Page 8
PEDESTAL INSTALLATION GUIDE
INSTALLATION REQUIREMENTS
Refer to the EVSE documentation to determine the appropriate circuit breaker current capacity. All conductors must be appropriately sized for the
EVSE current capacity, in accordance with local and NEC electrical codes.
REQUIRED EQUIPMENT FOR A SINGLE-MOUNT PEDESTAL WITH ONE TESLA® WALL CONNECTOR (ONE EVSE
PEDESTAL):
•
One (1) TESLA® Wall Connector (EVSE). NOTE: The TESLA® Wall Connector comes with a Cable Organizer for Wall Mounting
Purposes only. This cable organizer is not utilized on the Pedestal Mounting System.
•
One (1) ClipperCreek TESLA® EVSE Pedestal Kit, ClipperCreek part number 0300-00-022.
•
One (1) dedicated 208 or 240 VAC branch circuits.
•
One (1) circuit breaker, appropriately sized with respect to the charging capacity of each EVSE.
•
Two (2) Live Line conductors with enough length to comfortably pull all the way through and above the top of the pedestal.
•
One (1) Ground Line conductor with enough length to comfortably pull all the way through and above the top of the pedestal.
•
Conduit sized to fit all three conductors.
•
Four (4) Anchor Bolts with Nuts and Washers
REQUIRED EQUIPMENT FOR A DUAL-MOUNT PEDESTAL WITH TWO TESLA® WALL CONNECTORS (TWO EVSE’S PER
PEDESTAL):
•
Two (2) TESLA® Wall Connectors (EVSE’s). NOTE: The TESLA® Wall Connector comes with a Cable Organizer for Wall
Mounting Purposes only. This cable organizer is not utilized on the Pedestal Mounting System.
•
One (1) ClipperCreek TESLA® EVSE Pedestal Kit, ClipperCreek part number 0300-00-022.
•
One (1) ClipperCreek Dual-Mount TESLA® Mounting Plate Kit, ClipperCreek part number 0300-00-021.
•
Two (2) dedicated 208 or 240 VAC branch circuits.
•
Two (2) circuit breakers, appropriately sized with respect to the charging capacity of each EVSE.
•
Two pairs (2x2) Live Line conductors (one pair for each EVSE) with enough length to comfortably pull all the way through and
above the top of the pedestal.
•
Two (2) Ground Line conductors (One for each EVSE) or a single bonded Ground Line with enough length to comfortably pull all
the way through and above the top of the pedestal.
•
Conduit sized to fit all Live Line and Ground Line conductors.
•
Four (4) Anchor Bolts with Nuts and Washers
REQUIRED EQUIPMENT FOR A COMBO DUAL-MOUNT PEDESTAL WITH ONE TESLA® WALL CONNECTOR AND ONE
HCS CHARGING STATION (TWO EVSE’S PER PEDESTAL):
•
One (1) TESLA® Wall Connector (EVSE). NOTE: The TESLA® Wall Connector comes with a Cable Organizer for Wall Mounting
Purposes only. This cable organizer is not utilized on the Pedestal Mounting System.
•
One (1) ClipperCreek HCS EVSE Pedestal Kit, ClipperCreek part number 0300-00-019.
•
One (1) ClipperCreek HCS Charging Station (EVSE), part number depends on amperage selected.
•
One (1) ClipperCreek Dual-Mount TESLA® Mounting Plate Kit, ClipperCreek part number 0300-00-021.
•
Two (2) dedicated 208 or 240 VAC branch circuits.
•
Two (2) circuit breakers, appropriately sized with respect to the charging capacity of each EVSE.
•
Two pairs (2x2) Live Line conductors (one pair for each EVSE) with enough length to comfortably pull all the way through and
above the top of the pedestal.
•
Two (2) Ground Line conductors (One for each EVSE) or a single bonded Ground Line with enough length to comfortably pull all
the way through and above the top of the pedestal.
•
Conduit sized to fit all Live Line and Ground Line conductors.