Heart rate 

Set a certain heart rate target, based on patient 
data and the purpose of the training (e.g. warming 
up, endurance training, etc.). The device will help 
you set the applicable target heart rate by means of 
several training zones. 
When selecting heart rate as the training goal, the 
training zones are displayed: 

 

  Before starting any training or test, please 

make sure the patient is screened 
thoroughly and you are sure there will be no 
adverse effects for the health of your 
patient. 
 

 

 

To define the right heart rate for the selected 
training zone, we need to know the maximum heart 
rate. 
 
First select male or female. 
 

 

 
 
 
 
 
 
 

Summary of Contents for 1413921

Page 1: ...EN109 1413760 47 IFU BIKE REHA Instructions for Use Part number EN109 1413760 47 IFU January 4 2021 ...

Page 2: ...09 1413760 47 IFU TABLE OF CONTENTS 1 INTRODUCTION 3 2 SYMBOLS 4 3 PACKAGE CONTENTS 5 4 SETUP 6 5 USING THE DEVICE 7 6 OPERATION 12 7 MAINTENANCE 25 8 ORDERING INFORMATION 26 9 SPECIFICATIONS 27 10 PRODUCT LIABILITY 28 ...

Page 3: ...Reha This bicycle ergometer is intended for stationary cycling and to help you treat patients in the field of physical medicine and rehabilitation We hope that this will be a valuable device in the execution of your profession and that it will improve the health and quality of life of many people ...

Page 4: ... and contact information of the manufacturer and production date Reference or model number Serial number used for identification of the device Indicates that the item is a medical device Indicates a carrier that contains Unique Device Identifier information Indicates Type B applied parts No electrical contact with Patient and may be earthed Indicates the range of atmospheric pressure to which the ...

Page 5: ...ustable cranks art nr 1413922 you will find enclosed 1x 1413768 Instructions for Use PDF on CD 1x 1413764 Information Booklet 1x 3444298 Power cord Alternating current Emergency stop button Use of accessories and cables other than those specified or provided by the manufacturer of this equipment is NOT allowed ...

Page 6: ... of the frame After the mains cable has been connected switch on the device by using the switch located next to the mains cable connection The Bike Reha is now ready for use In case of damage contact your local distributor Do NOT use the device To avoid the risk of electric shock this equipment must only be connected to a mains supply with protective earth No unauthorized modification of this equi...

Page 7: ...ns the devices can and can not be used Following the ACSM recommendations for preparticipation health screening the professional user should screen every patient by a self reported medical history or health risk appraisal questionnaire The need and degree of follow up is determined by the answers to these self guided methods Patients diagnosed with the following disease should consult with their p...

Page 8: ...ors from the list below should be encouraged to consult with their physician prior to initiating a vigorous intensity physical activity program These risk factors include You are a man 45 yr You are a woman 55 yr You smoke or quit smoking within the previous 6 months Your blood pressure is 140 90 mm Hg You do not know your blood pressure You take blood pressure medication Your blood cholesterol le...

Page 9: ...enotic valvular heart disease Electrolyte abnormalities e g hypokalemia or hypomagnesemia Severe arterial hypertension i e systolic blood pressure SBP of 200 mm Hg and or a diastolic BP DBP of 110 mm Hg at rest Tachydysrhythmia or brady dysrhythmia Hypertrophic cardiomyopathy and other forms of outflow tract obstruction Neuromotor musculoskeletal or rheumatoid disorders that are exacerbated by exe...

Page 10: ...essary A single turn is sufficient Then pull the button to release the seat post Support the saddle with your hand and never do this while someone is sitting on the saddle Release the button when the saddle is at the desired height Move the seat post slightly up or down to release the button The red button will then no longer protrude The knob can subsequently be tightened again in the indicated d...

Page 11: ...r test please make sure the patient is screened thoroughly and you are sure there will be no adverse effects for the health of your patient Always provide the patient with clear information about the training or test State the purpose of the training or test what is going to happen and what is expected of the person concerned When you want the patient to operate the device under your supervision a...

Page 12: ...djust another parameter touch the screen to activate that parameter If no arc appears above this parameter it means it cannot be adjusted HOME MENU After switching on the device a welcome screen will be displayed while the device performs a self test At the end of the self test the unit enters the Home Menu and is ready for use Before starting any training or test please make sure the patient is s...

Page 13: ...t rate The arc above the displayed level indicates that the rotary knob can be used to adjust the level By default the elapsed time will be displayed When pressing the show more tab on the right side more parameters will appear The screen will show Elapsed time min sec Speed km h Cadence rpm Distance covered km Heart rate bpm when the chest belt is used Energy used kJ The training will start autom...

Page 14: ...l be kept at the selected level independent of the cadence Please note The slower the cadence rpm the higher the force for each rotation will be Torque Choose training on torque when you want to control the amount of force on the pedals The advantage of this training method is that when due to fatigue the cadence drops the amount of force required to ped will not increase This can be very convenie...

Page 15: ...the rotary knob Select the max heart rate to set this value in the same way HILL PROFILES This menu includes 12 set training programs Profiles 1 6 are displayed Use the rotary knob to go to page 2 profile 7 12 The power you need to set is the maximum power for this program Depending on the profile the power will vary between 50 and 100 of this value Apart from the profile and its maximum power you...

