Target RPM Step Size
–
(Medium Security):
step size of the target RPM when increasing and decreasing.
The actual rate of change is much higher when throttling in auto vs. manually with the push buttons.
Factory set to 25 RPM.
Throttle Deadband RPM
–
(Medium Security):
(only appears when Pulse Inc/Dec or Analog, 0-5 VDC is
chosen for the Throttle Type) format of # RPM. Plus/minus value added to the target to provide a range of
RPM during which the throttle is not active. No throttling will occur when the engine RPM is within the RPM
deadband.
Factory set to 25 RPM.
Throttle Inc/Dec Analog
– (High Security): (only appears when Analog is chosen) format of # mS. The
amount of time to pulse the throttle. Increase this value for faster engine response, or decrease this value
for slower engine response.
Factory set to 50 mS.
Throttle Inc/Dec Pulse
–
(High Security):
(only appears when Pulse Inc/Dec is chosen) format of # mS.
The amount of time to pulse the throttle. Increase this value for faster engine response, or decrease this
value for slower engine response.
Factory set to 50 mS.
Throttle Inc/Dec Pulse Delay
–
(High Security):
(only appears when Pulse Inc/Dec is chosen) format of #
mS. The amount of delay time before pulsing the throttle. Increase this value for slower engine response,
or decrease this value for faster engine response.
Factory set to 250 mS.
Analog Minimum Value
–
(High Security):
(only appears when analog throttle type is chosen) analog
throttle output will not go lower than this set point.
Factory set to .50 V.
Analog Maximum Value
–
(High Security):
(only appears when analog throttle type is chosen) analog
throttle output will not go higher than this set point.
Factory set to 4.5 V.
Throttle Inc Rate
–
(Medium Security): rate the engine is signaled to increase in RPM. When using
Thomson Engine Throttle Type the setting will be shown as a gain value.
Factory set to 100 RPM/s.
Throttle Dec Rate
–
(Medium Security): rate the engine is signaled to decrease in RPM. When using
Thomson Engine Throttle Type the setting will be shown as a gain value.
Factory set to 100 RPM/s.
Torque Control
–
(High Security)
:
when Volvo is selected as the engine manufacturer this menu item
becomes active. This menu allows for enabling or disabling torque control of the engine as well as the limit
percentage of control.
Enable/Disable Torque Control:
Factory set to Disabled
Torque Limit Control:
Torque Control
Factory set to 125%
Set Throttle to Zero
–
(Low Security): This setting allows to zero the Thomson actuator when selected as
the Engine Throttle Type.
Throttle Direction
–
(Low Security): This setting allows the user to set whether the Thomson actuator
Extends to Increase the RPM or Extends to Decrease the RPM.
Factory set to Extend to Decrease.
Input / Output Menu
(Medium Security)
Digital Inputs (1-6)
–
(Medium Security): for each of the digital inputs, the ability to select the following
parameters exists: