Connect the cables.
Feed all cables into the charger unit through the cable block.
1) Lead the power cables through the grommet with the attachable
bridge component that provides tensile protection. The bridge
component has already been removed and will be attached later.
Three phase configuration
One phase configuration
1
2
3
4
Three phase configuration (No N-cable)
2) Connect each cable to its corresponding cable slot using the
locking system: lift the slot lid, insert the cable and close the slot
lid.
The charger unit contains labelled cable slots
. In order from
left to right, cables should be attached to the slots as follows:
N slot: blue cable
L3 slot: grey cable
L2 slot: black cable
L1 slot: brown cable
PE slot: yellow-green cable
21