Installation with accessories of “Stack” types:   

Please install the types of units according to the following illustration. 
 
 

S t a c k   i n s t a l l a t i o n  

 

 

 

 

Summary of Contents for Evo UPS 1000VA

Page 1: ...1 U P S 1000VA 3000VA USER S MANUAL 2011 11 v 1 0 ...

Page 2: ...lace the receiving antenna in a separate location or orientation Ensure a greater distance is achieved between the receiver and the equipment Ensure that your equipment is connected to an outlet on a separate circuit than the receiver Contact a technician experienced with radio and TV or a dealer for further assistance ICES 003 This Class B Interference Causing Equipment meets all requirements of ...

Page 3: ...ts 1000 3000 VA 25 7 User s guide to operations 26 7 1 Starting and shutting down the UPS 26 7 2 Button Operation 26 7 3 Control Panel functions 27 7 4 Interpreting UPS messages 31 7 5 Trouble shooting 32 8 Maintenance 33 9 Technical Specifications 34 9 1 1Power Range 1000 3000 VA at P F 0 8 LV Tower and 19 RM model 34 9 1 2 Power Range 1000 3000 VA at P F0 9 LV Tower and 19 RM model 34 9 2 1 Powe...

Page 4: ...ectric shock do not remove cover No user serviceable parts inside Refer servicing to qualified service personnel CAUTION Non isolated Battery supply Risk of electric shock battery circuit is not isolated from AC input hazardous voltage may exist between battery terminals and ground Test before touching WARNING Fuses To reduce the risk of fire replace only with the same type and rating of fuse CAUT...

Page 5: ... risk of electric shock disconnect the UPS from the mains supply before installing a computer interface signal cable Reconnect the powers cord only after signaling interconnections have been made Servicing of batteries should be performed or supervised by personnel knowledge of batteries and the required precautions Keep unauthorized personnel away from batteries CAUTION When replacing batteries r...

Page 6: ...NSI NFPA 70 CAUTION FOR 1000 2000VA with I P Terminal Block Only To reduce the risk of fire Connect only to a circuit provided with 20 amperes maximum branch circuit overcurrent protection in accordance with the National Electric Code ANSI NFPA 70 ...

Page 7: ... on this equipment must be carried out by qualified service personnel Before conducting any maintenance repair or shipment first ensure that everything is turned off completely and disconnected For additional safety instructions please use the Safety Manual as reference Special Symbols The following symbols used on the UPS warn you of precautions RISK OF ELECTRIC SHOCK Please observe the warning t...

Page 8: ...her critical instrumentation etc The purpose of the UPS is to protect these systems from poor quality utility power complete loss of power or other associated problems Electrical interference abounds in many forms causing problems in AC power from lightning power company accidents and radio transmissions to motors air conditioners and vending machines among others So protection of sensitive electr...

Page 9: ...e converter increases voltage appropriately for the inverter Fig 1 Block diagram Efficiency Optimizer function The Efficiency Optimizer function is a new feature for the UPS adding cost effectiveness minimizing power loss and reducing power consumption Alternating between bypass and on line modes is achieved automatically and in accordance with the conditions of the utility power On line mode may ...

Page 10: ...ormal mode operation a battery discharge test is performed and any problems reported on the LCD display Except during the first 24 hours after startup while the UPS is in charging mode please see chapter 7 2 diagnostic tests can be performed manually from the front panel at any time 2 2 System Configuration The UPS device and the internal backup battery make up the system Depending on the site and...

Page 11: ...ailable Model Backup time Internal batteries Recharge time to 90 capacity UPS 1000VA 3 5 min 4 hours UPS 2000VA 3 5 min 4 hours UPS 3000VA 3 4 min 4 hours Additional External Battery Cabinets are available if more back up time is needed ...

Page 12: ...al hazards may be fatal so keep this manual for all future reference WARNING It is strongly advisable not to open the UPS cabinet as the components have very high voltage and touching them may be fatal Only a technician from the manufacturer or an authorized agent may service the unit This UPS unit s output receptacles carry live voltage even when not connected to a power supply as it has its own ...

Page 13: ...nd requirements are met according to these technical specifications otherwise the safety of installation personnel cannot be guaranteed and the unit may malfunction Ensure that you remember the following when locating the UPS system and battery options Avoid extremes of temperature and humidity Maximal battery life can be attained with a recommended temperature range of 15 C to 25 C Provide protec...

Page 14: ...sories of Rack mounted types Please install the vertical and wall mounted types of units according to the following illustration Vertical Installation Wall mounted installation Installation with accessories of Rack mounted types ...

Page 15: ...e install the types of units according to the following illustration Installation with bottom bracket Part No RMB 06 2 PCS Screw M5 11 4 PCS Installation with rear bracket Part No RMB 01 2PCS Screw M5 11 4 PCS ...

Page 16: ...16 Installation with accessories of Stack types Please install the types of units according to the following illustration Stack installation ...

Page 17: ...17 5 2 Rear panel view 1KVA REAR PANEL ...

