background image

18

TBE-250 Instruction Manual

Feb 2012

S8 TROUBLESHOOTING

ON/OFF SWITCH NOT ILLUMINATED

ON/OFF SWITCH ILLUMINATED & FRONT 
PANEL POWER LIGHT NOT ILLUMINATED

• 

Ensure the power switch is ON (with the “I” symbol on 
the switch pressed in). 

• 

Ensure the power cable is pushed completely into the 
socket on the side of the TIG Brush. 

• 

Ensure power is present at the power point (possibly by 
plugging in another appliance, such as an 
inspection light).

• 

Check the fuse located below the mains socket. Using a 
small screwdriver, place the tip in the indentation under 
the plastic fuse drawer and pull out the drawer. If the 
fuse at the end of the drawer is broken replace with a 
fuse of the same specifi cation (8 amp, slow blow fuse, 
size M205). 

• 

If the fuse blows again, contact your TIG Brush Supplier.

• 

If the TIG Brush was being used prior to it turning off, 
and the heat-sink at the back of the unit feels hot 
(be careful as it may be very hot) the unit may have 
over-heated. Wait 30 minutes for the unit to cool down 
before trying to use it again. The unit can be cooled 
more quickly by placing a damp cloth on the heat-sink.

8.1

8.2

If the TIG Brush is not operating correctly, please refer to the 
following trouble shooting guide before contacting your TIG 
Brush distributor.

3

Ensitech Pty Ltd

www.ensitech.com.au

INDICATES AN IMMEDIATELY HAZARDOUS SITUATION. IF NOT 

AVOIDED, MAY RESULT IN MINOR OR MODERATE INJURY. IT 

MAY ALSO ALERT AGAINST UNSAFE PRACTICES. 

DANGER

THIS IS THE SAFETY ALERT SYMBOL. IT IS USED TO ALERT 

YOU TO THE POTENTIAL PERSONAL INJURY HAZARDS. OBEY 

ALL SAFETY MESSAGES THAT FOLLOW THIS SYMBOL TO 

AVOID POSSIBLE INJURY.

WARNING

SYMBOL FOR “VOID WARRANTY” OR “DAMAGED WORK” 

V

INDICATES AN IMMEDIATELY HAZARDOUS SITUATION. IF NOT 

AVOIDED, MAY RESULT IN MINOR OR MODERATE INJURY. IT 

MAY ALSO ALERT AGAINST UNSAFE PRACTICES. 

CAUTION

FOREWORD

THIS SYMBOL INDICATES AN IMMEDIATELY HAZARDOUS 

SITUATION WHICH SHOWS ENSITECH’S PROVISIONS FOR THE 

MILD ACID. IF PRECAUTIONS ARE NOT TAKEN, MAY RESULT 

IN MINOR OR MODERATE INJURY.

SAFETY ALERT SYMBOLS AND SAFETY SIGNAL WORDS

Summary of Contents for TIG Brush TBE-250

Page 1: ...Ltd in writing by sending a pre paid letter to Ensitech Pty Ltd PO Box 179 Springwood NSW 2777 Australia or email to info ensitech com au You must include your full name address and contact telephone...

Page 2: ...Ensure the clamp is gripping the work securely Sometimes the clamp position may need adjusting to make a good contact If dirt or debris has built up on the clamp clean it as this may prevent a good c...

Page 3: ...it may have over heated Wait 30 minutes for the unit to cool down before trying to use it again The unit can be cooled more quickly by placing a damp cloth on the heat sink 8 1 8 2 If the TIG Brush is...

Page 4: ...able from authorised TIG Brush distributors The insulating shroud may become damaged or heat affected Replacement shrouds are available A range of cleaning uids is available including TB 21ND Weld Cle...

Page 5: ...ning solution Allow to dry before re assembling Before assembling the brush to the wand coat threads with copper lled anti seize compound This will exclude the acidic solution from the joints and prev...

Page 6: ...y Ltd www ensitech com au S5 POWER AND GRADE SETTINGS MODE SETTINGS POWER CONTROL MODE CONTROL 5 2 POWER SETTINGS 5 1 Choose the cleaning intensity required by selecting the appropriate setting using...

Page 7: ...cessary to remove discolouration Prolonged application may affect surface quality 10 Some light sparking may occur where brush tip contacts workpiece particularly on higher power settings and this is...

Page 8: ...he TIG Brush for any purpose other than that described in this manual Failure to observe this warning may result in permanent damage to the TIG Brush cause damage to the workpiece cause injury to the...

Page 9: ...TIG Brush Unit 7 Attach clamp to workpiece 9 Ensitech Pty Ltd www ensitech com au S2 SAFETY PRECAUTIONS CAUTION Fluid spilled on the skin should be washed off as soon as practical Material Safety Data...

Page 10: ...6 7 8 3 1 2 3 4 5 6 7 8 TIG Brush Control Unit Clamp Cable Handle Cable Handle Wand Shroud Brush Power Cord 11 Ensitech Pty Ltd www ensitech com au TBE 250 TIG Brush S3 DESCRIPTION OF APPARATUS Power...

Reviews: