Installation instruction
of the flat solar collectors models ES1V2.0, ES1V2.65,
ES2V/2.0 AL, ES2V/2.65
integrated in the slate roof.
4.4.3 montage of the Cover flashing
4.4.4 montage of the cover flashing
Affix the cover flashings at the front side of both
collectors. The indication mark at the cover
flashing has to be positioned at the outer side of
each collector. Use the coloured and sealed self-
tapping screws (4,2 x 13mm) at the provided holes
in each cover flashing. The overhang on the outer
sides is 110mm.
Between the collectors the overlap of the cover
flashings should be 23mm.
Clip the centre flashing between both
collectors. Fix the centre flashing at the
provided holes with one screw in the
middle and two screws at the lower end
(coloured and sealed self-tapping screws
4,2 x 13mm).
Indication mark
Screws
110mm