Page 18: ...18 2K 3KVA REAR PANEL ...

Page 19: ...19 RM 2U 1KVA Rear Panel ...

Page 20: ...20 RM 2U 2K 3KVA Rear Panel ...

Page 21: ...ter 7 2 Connect the Input cable to the UPS and connect the other end to a grounded outlet The batteries will automatically charge when connected to the mains Please realize that although you may start using the UPS immediately maximum back up time will still not be available so it is recommended to charge the batteries for a minimum of 8 hours before use If unit instantly shows a Site Wiring Fault...

Page 22: ...FOR HV series Input Bypass Voltage 10 10 15 15 20 10 15 Input Frequency 2 5 7 5 HE Mode Setting On Off Off Free Run Mode On Off On Bypass Enable Disable at free run mode Disable Enable Disable Alarm silence On Off Off Site wiring alarm Enable Disable Disable External Battery pack setting 0 1 2 0 You may change default settings but we recommend that this is done after installation and before starti...

Page 23: ... local dealer will have more information about these option cards Connecting the UPS to a Computer The communication device for the UPS and PC comes as a complete package with power management software Only the communication cable provided with UPS may be used to connect to your computer which is accomplished through the UPS RS232 port Also ensure that the operating system on your computer is supp...

Page 24: ...24 6 Output Ac Fail Output 8 Output Low Battery Output 9 Output 12 VDC Power Caution Max rated values 12Vdc ...

Page 25: ...egain power to the outlets Network Transient protector 1000 3000 VA The network transient protector located on the back panel has both IN and OUT jacks and houses a single RJ 45 10BaseT network connector Connect the input connector to the jack labeled IN and the output connector to the jack labeled OUT 6 2 Load segments 1000 3000 VA The power management software controls the sets of receptacles kn...

Page 26: ...he outlets During this inspection the LCD will display Ready on The LED shall light up when output power has commenced and the LCD will display Line mode Switch on the loads Shutting down the UPS Shut down and turn off the loads Push the button on the front panel for five seconds The alarm will sound and the UPS will shut down The LCD will display UPS OFF for a few seconds In emergency situations ...

Page 27: ...ush the button to confirm and enable your function f If no pressing within 10 seconds it will return to original status 7 3 Control Panel functions Operation of the UPS is indicated on the monitor panel with five LED indicators and an LCD screen This display is also capable of alerting the user with audible alarms ON This green LED is lit when UPS has been turned on ON LINE When the UPS is in norm...

Page 28: ...s display Various measurements are available through the UPS meters display pressing the button will scroll through the following meters LCD message Description O P VOLT xxx xV Shows Output AC voltage O P FREQ xx x Hz Shows Output Frequency I P VOL T xxx xV Shows Input AC voltage I P FREQ xx x Hz Shows Input Frequency BAT VOLT xx xV Shows Battery Voltage O P LOAD xx Shows Load of max load O P W xW...

Page 29: ...save your selection Other options are saved and started automatically See the table below for further details If no buttons are pressed or user inactivity for ten seconds the UPS shall exit the configuration mode and return to normal mode displaying Line mode Caution The factory default settings do not necessarily have to be changed although you are free to tailor the UPS to your specific needs Se...

Page 30: ...Silence Function Silence Set Enable or disable silence function ON OFF OFF Number of External battery Packs Bat Cabinet Set This setting is needed For UPS to predict Backup time 0 only internal batteries 1 one external cabinet 2 two external 0 Site wiring alarm Sit Fault Set You can enable or disable the site wiring alarm Enable Disable Disable Select Language Language Select load language English...

Page 31: ...Troubleshooting procedures described here give simple instructions in determining UPS malfunctions Start the troubleshooting procedure if you witness any alarm indication on the control panel Alarm indicators The UPS gives the following audible alarms If UPS is on battery and the ON BATTERY LED is on UPS will beep every 5 seconds If the battery capacity is low and the ON BATTERY LED is flashing th...

Page 32: ... 5 seconds The unit is operating on Battery Power Save your data and perform a controlled shutdown Charger Failure Constant beep Charger has failed Phone the local dealer Over Temperature Constant beep High ambient Temperature Make sure the unit s fans and vent holes are not blocked and make sure the ambient surrounding temperature is not above 40 degree C If these conditions did not solve the pro...

Page 33: ...f 6 to 12 months whether the back up time of the battery is adequate for its WARNING Batteries may cause electrical shock or burn from high short circuit currents Please observe the following precautions 1 Remove jewelry and metal objects such as watches and rings 2 Use tools that have insulated handles 3 Keep tools and other metal objects from contacting and away from the batteries ELECTRIC ENERG...

Page 34: ... 0 97 OUTPUT Output Voltage 100 110 115 120 127 VAC selectable from LCD panel Voltage regulation 2 Voltage distortion 5 THD at full non linear load 2 THD at full linear load Frequency regulation 0 25 Hz battery or free running mode Dynamic response 9 max from 100 to 20 or from 20 to 100 linear load Overload capacity 106 120 30 sec 121 150 10 sec Efficiency about 89 9 1 2 Power Range 1000 3000 VA a...

