Installation instruction
for flat collectors on flat roof or foundation.
overpressure in the system p = 2,5 bar.
- Disconnect the filling station hoses from the drain valves (3 and 4).
7.3 Venting the solar system
After venting the system with the filling station and the manual vent it is necessary to close
the vent valve, in case of an automatic vent it is necessary to close the ball valve.
7.4 Insulation work
Insulation work should be done after performing all control activities.
Note!
- To insulate the wires outside of a building, use insulation resistant to weather conditions
and high temperature.
If necessary, protect the insulation against damage by birds.
- For insulation inside a building, use insulation resistant to high temperatures.
7.5 Masking profile installation – additional element *.
Masking profile installation instruction.
Masking profile (1) is installed between collectors
(2) by the means of three mounting elements (3).
By the means of mounting bolt (4) fix the mounting
elements (3) to the masking profile (1). Placing the
mounting elements: two pieces 20cm each from the
masking profile’s edge, third piece should be placed
in inside the masking profile.
Mounting elements (3) should be clutched and
successively placed in the top space between the
collectors (2).
Press the masking profile (1) evenly along its entire
length until the masking element’s (3) latch snaps in
the bottom pockets of collectors (2).
*A masking profile is not included in the basic set. It
can be ordered as an additional option
.