Charge the unit 

Before using the EnozoWASH for the first time, charge the battery. The first charge may take up 
to 8-10 hours. When charging, the red LED on the EnozoWASH will flash. The charge is complete 
when the red LED stops flashing. Note: The device will not operate while connected to the 
battery charger. 

Connect the battery charger to a 100-240 VAC 50/60 Hz power source. Connect the battery 
charger power cord to the EnozoWASH. The system is powered by a 7.4V Li-Ion rechargeable 
battery pack. A 100 to 240 VAC 50/60 Hz charger is included. Use only the charger that is 
provided.  

 

Connect the Nozzle 

Connect the nozzle to the water outlet fitting. The water outlet fitting is the one closest to the 
trigger and LED indicators. Screw the nozzle until it is finger tight. Further tighten with a wrench 
if water leaks from the fitting.  

 

Connect to a Water Source 

The EnozoWASH comes equipped with 

¾”

 NPT fittings installed into it. Also included are fittings 

that be used to connect to a portable backpack tank or directly to a hose. The water supply that 
is used must provide be pressurized for water to flow through the sprayer. The water supply 
should only be connected to the water inlet fitting, which is the fitting that is furthest away from 
the trigger and LED indicators.  

Connect to a backpack tank

 - Some backpack tanks will have fittings that will connect 

directly to the ¾” fitting. If the desired backpack does not have the fittings, then the 

included barbed fitting can be used. Connect one end of the barbed fitting to the water 
inlet fitting of the EnozoWASH. Connect the tubing from the backpack to the barbed 
fitting, using the hose clamp to tighten.    

 

Summary of Contents for SW-200

Page 1: ...EnozoWASH User Manual ...

Page 2: ...AL DATA 4 3 DESCRIPTION 5 3 1 DESCRIPTION 5 3 2 KEY COMPONENTS 5 3 3 OPERATING INSTRUCTIONS 7 4 PREVENTATIVE MAINTENANCE CLEANING 8 5 TROUBLESHOOTING 8 6 DECOMMISSIONING STORAGE DISPOSAL 9 6 1 Storage 9 6 2 Disposal 9 7 SERVICE 10 7 1 Service and Warranty 10 7 2 Service Network U S Canada 10 ...

Page 3: ... It may only be used for it intended purpose Product is intended for commercial and industrial use Do not remove warning labels from unit Use only clean potable water with this product Do not immerse in water Clean exterior of unit with soft cloth Do not use harsh or abrasive cleaners Do not add any cleaning chemicals to the water supply that is used 1 2 CAUTION Do not spray towards eyes In case o...

Page 4: ...thout a water connection Doing so may damage the ozone cell and render the product useless 2 TECHNICAL DATA Specifications EnozoWASH Materials ABS Plastic Weight 4 lbs 1 8 kg Dimensions 36 L x 4 W x 5 H Maximum Water Pressure 100 psi Water Temperature 40 F to 86 F 4 C to 30 C Water Quality Hardness 250 ppm CaCO3 May Extend Life of Unit Conductivity 50µS cm Do not use distilled or deionized water A...

Page 5: ...rd non porous surfaces and destroys organic odors The electrolytic cell inside the EnozoWASH is created from a proprietary diamond process technology and generates ozone on demand from water itself 3 2 KEY COMPONENTS 1 Adjustable Spray Nozzle 2 Water Outlet 3 Diamond Cell 4 Battery and Electronics 5 Indicator LEDs 6 Spray Trigger 7 Charging Port 8 Water Inlet Note Product may vary from illustratio...

Page 6: ...d compliance to regulations Dependable On Demand Solution Ozone O3 is activated as needed Runs on long lasting rechargeable batteries Requires only clean potable water User friendly lights when sanitizer is active Alternative Leaves behind no chemical residue Compatible with all surfaces where water may be used Eliminates potential errors with mixing or diluting Ingredients by weight o 99 9998 Wat...

Page 7: ...he one closest to the trigger and LED indicators Screw the nozzle until it is finger tight Further tighten with a wrench if water leaks from the fitting Connect to a Water Source The EnozoWASH comes equipped with NPT fittings installed into it Also included are fittings that be used to connect to a portable backpack tank or directly to a hose The water supply that is used must provide be pressuriz...

Page 8: ...e first charge can take up to 10 hours To prime the cell spray the unit for 2 minutes or unit the blue lights stops flashing and remains solid The cell is now good to use This process may have to be repeated if the device sits unused for an extended period 4 PREVENTATIVE MAINTENANCE CLEANING 1 Charge the EnozoWASH nightly to ensure full battery capacity the next day 2 Clean the unit with moistened...

Page 9: ...afety regulations Dispose of the appliance in accordance with local regulations It is essential that you observe the laws and regulations for the disposal of environmentally harmful substances Obtain detailed information about their disposal such substances include plastics and decommissioned battery packs and Li ion batteries Special regulations apply when disposing of used electrical appliances ...

Page 10: ...ed repairs or installation by unauthorized persons alterations abuse fire flood or acts of nature Additionally this warranty may be voided in the case of Failure to follow instructions for use care or maintenance Removal alteration or defacing of the serial number and other labels Service by a non authorized service company Mechanical damage Use with any other fluids other than clean potable water...

Reviews: