The Outputs are configurable for the operator to choose which output function to use with the desired
output type as shown below.
•
Relay [10A] Form C
•
Digital Out [5V, 200mA]
•
Digital Out [B+, 2A]
•
Digital Out [B-, 1A]
•
Analog Out [0-5VDC] Dedicated for analog throttling
NOTE:
Although the functionality exists to set all analog and digital inputs to the same
function, Enovation Controls strongly advises against this.
(Main Menu, page 2)
Application Configuration
The Application Configuration menu is where an operator will set
up the controller’s Auto Start Functions and
Auto Throttle Methods, if the intended use is an auto start and/or auto throttling controller. Depending on which
application is chosen in the menu, there are certain auto start functions and auto throttling methods hidden
that are not pertinent to the application chosen. This automatic hiding feature allows for a simpler, more
intuitive controller menu in the MPC-20. Review Application Configuration under the Menu Glossary section
of this manual for the full list and definition of each setting.
Pump All Purpose
The Pump All Purpose application houses most of the auto start functions and auto throttling methods
in the controller. This application is the most versatile application thus requiring so many combinations
of settings for the operator to choose.
The auto start functions and auto throttle methods to choose from are listed below.
Auto Start/Stop Functions
•
Local Key Start
•
Single Contact
•
Two Contact Maintained
•
Two Contact Momentary
•
Pressure Transducer
•
Level Transducer
•
Flow Transducer
Auto Throttle Methods
•
Running Loaded