Page 35: ... by external batteries output toward loads must be limited to less than 90 of overall power generation 9 2 1 Power Range 1000 3000 VA at P F 0 8 HV Tower and 19 RM model GENERAL Rated power 1000 VA 2000 VA 3000 VA at P F 0 8 Technology On line double conversion topology with automatic bypass INPUT Phase Single phase with ground Bypass Voltage 184 265 VAC user selectable Input Voltage range 120 140...

Page 36: ...tage range 120 140 160 180 VAC 276 VAC 120V at 25 load 140V at 50 160V at 75 180V at 100 Frequency 50 60 Hz Auto selection Frequency window from mains 45 65 Hz Synchronization window 2 5Hz Input current 1000 VA 4 3A 2000 VA 8 7A 3000 VA 13A Input Power factor 0 97 OUTPUT Output Voltage 208 220 230 240 VAC selectable from LCD panel Voltage regulation 2 Voltage distortion 5 THD at full non linear lo...

Page 37: ...00VA EN62040 2 Category C2 2000 3000VA HV Tower Model at P F 0 8 OUTPUT POWER 1000VA 800W 2000VA 1600W 3000VA 2400W Connection Input IEC 320 10A IEC 320 10A IEC 320 16A Connection Output 4 x IEC 320 10A 8 x IEC 320 10A 1 x IEC 320 16A 8 x IEC 320 10A 1 x IEC 320 16A 4 x 5 15R US 12 x 5 15R US 12 x 5 15R US 2 x Europe 6 x Europe 1 x IEC 320 16A 6 x Europe 1 x IEC 320 16A Battery type Lead acid 7AH ...

Page 38: ... 4 hours to 90 Dimensions W x D x H mm 152 x 420 x 238 225 x 420 x 358 225 x 420 x 358 Net Weight kg 16 2 31 1 33 6 HV 19 Rack mount Model at P F 0 8 2U OUTPUT POWER 1000VA 800W 2000VA 1600W 3000VA 2400W Connection Input IEC 320 10A IEC 320 10A IEC 320 16A Connection Output 4 x IEC 320 10A 4 x IEC 320 10A 1 x IEC 320 16A 4 x IEC 320 10A 1 x IEC 320 16A 4 x 5 15R US 4 x 5 15R US 4 x 5 15R US 2 x Eu...

Page 39: ...5 min 2 5 3 5 min Recharge time 4 hours to 90 4 hours to 90 4 hours to 90 Dimensions W x D x H mm 428 x 425 x 84 428 x 635 x 84 428 x 635 x 84 Net Weight kg 17 1 31 6 32 5 LV Tower Model ay P F 0 8 OUTPUT POWER 1000VA 800W 2000VA 1600W 3000VA 2400W Connection Input Attached power cord Connection Output 6 x 5 15R US 12 x 5 15R US 12 x 5 15R US Battery type Lead acid 7AH 12V Lead acid 7AH 12V Lead a...

Page 40: ...imensions W x D x H mm 152 x 420 x 238 225 x 420 x 358 225 x 420 x 358 Net Weight kg 16 2 31 1 33 6 LV 19 Rack mount Model at P F 0 8 2U OUTPUT POWER 1000VA 800W 2000VA 1600W 3000VA 2400W Connection Input Attached power cord Connection Output 6 x 5 15R US 4 x 5 15R US 4 x 5 15R US Battery type Lead acid 7AH 12V Lead acid 7AH 12V Lead acid 5AH 12V Number of batteries 3 6 8 Backup time full load 3 5...

Page 41: ...imensions W x D x H mm 428 x 425 x 84 428 x 635 x 84 428 x 635 x 84 Net Weight kg 17 1 31 6 32 5 Battery Cabinets 1000 VA 2000 VA 3000 VA Battery type Lead acid 7 AH 12 V Lead acid 7 AH 12 V Lead acid 5 AH 12 V Number of batteries 6 12 16 Backup time full load Approx 13 15 min battery pack only Approx 13 15 min battery pack only Approx 10 13 min battery pack only Recharge time 8 h to 90 8 h to 90 ...

Page 42: ... to connect and use No 10 AWG 90 C copper wire and 20 lb in torque force when connecting CAUTION To reduce the risk of fire connect only to a circuit provided with 30 amperes maximum branch circuit overcurrent protection in accordance with the National Electrical Code ANSI NFPA 70 ...

Page 43: ...ton to select the option On 8 You may be prompted to save the selection if so press the button to either confirm or save your selection Other options are saved and started automatically See the table below for further details 9 If no buttons are pressed or user inactivity for ten seconds the UPS shall exit the configuration mode and return to normal mode displaying Line mode 10 After switching to ...

Page 44: ...er 6 You will see Manual Bypass is On 7 Press the button to scroll through the options for Manual Bypass till you see option Off 8 Press the button to select the option Off You may be prompted to save the selection if so press the button to either confirm or save your selection Other options are saved and started automatically See the table below for further details 9 If no buttons are pressed or ...