background image

Enphase Customer Support:

 

enphase.com/en-us/support/contact

FCC Statement

: This equipment has been tested and found to comply 

with the limits for a Class B digital device, pursuant to part 15 of the 

FCC Rules. These limits are designed to provide reasonable protection 

against harmful interference in a residential installation. This equip-

ment generates, uses and can radiate radio frequency energy and, if 

not installed and used in accordance with the instructions, may cause 

harmful interference to radio communications. However, there is no 

guarantee that interference will not occur in a particular installation. If 

this equipment does cause harmful interference to radio or television 

reception, which can be determined by turning the equipment off and on, 

you are encouraged to try to correct the interference by one or more of 

the following measures:

  - Reorient or relocate the receiving antenna.

  - Increase the separation between the equipment and the receiver.

  - Connect the equipment into an outlet on a circuit different from that  

     to which the receiver is connected.

  - Consult the dealer or an experienced radio/TV technician for help.

Changes or modifications not expressly approved by the party re

-

sponsible for compliance may void the user’s authority to operate the 

equipment.
This Class B digital apparatus complies with Industry Canada ICES-003.

SAFETY

Safety and Advisory Symbols

+

DANGER

: This indicates a hazardous situation, which if not 

avoided, will result in death or serious injury.

*

WARNING

: This indicates a situation where failure to follow 

instructions may be a safety hazard or cause equipment 

malfunction. Use extreme caution and follow instructions 

carefully.

NOTE

: This indicates information particularly important for 

optimal system operation. Follow instructions carefully.

Safety Instructions

+

DANGER

: Risk of electric shock. Risk of fire. Do not attempt 

to repair the IQ8D Commercial Gateway; it contains no 

user-serviceable parts. Tampering with or opening the IQ8D 

Commercial Gateway will void the warranty. Warranty void 

if cover removed. If the IQ8D Commercial Gateway fails, 

contact Enphase Customer Support for assistance (

enphase.

com/en-us/support/

). 

+

DANGER

: Risk of electric shock. Always open or disconnect 

circuit from power-distribution system (or service) of building 

before installing or servicing current transformers (CTs).

+

DANGER

: Risk of electrocution! Do not install CTs when cur-

rent flowing in the sensed circuit. Always install CT wires in 

the terminal blocks before energizing the sensed circuit.

+

DANGER

: Risk of electric shock. Do not use Enphase equip-

ment in a manner not specified by the manufacturer. Doing so 

may cause death or injury to persons, or damage to equip-

ment. 

+

DANGER

: Risk of electric shock.  Be aware that installation of 

this equipment includes risk of electric shock. Always de-en-

ergize the load center before beginning wiring.

+

DANGER

: Risk of electric shock. Risk of fire. Only qualified 

personnel should troubleshoot, install, or replace the IQ8D 

Commercial Gateway.

+

DANGER

: Risk of electric shock. Risk of fire. Do not wire 

unused terminals or terminal blocks on the IQ8D Commercial 

Gateway.

*

WARNING

: Before installing or using the IQ8D Commercial 

Gateway, read all instructions and cautionary markings in the 

technical description and on the IQ8D Commercial Gateway.

*

WARNING

: Risk of equipment damage. If installing the 

IQ8D Commercial Gateway in an enclosure, choose area for 

installation where ambient temperature does not exceed 46º 

C (115º F).  

NOTE

: Do not install the CTs in a panel where they exceed 

75% of the wiring space of any cross-sectional area within the 

panel, or refer to local standards for guidance.

NOTE

Do not install CTs in an area where they will block 

ventilation openings, or in area of breaker arc venting.

NOTE

:

 The CTs are not suitable for Class 2 wiring methods 

and not intended for connection to Class 2 equipment.

NOTE

Secure CT and route conductors so that they do not 

directly contact live terminals or bus.

NOTE

: Perform all electrical installations in accordance with 

all national and local electrical codes.

NOTE

: To ensure optimal reliability and to meet warranty 

requirements, the Enphase IQ8D Commercial Gateway must 

be installed according to the instructions in this guide.

© 2022 Enphase Energy. All rights reserved. Enphase, the Enphase 

logo, Enphase IQ Series, Enphase Installer App, Enphase IQ8D Com-

mercial Gateway, Enphase IQ8D Microinverter, and other trademarks or 

service names are the trademarks of Enphase Energy, Inc. Data subject 

to change. Rev03-05-25-2022

Summary of Contents for IQ8D

Page 1: ... bridge with Ethernet cables order EPLC 01 You must use a ferrite bead on the Ethernet cable we recommend Fair Rite 0431167281 Ethernet cable 802 3 Cat5E or Cat6 unshielded twisted pair UTP Do not use shielded twisted pair STP cable You must use a ferrite bead on the Ethernet cable we recommend Fair Rite 0431167281 H Create a paper installation map to record device serial numbers and positions in ...

Page 2: ...ion on Line 1 Connect the white wire to the white C1 and the blue wire to the blue C1 terminal Clamp the CT on the main supply Line 1 When the consumption CT is on Line 1 conductor the arrow must point toward the load away from the grid To monitor consumption on Line 2 Connect the white wire to the white C2 terminal and the blue wire to the blue C2 terminal Clamp the CT on the main supply Line 2 W...

Page 3: ...e arrows must point toward the load away from the grid L2 Red L3 Blue N White L1 White L1 Blue L3 White L3 Blue L2 White L2 Blue L2 White L2 Blue L3 White L3 Blue L1 White L1 Black Production Consumption P1 C1 C2 1 2 3 4 NO Ref Common C Digital Input Relay PD B300 OVC II L1 L2 N CU 75C 14AWG MIN MEAS CAT III OVC III Production Consumption L3 P2 P3 C3 U80002 YYWW FALCO POLLUTION DEGREE 3 L1 Blue IQ...

Page 4: ... check the Overview screen for the following A Confirm that the expected number of devices are detected and com municating B Check that the new profile is set on all the devices Setting the profile may take up to 5 minutes for a typical system C Tap the Meters button D Tap Production Meter and follow the on screen instructions to enable the Production Meter E If you installed consumption metering ...

Page 5: ...tem name from the Activa tion List on the dashboard D From the activation form open Array Builder If you used Enphase Installer App to build arrays and scan device serial numbers the array s are built make any necessary adjustments in Array Builder If you did NOT use Enphase Installer App to build arrays and scan device serial numbers create the virtual array in Array Builder using the installa ti...

Page 6: ...pport DANGER Risk of electric shock Always open or disconnect circuit from power distribution system or service of building before installing or servicing current transformers CTs DANGER Risk of electrocution Do not install CTs when cur rent flowing in the sensed circuit Always install CT wires in the terminal blocks before energizing the sensed circuit DANGER Risk of electric shock Do not use Enp...