background image

ENTEGRIS, INC.

Customer Service Tel. 763-502-0200   Customer Service Fax 763-502-0300

13

NT® PRESSURE  T RAN SDUCER USE R  GUIDE

NT®  PRESSURE TRANSDUCER  USER  GUIDE

12

Customer Service Tel. 763-502-0200   Customer Service Fax 763-502-0300

ENTEGRIS, INC.

Troubleshooting the NT

®

Pressure

Transducers may be accomplished
by measuring the output signal of
the pressure transducer with a
battery powered current/voltage
meter. The meter may be placed in
series with the pressure transducer
to measure the current output or it
may be used to directly measure the
voltage output.

Using the battery powered current/
volt meter is an effective method to
determine whether the device or the
on-site data acquisition system is not
functioning properly.

Troubleshooting

The following lists the specifications
for NT

®

Pressure Transducers,

models 4150 and 4250. Consult the
factory for product specifications
manufactured for nonstandard 
applications.

NOTE:

Specifications are subject 

to change without notice. Please
consult the factory for the most
current information.

Reference

CONSTRUCTION MATERIALS

Wetted parts:

Body:

PTFE

Sensor Interface:

Sapphire 

O-Ring:

Kalrez

®

4079, Kalrez

®

1050 or Kalrez® 6375 UP

Nonwetted parts:

Polypropylene, polyethylene and PVDF 
(In addition to materials listed above)

Connection type:

Flaretek

®

Physical Specifications

Electrical Specifications

Input power:

24 VDC (12-28 VDC)

Pressure signal output ranges:

4-20 mA

Electrical connection:

6

, 12

, 30

FEP-coated pigtail or polypropylene 

3-pin connector with PVC cable

Reference accuracy:

±1% of span (includes linearity, hysteresis
and repeatability) at 73°F (23°C)

Process temperature:

50° to 95°F (10° to 35°C)

Performance Specifications

Summary of Contents for NT 4150

Page 1: ...0 Customer Service Fax 763 502 0300 www entegris com www entegrisfluidhandling com Entegris and Flaretek are registered trademarks of Entegris Inc NT is a registered trademark of NT International an Entegris Company Kalrez and Viton are registered trademarks of DuPont Dow Elastomers 2004 Entegris Inc Printed in USA P N 1088 Rev B 07 04 3960 1587MAX 0704 The materials integrity management company ...

Page 2: ...stallation 7 Power Supply Requirements 8 Load Resistance Current Output 9 Unit Operation 10 Operating Environment 10 Process Connections 10 Pressure Transducer Cover Assembly 10 Temperature Requirements 10 Pressure Limits 10 Pressure Reference Accuracy 10 Linear Output Signal 11 Troubleshooting 12 Reference 13 Physical Specifications 13 Electrical Specifications 13 Performance Specifications 13 Ce...

Page 3: ...ials Ordering Information CODE BASE MODEL 4150 Single Port Vacuum Pressure Transducer CODE PRESSURE RANGE 030V 12 to 30 PSIG 83 to 207 kPa 060V 12 to 60 PSIG 83 to 414 kPa 100V 12 to 100 PSIG 83 to 690 kPa CODE INLET OUTLET PORT CONNECTION TYPE F02 1 4 Flaretek F03 3 8 Flaretek F04 1 2 Flaretek N02 1 4 FNPT N04 1 2 FNPT M02 1 4 MNPT CODE ELECTRICAL CONNECTOR TYPE B06 FEP jacketed 6 pigtail electri...

Page 4: ...ials Ordering Information CODE BASE MODEL 4150 Single Port Vacuum Pressure Transducer CODE PRESSURE RANGE 030V 12 to 30 PSIG 83 to 207 kPa 060V 12 to 60 PSIG 83 to 414 kPa 100V 12 to 100 PSIG 83 to 690 kPa CODE INLET OUTLET PORT CONNECTION TYPE F02 1 4 Flaretek F03 3 8 Flaretek F04 1 2 Flaretek N02 1 4 FNPT N04 1 2 FNPT M02 1 4 MNPT CODE ELECTRICAL CONNECTOR TYPE B06 FEP jacketed 6 pigtail electri...

Page 5: ... SEAL U1 Kalrez 4079 Viton default U2 Kalrez 1050 Viton U3 Kalrez 6375 UP Viton S1 Kalrez 4079 Kalrez 4079 S2 Kalrez 1050 Kalrez 1050 S3 Kalrez 6375 UP Kalrez 6375 UP This User Guide applies to product manufactured as standard NT Pressure Transducers single port and flow through models 4150 and 4250 Entegris also manufactures nonstandard product to meet the needs of specific applications Nonstanda...

