Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version:
2.9.23042; BTL: 02.09.10015.00]
Section 40
43
00-02-0996
2019-06-13
Application Configuration
(Medium Security)
Application
–
(Medium Security):
Factory set to Pump All Purpose
Pump All Purpose
–
houses most all auto start functions and auto throttling methods of the controller.
This application is the most versatile application thus requiring so many combinations of settings for
the operator to choose.
Center Pivot / Linear Irrigation
–
houses the auto start functions and auto throttle methods meant to
be used on center pivot and linear movement irrigation applications.
Air Compressor
–
houses the auto start functions and auto throttle methods meant to be used on all
engine-driven air compressor applications. The MPC-20-R2 allows for the compressor to start/stop
and maintain a desired pressure during operation.
Hose Reel Irrigation
–
houses the auto start functions and auto throttle methods meant to be used
on hose reel irrigation systems. The MPC-20-R2 allows for the hose reel pump to auto start with
several methods, including the Local Key Start which may be the most used in this application. The
key feature of this application is the auto throttling method. This feature allows the controller to manage
the pump’s throttle in order to maintain a pressure in the hose during irrigation.
Frost Protection
–
houses the auto start functions and auto throttle methods meant to be used on
frost protection systems. This application allows for wind machine, sprinkler or other forms of frost
protection using single contact or a temperature transducer.
Auto Start / Stop Function
–
(Medium Security):
Factory set to Two Contact Maintained.
Single Contact:
(Center Pivot/Linear Irrigation, Air Compressor, Hose Reel Irrigation, Frost
Protection)
Local Start Key:
(Center Pivot/Linear Irrigation, Hose Reel Irrigation) referring to the green start
button as in manual mode. This setting is used when auto start is not desired, but auto throttling is
required.
Two Contact Maintained:
(Center Pivot/Linear Irrigation, Air Compressor, Hose Reel Irrigation)
Two Contact Momentary:
(Center Pivot/Linear Irrigation, Air Compressor, Hose Reel Irrigation)
Pressure Transducer:
(Air Compressor, Hose Reel Irrigation) read
Pressure Type
in detail
below
under Pressure Transducer menu for understanding of setup.
Level Transducer:
(Pump All Purpose) read
Level Type
in detail
below under Level Transducer menu
for understanding of setup.
Flow Transducer:
(Pump All Purpose) read
Flow Type
in detail
below under Flow Transducer menu
for understanding of setup.
Temperature Transducer:
(Frost Protection)
Auto Throttle Method
–
(Medium Security):
Factory set to Running Loaded.
Running Loaded RPM
(Pump All Purpose, Center Pivot/Linear Irrigation, Air Compressor, Hose Reel
Irrigation, Frost Protection)