21
Installation instruction
for flat collectors on flat roof or foundation.
4.5 Determination of the minimal surface
Installation of the supporting constructions may take place only on a specially prepared
surface. In case of collector installation on a flat roof the minimal distance between the
collectors is 1m.
4.6 Number and spacing of the supporting triangles
Two supporting triangles are needed for the first collector. Each consecutive collector
should be provided with one supporting triangle more.
Spacing between the supporting triangles depends on the quantity of the installed collectors
and is respectively as follows:
Standard version
Light version
4.7 Number and configuration of multi-slot sections
The installation set includes an adequate number of multi-slot sections depending on the
quantity of collectors in a set.
Assembly triangles are provided with holes for installing the multi-slot sections.
Number of
collectors
Triangle
quantity
Triangle spacing [m]
Vertical
collector
2,0m
2
Vertical
collector
2,65m
2
Horizontal
collector
2,65m
2
1
2
0,806
0,920
1,956
2
3
0,956
1,070
2,233
3
4
1,006
1,120
2,325
4
5
1,031
1,145
2,371
5
6
1,046
1,160
2,399