IQ 6 / IQ 6+ Micro Installation and Operation
© 2017 Enphase Energy Inc. All rights reserved.
141-00034-01
39
IQ6PLUS-72-2-US
Microinverter Parameters
Miscellaneous Parameters
Maximum microinverters per 20 amp (max) AC
branch circuit
240 VAC (single phase)
208 VAC (single phase)
13
11
CEC weighted efficiency
240 VAC (single phase)
208 VAC (single phase)
%
97.0
96.5
Static MPPT efficiency (weighted, ref EN 50530)
%
99.5
Total harmonic distortion
%
5
Ambient temperature range
C
-40
+65
Night tare loss
mW
50
Storage temperature range
C
-40
+85
Features and Specifications
Compatibility
Pairs with most 60 and 72-cell PV modules
Dimensions not including mounting bracket
219 mm x 191 mm x 37.9 mm (approximate)
Connector type
MC-4 locking type
Weight
1.5 kg (3 lbs.)
Environmental category / UV exposure rating
Outdoor NEMA 250, type 6 (IP67)
Torque specifications for fasteners
(Do not over torque)
•
6 mm (1/4”) mounting hardware: 5 N m (45 to 50
in-lbs.)
•
8 mm (5/16”) mounting hardware: 9 N m (80 to
85 in-lbs.)
•
When using UL 2703 mounting hardware, use
the manufacturer’s recommended torque value
Cooling
Natural convection - no fans
Relative humidity range
4% to 100% condensing
Approved for wet locations
Yes
Pollution degree
PD3
Communication
Power line
Standard warranty term
enphase.com/warranty
Compliance
UL62109, UL1741/IEEE1547, FCC Part 15 Class B,
ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01
This product is UL Listed as PV Rapid Shut Down
Equipment and conforms with NEC-2014 and NEC-2017
section 690.12 and C22.1-2015 Rule 64-218 Rapid
Shutdown of PV Systems, for AC and DC conductors,
when installed according manufacturer’s instructions.
Grounding
The DC circuit meets the requirements for ungrounded
PV arrays in NEC. Ground fault protection (GFP) is
integrated into the class II double insulated microinverter.
Monitoring
Enlighten Manager and MyEnlighten monitoring options
require an Enphase IQ Envoy
Integrated DC disconnect
The DC connector has been evaluated and approved for
use as the load-break disconnect required by NEC 690.
Integrated AC disconnect
The AC connector has been evaluated and approved for
use as the load-break disconnect required by NEC 690.