Enphase Customer Support:

 http://enphase.com/global/contact

 - 

F I E L D   W I R E A B L E   Q   C O N N E C T O R S   -   T H R E E - P H A S E

Safety Symbols

+

DANGER

: This indicates a hazardous situation, which if 

not avoided, will result in death or serious injury.

*

WARNING

: This indicates a situation where failure to 

follow instructions may be a safety hazard or cause 

equipment malfunction. Use extreme caution and follow 

instructions carefully.

;

WARNING

: Risk of burn. Failure to follow instructions may 

result in burn injury.

NOTE

: This indicates information particularly important 

for optimal system operation.

SAFETY

IMPORTANT SAFETY INSTRUCTIONS.  

SAVE THIS INFORMATION.

 

Follow all safety and assembly instructions when installing En-

phase Field Wireable Q Connectors. 

Safety Instructions

+

DANGER

: Risk of electric shock. Do not use Enphase 

equipment in a manner not specified by the manufacturer. 

Doing so may cause death or injury to persons, or dam-

age to equipment.

+

DANGER

: Risk of electric shock. Be aware that installation 

of this equipment includes risk of electric shock. Do not 

use without first removing AC power from the Enphase 

System. Disconnect the power coming from the photovol-

taics before servicing or installing.

+

DANGER

: Risk of electric shock. Risk of fire. Before mak

-

ing any connections verify that the circuit breakers are in 

the off position. Double check all wiring before applying 

power.

+

DANGER

: Risk of electric shock. Risk of fire. Only use 

electrical system components approved for wet locations, 

including but not limited to conduit fittings.

+

DANGER

: Risk of electric shock. Risk of fire. Only qualified 

 

personnel should install, troubleshoot, or replace the 

Enphase Field Wireable Q Connector.

+

DANGER

: Risk of electric shock. Improper use of the Field  

Wireable Q Connector or its components may result in a 

shock, fire or explosion. To reduce these risks, disconnect 

all wiring before attempting any maintenance.

+

DANGER

: Risk of electric shock. Risk of fire. Ensure that all 

AC and DC wiring is correct and that none of the AC wires 

are pinched, shorted, or damaged.

+

DANGER

: Risk of electric shock. Risk of fire. Do not 

attempt to repair or alter the Enphase Field Wireable Q 

Connector. 

+

DANGER

: Risk of electric shock. Risk of fire. Make sure the 

 

conductors are not damaged. If the exposed wires are  

damaged, the system may not function properly.

*

WARNING

: Risk of equipment damage. Enphase male and  

female connectors must only be mated with the matching  

male/female connector.

*

WARNING

: Risk of equipment damage. This product is 

intended for operation with a maximum operating temper-

ature of 110ºC.

*

WARNING

: When installing the cabling, secure any loose 

cable to minimize tripping hazard.

*

WARNING

: Before installing or using the Enphase Field 

Wireable Q Connector, read all instructions and cautionary 

markings in the technical description, on the Enphase 

System, and on the photovoltaic (PV) equipment.

*

WARNING

: Never plug in or disconnect the connectors 

under load. The connectors are not suitable for interrupt-

ing the current.

*

WARNING

: Without earthing connection.

NOTE

: Using unapproved attachments or accessories 

may result in damage or injury.

NOTE

: When looping the Enphase Q Cable, do not form 

loops smaller than 12 cm in diameter.

NOTE

: Perform all electrical installations in accordance 

with all applicable local electrical codes.

NOTE

: To ensure optimal reliability and to meet warranty 

requirements, install the Enphase Field Wireable Q Con-

nectors according to the instructions in this guide.

NOTE

: Protection against lightning and resulting voltage 

surge must be in accordance with local standards. 

NOTE

: The connector is considered to be in compliance 

only when assembled in the manner specified by these 

assembly instructions.

NOTE

: For flexible wires, we recommend using ferrules 

acc. to DIN 46228 that are crimped with jointing clamp.

NOTE

: Cable used with Enphase Field Wireable Q Connec-

tors must meet the following requirements:

• Min/max outer insulation diameter (including the  

   clear second insulator): 8mm / 21mm

• Wire size: 2.5mm2  to 6mm2

DISCONNECT (if needed)

To disconnect Enphase three-phase Field Wireable Q Connectors, 

release the two connectors by pressing down the snap with a screw-

driver. You can then separate the connectors.

*  

WARNING: Never plug in or disconnect the connectors under 

load. The connectors are not suitable for interrupting the current.

Enphase Article Number Enphase Product SKU Type  Designation

150-00094

Q-CONN-3P-10F

PRC 5-FC-FS6...

150-00093

Q-CONN-3P-10M

PRC 5-FC-MS6...