TBE-160CM Instruction Manual
Oct 2013 (USA)
18
S8 TROUBLESHOOTING
ON/OFF SWITCH NOT ILLUMINATED
ON/OFF SWITCH ILLUMINATED & UNIT NOT OPERATING
• Ensure the power switch is ON (with the “I” symbol on
the switch pressed in).
• Ensure the power cable is pushed completely into the
socket on the side of the TIG Brush.
• Ensure power is present at the power point (possibly by
plugging in another appliance, such as an
inspection light).
• Check the fuse located below the mains socket. Using a
small screwdriver, place the tip in the indentation under
the plastic fuse drawer and pull out the drawer. If the
fuse at the end of the drawer is broken replace with a
fuse of the same specification (8 amp slow blow fuse,
size M205).
• If the fuse blows again, contact your TIG Brush Supplier.
• Check the circuit breaker on the back of the unit. If a
current overload has occured the button will
be extended.
• Ensure that the brush and wand are not touching the
work piece.
• Switch the On/Off switch to OFF.
• Press the circuit breaker button in.
• Switch the TIG Brush unit ON and commence
working again.
8.1
8.2
If the TIG Brush is not operating correctly, please refer to the
following trouble shooting guide before contacting your TIG
Brush distributor.