi-
ment
Clean the rubber straw
(para.43)
Storing of all the doses dur-
ing the programming phase
was not completed.
Repeat dispensing storage
from all the dose buttons (pa-
ras. 28 or 29 or 30)
The dispenser unit is blocked Sanitise the dispenser unit
and then wash the dispenser
unit (para.44)
The seal of the cap tap is
damaged or out of position
Replace the seal with the one
supplied (para. 6). Reposition
the seal
The gas connection pipe
is flattened at one or several
points
Request a new connection
pipe from the retailer
TROUBLESHOOTING
to be continued