Page 6: ... SEAL U1 Kalrez 4079 Viton default U2 Kalrez 1050 Viton U3 Kalrez 6375 UP Viton S1 Kalrez 4079 Kalrez 4079 S2 Kalrez 1050 Kalrez 1050 S3 Kalrez 6375 UP Kalrez 6375 UP This User Guide applies to product manufactured as standard NT Pressure Transducers single port and flow through models 4150 and 4250 Entegris also manufactures nonstandard product to meet the needs of specific applications Nonstanda...

Page 7: ...white wire is not required please refer to the wiring diagram below Pressure transducer 4 20 mA output version 24 VDC GND RED WHITE BLACK 4 20 mA pressure signal no connection display or PLC Mechanical Installation NT Pressure Transducers utilize Flaretek flared tube connections and must be used with the proper tubing size and coupling nut When installing flared tubing to the pressure transducer t...

Page 8: ...white wire is not required please refer to the wiring diagram below Pressure transducer 4 20 mA output version 24 VDC GND RED WHITE BLACK 4 20 mA pressure signal no connection display or PLC Mechanical Installation NT Pressure Transducers utilize Flaretek flared tube connections and must be used with the proper tubing size and coupling nut When installing flared tubing to the pressure transducer t...

Page 9: ... resistance ohms typically not used therefore Rmeter 0 Rwire resistance of interconnecting wire RLoad Rmeter Rwire VPS 12 V 0 020A Operating region Power Supply Voltage VPS 12 24 28 800 0 The pressure transducer requires a 12 28 volt DC power supply with less than 2 ripple at 100 or 120 Hz The required power supply voltage varies with the load resistance RLoad please refer to the diagrams below an...

Page 10: ... resistance ohms typically not used therefore Rmeter 0 Rwire resistance of interconnecting wire RLoad Rmeter Rwire VPS 12 V 0 020A Operating region Power Supply Voltage VPS 12 24 28 800 0 The pressure transducer requires a 12 28 volt DC power supply with less than 2 ripple at 100 or 120 Hz The required power supply voltage varies with the load resistance RLoad please refer to the diagrams below an...

Page 11: ...arranty and damage the unit Temperature Requirements The pressure transducer is rated for use with fluids at process temperatures between 50 to 95 F 10 to 35 C under normal operating conditions Pressure Limits TRANSDUCER MAX PRESSURE LIMIT RANGE 73 F 23 C 12 to 30 PSIG 45 PSIG 83 to 207 kPa 310 kPa 12 to 60 PSIG 90 PSIG 83 to 414 kPa 621 kPa 12 to 100 PSIG 150 PSIG 83 to 690 kPa 1034 kPa WARNING T...

Page 12: ...arranty and damage the unit Temperature Requirements The pressure transducer is rated for use with fluids at process temperatures between 50 to 95 F 10 to 35 C under normal operating conditions Pressure Limits TRANSDUCER MAX PRESSURE LIMIT RANGE 73 F 23 C 12 to 30 PSIG 45 PSIG 83 to 207 kPa 310 kPa 12 to 60 PSIG 90 PSIG 83 to 414 kPa 621 kPa 12 to 100 PSIG 150 PSIG 83 to 690 kPa 1034 kPa WARNING T...

Page 13: ...ubleshooting The following lists the specifications for NT PressureTransducers models 4150 and 4250 Consult the factory for product specifications manufactured for nonstandard applications NOTE Specifications are subject to change without notice Please consult the factory for the most current information Reference CONSTRUCTION MATERIALS Wetted parts Body PTFE Sensor Interface Sapphire O Ring Kalre...

Page 14: ...ubleshooting The following lists the specifications for NT PressureTransducers models 4150 and 4250 Consult the factory for product specifications manufactured for nonstandard applications NOTE Specifications are subject to change without notice Please consult the factory for the most current information Reference CONSTRUCTION MATERIALS Wetted parts Body PTFE Sensor Interface Sapphire O Ring Kalre...

Page 15: ...M B 1 4 Flaretek 2 90 73 7 mm 0 99 25 2 mm 3 8 Flaretek 2 90 73 7 mm 1 06 26 9 mm 1 2 Flaretek 2 90 73 7 mm 1 14 29 0 mm ELECTRICAL CONNECTOR INFORMATION NT PRESSURE TRANSDUCER USER GUIDE 14 Customer Service Tel 763 502 0200 Customer Service Fax 763 502 0300 ENTEGRIS INC CE Compliance Entegris products have been tested to various test standards required by the EMC 89 336 EEC directive The results ...