Page 16: ...ent data and the purpose of the training e g warming up endurance training etc The device will help you set the applicable target heart rate by means of several training zones Time Choose Time if the goal is to for instance train for 10 minutes Use the rotary knob to set the time Select the mode of training by touching the applicable button on the right and adjust to the desired value by using the...

Page 17: ... option if the goal is to cover a certain distance Again choose a training mode The intensity can be adjusted during training Energy Choose energy when your goal is to burn a specific amount of energy This might be relevant when weight control is important ...

Page 18: ...eart rate by means of several training zones When selecting heart rate as the training goal the training zones are displayed Before starting any training or test please make sure the patient is screened thoroughly and you are sure there will be no adverse effects for the health of your patient To define the right heart rate for the selected training zone we need to know the maximum heart rate Firs...

Page 19: ...isplay the target heart rate that was selected based on the training zone and patient s max heart rate TESTING The Bike Reha offers you various physical exercise tests With the exception of the Steep ramp test these tests require the use of a chest belt Like with the heart rate goal training the device will first ask you to enter the patient data When all personal data are entered a screen will gi...

Page 20: ...monitoring of the patient s progress The 3 minute test is a constant power protocol lasting 3 minutes The set value is calculated according to 1 Watt per kg body mass The power remains the same during the test and is followed after 3 minutes by a recovery phase 12 Minute test The 12 minute fitness test is a heart rate driven protocol meaning that the subjective exertion by the patient can be predi...

Page 21: ...abs is the estimated absolute value for the maximum oxygen uptake expressed in liters per minute Fitness level abs is a score based on the estimated absolute value for this maximum oxygen uptake This score can range from to to indicate the patients fitness compared to people of the same age and gender VO2max rel is the estimated relative value for the maximum oxygen uptake expressed in milliliters...

Page 22: ...55 9 20 29 33 0 33 0 36 4 36 5 42 4 42 5 46 4 46 5 52 4 52 4 30 39 31 5 31 5 35 4 35 5 40 9 41 0 44 9 45 0 49 4 49 4 40 49 30 2 30 2 33 5 33 6 38 9 39 0 43 7 43 8 48 0 48 0 50 59 26 1 26 1 30 9 31 0 35 7 35 8 40 9 41 0 45 3 45 3 60 20 5 20 5 26 0 26 1 32 2 32 3 36 4 36 5 44 2 44 2 3 min Test The heart rate achieved after 3 minutes is valued according to the table below Men fitness index Woman Fitn...

Page 23: ...t This is the so called Maximum Short Exercise Capacity MSEC Wmax endurance is the capacity that can be maintained for a longer period e g 3 minutes as during a maximum test The MSEC is used to estimate this maximum exertion capacity The Steep Ramp test provides an estimate of the absolute maximum oxygen uptake VO2 max abs and calculates a value related to bodyweight VO2max rel The fitness index i...

Page 24: ... more fun for patients to work out and therefor easier to spend a certain amount of time on the bike RPM Airlines Just set the goal time and the difficulty easy medium hard or expert level and start the game The game is a constant torque protocol and the challenge is to pedal at the right cadence to avoid hitting obstacles ...

Page 25: ...maged remove the power plug from the socket to prevent injury CLEANING Before performing any cleaning switch off the device and disconnect the plug from the mains supply Clean the device with a damp cloth using a household cleaner Do not spray the cleaning agent directly on the glass panel Do not use cleaning agents that contain strong alkalis lye acid detergents with fluoride or detergents with a...

Page 26: ...est belt for heart rate registration 3496838 Elastic strap for Sigma Sport chest belt for heart rate registration 1413760 Instructions for Use Bike Reha The latest version in electronic or printed format of this Instructions for Use can be obtained free of charge from our website http www enraf nonius com or by contacting distributor or by calling the telephone number 31 0 10 2030600 the Instructi...

Page 27: ...ht adjustable 75 115 cm Crank length 170 mm Adjustable cranks 80 180 mm Max patient weight 150 kg Heart rate registration possible with optional chest belt Exercise modes Levels Torque Power Heart rate Programs 12 pre programmed hill profiles Parameters Time Speed Cadence Distance Heart rate Energy ENVIRONMENTAL CONDITIONS Operating conditions Temperature 10 40 C Humidity 10 90 Air pressure 700 10...

Page 28: ... and productivity computer failure or malfunction or any and all other commercial damages or losses even if advised of the possibility thereof and regardless of the legal or equitable theory contract tort or otherwise upon which the claim is based In any case Enraf Nonius entire liability under any provision of this agreement shall not exceed in the aggregate the sum of the fees paid for this prod...

Page 29: ...Page 29 of 30 EN109 1413760 47 IFU ...

Page 30: ...Page 30 of 30 EN109 1413760 47 IFU Copyright Enraf Nonius B V Vareseweg 127 3047 AT Rotterdam The Netherlands Tel 31 0 10 20 30 600 Fax 31 0 10 20 30 699 info enraf nonius nl www enraf nonius com ...

Reviews: