Startup procedure for EnSy AHU units 

REV:0_08.09.2016.

 

KJK

 

We

 

reserve

 

the

 

right

 

to

 

change

 

technical

 

data

 

without

 

notice

     

http://www.ensy.no

 

Page 7 

 

8.

 

Checking

 

settings

 

for

 

the

 

fans

 

when

 

activating

 

cooker

 

hood

 

/

 

kitchen

 

ventilator.

 

 

To

 

get

 

balanced

 

ventilation

 

when

 

you

 

activate

 

the

 

cooker

 

hood

 

or

 

kitchen

 

ventilator

 

you

 

should

 

adjust

 

the

 

settings.

 

 

If

 

a

 

cooker

 

hood

 

is

 

used.

 

 

Press

 

control

 

button

 

4

 

once

 

to

 

get

 

into

 

4.

 

Preferences.

 

Press

 

control

 

button

 

3

 

three

 

times

 

to

 

get

 

to

 

Setup

 

menu.

 

 
 

Press

 

(Enter)

 

control

 

button

 

4

 

to

 

get

 

into

 

4.5

 

PIN

 

code

 

menu.

 

 
 
 
 

Press

 

control

 

button

 

3

 

(

+

)

 

once

 

and

 

you

 

will

 

have

 

1000

 

in

 

display.

 

 
 
 
 

Press

 

control

 

button

 

4

 

(enter)

 

four

 

times

 

and

 

OK

 

will

 

show

 

up

 

in

 

display.

  

 
 
 
 

Press

 

control

 

button

 

3

 

(OK)

 

to

 

get

 

into

 

4.5.1

 

Setup

.

  

 
 

Press

 

control

 

button

 

3

 

four

 

times

 

to

 

get

 

to

 

Cookerhood.

  

 

Press

 

control

 

button

 

4

 

(enter)

 

to

 

get

 

into

 

4.5.1.5

 

Cookerhood

 

menu.

 

 

Set

 

to

 

100%

 

from

 

factory.

 

 

Move

 

between

 

Supply

 

air

 

and

 

Extract

 

air

 

with

 

control

 

button

 

4.

 

Change

 

values

 

with

 

control

 

buttons

 

2

 

(

)

 

or

 

3

 

(+).

 

 

After

 

setting

 

press

 

control

 

button

 

1

 

(Return)

 

three

 

times

 

to

 

get

 

back

 

to

 

start

 

menu..

 

 

Here

 

the

 

values

 

for

 

Supply

 

air

 

and

 

Extract

 

air

 

should

 

be

 

set

 

to

 

same

 

values

 

as

 

for

 

MAX

 

in

 

menu

 

4.5.1.3.

 

Fan

 

control

 

in

 

the

 

user

 

manual

 

that

 

follows

 

this

 

unit.

 

 

If

 

an

 

active

 

kitchen

 

ventilator

 

is

 

used.

 

If

 

an

 

active

 

kitchen

 

ventilator

 

is

 

used,

 

then

 

Extract

 

air

 

should

 

be

 

set

 

to

 

50%

 

or

 

less

  

to

 

compensate

 

for

 

the

  

air

 

that

 

is

 

extracted

 

via

 

kitchen

 

ventilator.

 

Summary of Contents for AHU Series

Page 1: ...Startup procedure for Ensy AHU units ...

Page 2: ...re Overview push buttons 2 Control to see if there are contact between Display and Master software in unit Press control button 3 once to get into the information menu Press control button 3 once to get into the Program version menu Press Enter control button 4 You than will see that there are contact with Display and Mastercard software in menu picture 3 2 Latest display software are 021 and Mast...

Page 3: ...speed There are different values on MIN NORM and MAX depending on the unit type Factory settings you can find in User manuals and Installation Guide under menu 4 5 1 3 Fan control Press control button 3 to test the unit on MIN speed It is the value for supply air fan that shows in display If adjusted What is new value after installation Supp _____ Extr _____ Press control button 3 to test the unit...

Page 4: ...control button 3 OK to get into 4 5 1 Setup Press control button 3 twice to get to Fan control Press control button 4 enter to get into 4 5 1 3 Fan control menu There are different values on Min Normal and Max depending on the unit type Factory settings you can find in User manuals and Installation Guide under menu 4 5 1 3 If you need to do adjustments here to get balanced ventilation then please ...

Page 5: ...uttons 2 or 3 Press control button 4 once to get to next step If you need to go back and wants to correct a field you can start over by pressing control button 4 number of times till you are back in the field you need to change Write down date ________________ Press control button 3 OK once to get back to 4 Preferences menu Press control button 3 twice to get to Filter Press control button 4 once ...

Page 6: ...ignal can be taken from the cooker hood directly if possible or via a pressure switch in the exhaust piping from the ventilator Kitchen ventilator with integrated fan is not allowed to connect directly to the Cooker hood inlet on the ventilation unit For this you need to make its own exhaust piping through wall Anyway you need to make a signal from kitchen ventilator into KV connection plug on the...

Page 7: ...ay Press control button 4 enter four times and OK will show up in display Press control button 3 OK to get into 4 5 1 Setup Press control button 3 four times to get to Cookerhood Press control button 4 enter to get into 4 5 1 5 Cookerhood menu Set to 100 from factory Move between Supply air and Extract air with control button 4 Change values with control buttons 2 or 3 After setting press control ...

Page 8: ... documentation folder that shall follow the unit Other options that can be used together with the unit can be found in the instructions supplied unit All paperworks and instructions you can find on www ensy no The company that have installed this unit Contact ________________________________ _____________________________________ Phone e mail ________________________________ _______________________...