TBE-160CM Instruction Manual
Oct 2013 (USA)
14
1. Ensure the power cord is connected to a suitable 110V AC
power outlet, and the red cable to the “Clean” socket.
2. Make sure the brush tip has its insulating shroud and the
insulation on the wand is undamaged.
3. Turn the On/Off switch to ON. The On/Off switch should
immediately be illuminated. If this does not occur, refer to
the “Troubleshooting” section.
4. Dip brush in cleaning fluid and apply brush tip to weld area
to be cleaned. Use only recommended cleaning fluids, see
S7.2.
5. Ensure brush and work area remain wet with fluid
during cleaning.
6. Apply brush only for as long as necessary to remove
discoloration. Prolonged application may affect
surface quality.
7. Some light sparking may occur where brush tip contacts
workpiece, this is normal. Excessive sparking for a
prolonged time in one area may cause surface pitting.
8. When desired surface finish is achieved, turn the On/Off
switch to OFF.
9. After use put the brush down on a non-flammable surface
as it may be very hot.
10. Be careful touching the work as it may be hot.
11. Rinse thoroughly with clean water to remove all traces of
cleaning fluid. To ensure acidic residue is removed, use the
recommended Ensitech neutralizing fluid, see S7.3.
S4 OPERATION
OPERATION (CLEANING)
4.4
1. Assemble marking head and felt, in accordance with
supplied instructions.
2. Ensure red cable is connected to the “Mark” socket.
3. Secure marking stencil on workpiece using adhesive tape.
4. Saturate marking felt with marking fluid and rub
the marking head firmly and steadily across stencil.
(Experiment on an offcut of similar metal to determine
optimum pressure and speed.)
OPERATION (MARKING)
4.5
Refer to illustrations on pages 13 and 15.