Page 16: ...M B 1 4 Flaretek 2 90 73 7 mm 0 99 25 2 mm 3 8 Flaretek 2 90 73 7 mm 1 06 26 9 mm 1 2 Flaretek 2 90 73 7 mm 1 14 29 0 mm ELECTRICAL CONNECTOR INFORMATION NT PRESSURE TRANSDUCER USER GUIDE 14 Customer Service Tel 763 502 0200 Customer Service Fax 763 502 0300 ENTEGRIS INC CE Compliance Entegris products have been tested to various test standards required by the EMC 89 336 EEC directive The results ...

Page 17: ...ctor Connection Single port 3 00 76 2 mm Dim A Dim B Ø 1 88 47 8 mm 3 conductor connector cable DXX Cable length up to 30 feet WIRE 4 20 MA OUTPUT VERSION Black Ground 4 20 mA Red 24 VDC 4 20 mA White Not used INLET OUTLET PORT CONNECTION DIM A DIM B 1 4 Flaretek 2 90 73 7 mm 0 99 25 2 mm 3 8 Flaretek 2 90 73 7 mm 1 06 26 9 mm 1 2 Flaretek 2 90 73 7 mm 1 14 29 0 mm ELECTRICAL CONNECTOR INFORMATION...

Page 18: ...ctor Connection Single port 3 00 76 2 mm Dim A Dim B Ø 1 88 47 8 mm 3 conductor connector cable DXX Cable length up to 30 feet WIRE 4 20 MA OUTPUT VERSION Black Ground 4 20 mA Red 24 VDC 4 20 mA White Not used INLET OUTLET PORT CONNECTION DIM A DIM B 1 4 Flaretek 2 90 73 7 mm 0 99 25 2 mm 3 8 Flaretek 2 90 73 7 mm 1 06 26 9 mm 1 2 Flaretek 2 90 73 7 mm 1 14 29 0 mm ELECTRICAL CONNECTOR INFORMATION...

Page 19: ... 5 mm 0 73 18 5 mm 3 8 Flaretek 3 53 89 7 mm 3 87 98 3 mm 0 67 17 0 mm 1 2 Flaretek 3 78 96 0 mm 4 03 102 4 mm 0 85 21 6 mm 3 4 Flaretek 4 11 104 4 mm 4 27 108 5 mm 1 00 25 4 mm 1 Flaretek 4 43 112 5 mm 4 75 120 7 mm 1 20 30 5 mm 3 00 76 2 mm Dim A Dim B Ø 1 88 47 8 mm 3 conductor connector cable DXX Cable length up to 30 feet 4150 FEP jacketed Electrical Cable Connection Single port NPT Version W...

Page 20: ... 5 mm 0 73 18 5 mm 3 8 Flaretek 3 53 89 7 mm 3 87 98 3 mm 0 67 17 0 mm 1 2 Flaretek 3 78 96 0 mm 4 03 102 4 mm 0 85 21 6 mm 3 4 Flaretek 4 11 104 4 mm 4 27 108 5 mm 1 00 25 4 mm 1 Flaretek 4 43 112 5 mm 4 75 120 7 mm 1 20 30 5 mm 3 00 76 2 mm Dim A Dim B Ø 1 88 47 8 mm 3 conductor connector cable DXX Cable length up to 30 feet 4150 FEP jacketed Electrical Cable Connection Single port NPT Version W...

Page 21: ... SPECIAL INCIDENTALORCONSEQUEN TIALDAMAGES IMPLIED WARRANTIES OFMERCHANTABILITYANDFITNESS FOR A PARTICULARPURPOSEARE SPECIFICALLY DISCLAIMED Repair and warranty service is available at the Entegris factory To expedite the return and repair of the product contact Entegris at 877 503 0200 A Return Materials Authorization RMA number and a product packaging and return procedure will be provided at tha...

Page 22: ... SPECIAL INCIDENTALORCONSEQUEN TIALDAMAGES IMPLIED WARRANTIES OFMERCHANTABILITYANDFITNESS FOR A PARTICULARPURPOSEARE SPECIFICALLY DISCLAIMED Repair and warranty service is available at the Entegris factory To expedite the return and repair of the product contact Entegris at 877 503 0200 A Return Materials Authorization RMA number and a product packaging and return procedure will be provided at tha...

Page 23: ...0 Customer Service Fax 763 502 0300 www entegris com www entegrisfluidhandling com Entegris and Flaretek are registered trademarks of Entegris Inc NT is a registered trademark of NT International an Entegris Company Kalrez and Viton are registered trademarks of DuPont Dow Elastomers 2004 Entegris Inc Printed in USA P N 1088 Rev B 07 04 3960 1587MAX 0704 The materials integrity management company ...

Reviews: