Ⅳ. Storage and Maintenance 

 

 

 

Storage 

 

Store the product in a dry, clean place when it will not be used for a long time. 

 

Keep  the  product  out  of  direct  sunlight  and  store  away  from  heat,  oil,  organic 
vapor and moisture. 

 

Pre-operation  is  required  to  obtain  the  battery  capacity  of  the  controller  when 
stored below 0℃. 

 

The  storage  temperature  is  suitable  between  -5℃  and+55℃,  relative,  and  please 
stored at relative humidity below 90%. 

 

Keep the mask, controller and charger away from moisture. 

 

 

Maintenance 

 

Check the product before using. 

 

Check  the  filter  regularly,  replace  it  with  a  new  one  if  the  filter  is  damaged  or 
contaminated by foreign objects. 

 

If there is not enough air supply, check and replace the filter. 

 

The  product  is  not  warranted if  problems  arise  from  cleaning  the  used filter  or 
removing contaminants through compressed air. 

 

If  you  need  to  wash  the  face  part  of  the  mask,  gently  wipe  the  household 
detergent with water and a clean patch. 

 

Silicon of face part of the mask can be detached or attached, and can be used 
after cleaning and drying. 

 

Do not use petroleum, organic solvents and abrasive cleaners. 

Used filters cannot be cleaned or reused. 

Be careful not to let water get into the body when cleaning. 

 

–  6  – 

Summary of Contents for DH-WAPM1

Page 1: ...DAEHYUNENTEC Wearable Air Purifier Mask User Manual Korean English ...

Page 2: ...CONTENTS Ⅰ Usage and Features of the Product 1 Ⅱ Cautions 2 Ⅲ Method for Usage 3 Ⅳ Storage and Maintenance 6 Ⅴ Product Configurations 8 Ⅵ Product Specifications 9 Product Warranty A S Application ...

Page 3: ...th a filter and air flow control for proper air supply to the user It prevents the inflow of harmful substance by generating a positive pressure so that outside air does not enter the mask It protects the user from the harmful substances in the air and ensures a softer breath than the yellowdust mask It also eliminates the discomfort caused by the moisture from when you breathe allowing for pleasa...

Page 4: ...y and the charging terminal directly This may cause a malfunction of device Checklist Check the cleaning status of the filter frequently Check that the filter is fitted correctly Check that the mask and controller are connected correctly Check for any abnormalities such as deformation tearing etc of the silicone part in contact with the face part of the mask Check that air is supplied to the face ...

Page 5: ...od When turning the power on Press the power button on the controller for 3 seconds Flow rate control When the power is turned on the flow starts at weak Each time the power button pressed the flow increased by one step from weak to middle and strong If you pressed power button again in the flow of strong it returns to weak When turning the power off Press the power button on the controller for 3 ...

Page 6: ...n the head strap place the entire face of the mask in front of your face and stick it behind your head to fit the face Adjust the length of hair strap to fit your face Make sure the mask is in close contact with your face hang it on your ears to prevent the mask from dripping and adjust the head strap Velcro type head strap Wear it so that the smooth side of the head strap touches your face If the...

Page 7: ...pressed If there is not remaining of battery it lights on red The fully charged controller can be used for 3 to 5 hours depending on the mask flow rate If you are using it for the first time or have not used it for more than 5 days please recharge it before reuse After removing the mask and controller charge the controller The controller takes about 3 hours to fully charged but the charging time d...

Page 8: ...oduct before using Check the filter regularly replace it with a new one if the filter is damaged or contaminated by foreign objects If there is not enough air supply check and replace the filter The product is not warranted if problems arise from cleaning the used filter or removing contaminants through compressed air If you need to wash the face part of the mask gently wipe the household detergen...

Page 9: ... clogged by foreign matter Check the filter and cover and replace the filter if there is a problem When operation does not stop The power was not turned off Press and hold the power button on the controller for 3 seconds When the operation time is short even when the controller is fully charged The controller battery has reached the end of its life Contact A S center The charger is defective Check...

Page 10: ... 1 Silicon holder 1 Rear body 1 Controller 1 Filter 1 Battery 1 Filter cover 1 Motor 1 Filter body 1 Charger 1 Filter inner cover 1 5 pin cable 1 Face silicon 1 Head strap Velcro type 1 Pass silicon 1 Head strap Buckle type 1 8 Filter and Face silicone can be purchased separately ...

Page 11: ...m Air flow rate Weak 100 L min Middle 120 L min Strong 140 L min Operational time Weak 5hr Middle 4hr Strong 3hr Operational temperature 5 55 Storage temperature 5 55 Weight Mask 178g Controller 95g Filter 10g Charger Cable Micro USB 5pin 220V C type cable Battery Li ion 12V 2600mA Filter HEPA filter H12 9 ...

Page 12: ...ranty period has passed or even if is within the warranty period repairs may be charged and charges may be incurred if breakdown or damage occurs due to careless handling of the consumer Repairs due to natural disasters accidents and disasters should be paid for The fault of A S will be decided by technician after determine the cause Please submit this warranty when repairing Manufacturer DAEHYUNE...