29
Installation instruction
for flat collectors on flat roof or foundation.
6.5 Temperature sensor installation in clamping and o-ring connecting systems (except a hybrid
collector).
Installation damage
If the temperature sensor is incorrectly installed or the signal cable is damaged there is a
danger of installation damage.
- it is necessary to protect the signal cable from damage (damage by birds, rodents) e.g. by
using an electrical conduit.
The temperature sensor should be mounted in an
immersion sleeve,
- insert the temperature sensor as far as possible into the
immersion sleeve,
- secure the attached clamping spring from slipping.
6.6 Temperature sensor installation in a hybrid collector.
Installation instruction for temperature sensor
- the sensor should be placed in a specially placed sleeve, mounted under a Ø22mm pipe
(not in the transverse joint as in flat collectors),
- after placing the sensor in the sleeve (about 26cm) the sensor cable should be stabilized
with a bolt.
6.7 Connection of collecting pipes
Hydraulic connection with collecting pipes should be executed by the means of insulated
flexible cord.
Two rigid collecting pipes cannot be connected directly to a collector.
The connection of flexible cords with the system should be done below the level of the vent.
Note!
Use universal roof vents and aerial fittings to pass through the roof.
Note!
Along with the flexible return cord run a temperature sensor cable.