32
Copyright Enphase Energy Inc. 2010
141-00010 Rev 01
Chirp set
Press this icon to turn the audible chirp sound on or off.
F/C Set
Press this icon to toggle the temperature display scale between °F and
°C.
Humidity
The Environ has a humidistat to control an external
humidifier for humidifying by the H terminal.
HUMIDIFIER
: To set a minimum
humidity level with a humidifier
installed in the HVAC:
1.
From the
HOME
screen, press
MENU
, then press
HUMIDITY
.
2.
Toggle
HUMIDIFR
from
<OFF>
to
<W/HEAT>
.
3.
Press
MIN --%
and use the
+
/
-
buttons to set the desired
minimum humidity level.
4.
The Environ can be toggled
<ALWAYS>
run the humidifier
when the humidistat calls for humidity (fan also runs) or can be
set to run only when the humidistat is calling for humidity and
the heat is also running
<W/ HEAT>
.
DE-HUMID BY A/C
: The Environ’s humidistat can also control the Air
Conditioner for dehumidifying. To set a maximum humidity level (using
the air conditioner):
1.
Press
MENU
, then press the
HUMIDITY
, then view
DE-HUMID
by A/C.
2.
Press
MAX --%
and use the
+
/
-
buttons to set the desired
maximum humidity level.
Note:
You cannot change MAX humid
% until you set it
to
ALWAYS
or
HST+TST
.
3.
The Environ can be toggled to
<ALWAYS>
run the air
conditioner when the humidistat calls to dehumidify or can be
set to run the air conditioner only when the humidistat calls to